Phone

    00852-6915 1330

switch Related Articles

Stay Ahead with Expert Electronics Insights,
Industry Trends, and Innovative Tips

Resistors

Electrical Relay: Relay Contact Overview

IntroductionThe relay is an electrical device regarded as a switch in the circuit. That is, the current in the control circuit depends on the "open" and "close" of relay contacts. Therefore, the reliability and service life of the relay depend on the quality and performance of the contacts greatly. The performance of the contact is affected by factors such as contact material, contact voltage, load type, operating frequency, atmospheric environment, contact configuration and bounce.  If any of these factors cannot meet the predetermined value, contact problems such as electrochemical corrosion of the metal between the contacts, contact welding, contact wear, and contact resistance may occur. The volume of the load determines the size of the voltage and current that the relay can control (The rated load of the contact refers to the voltage and current that the electromagnetic relay allows to break.). If you not pay attention to it when use, it is easy to damage the relay contacts.Relay ContactCatalogIntroductionⅠ Relay Contact Form ConfigurationⅡ Relay Contact SymbolⅢ Relay Contact Fault Analysis3.1 Terminology3.2 Contact Bonding and Fusion Welding3.3 Contact Erosion3.4 Contact Metal Migration3.5 Contact Loose and Crack3.6 Contact DustⅣ Contact Protection MethodsⅤ Frequently Asked Questions about Relay ContactⅠ Relay Contact Form Configurationa. Normally Opened ContactIt would mean the contacts are normally open when the coil of the relay is not energized or there is no magnetic field nearby in a reed switch. b. Normally Closed ContactIt would mean the contacts are normally closed when the coil of the relay is not energized or there is no magnetic field nearby in a reed switch. c. Common ContactIt would have 3 leads and would have one normally open and one normally closed circuit. This is also called a “changeover” because the common contact changes from the normally closed position to the normally open position when the coil is energized in a relay or a magnetic field is nearby in a reed switch. Ⅱ Relay Contact Symbol Ⅲ Relay Contact Fault Analysis3.1 TerminologyThere is something in which the relay contact seems to be closed, but the circuit works abnormally sometimes. This is due to the existence of the contact resistance of the relay contacts. When the current passes through the closed contact, the contact resistance will consume a certain amount of power, which will increase the temperature of the contact. If the current is large, the contact material will soften and deform, resulting in greater contact resistance, and even having welding failure in severe cases, making the closed contact unable to be disconnected. Another form of contact resistance is "membrane resistance". Because the contacts of the relay are exposed to the air for a long time, there will always be compounds produced by dust, water vapor, and chemical gas, which will adhere to the contacts to form a thin film. Because of it, the conductivity of the contacts will become worse, and even become non-conductive in severe cases. 3.2 Contact Bonding and Fusion WeldingContact bonding usually occurs when the contacts are in a static connection. Contact resistance making the temperature of the conductive spots and nearby materials increase, which leads to a great increase in the diffusion rate and a large expansion of the contact area. The molecular force formed by the mutual extrusion and penetration of metal molecules at the contact point is the internal factor leading to the contact bonding, in addition, the sliding friction between the contacts is a necessary condition for accelerating the molecular extrusion penetration and accumulating bonding force. The size of the bonding force depends on the rigidity of the contact material and the physical conditions that cause molecular extrusion and penetration. Whether the contacts are bonded depends on the bonding force is greater than the return force of the reed. Fusion welding refers to the phenomenon that the contact areas of two electrodes are united together by metal welding. According to the reasons for formation, welding can be divided into static welding and dynamic welding. The Joule heat generated by the contact resistor melts the contacts part, and the phenomenon that they are combined and cannot be disconnected is called static welding. In the process of the contacts controlling the external circuit, the contact pressure of the contacts is near zero or above, and meanwhile, the liquid metal bridge between the contacts made. The welding phenomenon that occurs owing to the arc heat flow melting the contacts is called dynamic welding. 3.3 Contact ErosionA load of contact switching is mostly inductive. When the inductive load is disconnected, its accumulated magnetic energy will generate a high back electromotive force at both ends of the contact, which will break up the air gap between the contacts to form sparks and cause electrical corrosion. Cause the contact surface to dent or stick and cannot be separated, all of them belong to poor contact, which will result in a short circuit. The main factors that affect arc erosion include the characteristics of the arc and its effect on the heat flow and force of the electrode and the response of the contact material to the heat and force of the arc. In general, there are two main forms of arc erosion: 1) Vaporization and evaporation: Under the action of arc energy, the surface material of the contact changes from solid to liquid, and then into a gaseous state to leave the contact. Except that, in certain conditions, the contact material also has a sublimation process from a solid-state to a gas state. 2) Liquid splashing: Under the action of arc energy, a certain area of the surface of the contact melts. The liquid metal splashes out in the form of tiny droplets under the action of various forces, resulting in a larger material loss. These forces include spot pressure, electrostatic field force, electromagnetic force, force and reaction force of material movement, contact surface tension, etc. The form of arc erosion varies with the contact material and load current conditions. When the load current is small, the erosion of the contact material is dominated by vaporization and evaporation. When the current is increased, not only the vaporization and evaporation of the contact material but also the splashing phenomenon of liquid metal will occur. When the current is further increased, the metal liquid splashing becomes the main form of contact erosion. Preventing electrical corrosion between the contacts can be obtained by setting up a resistance spark extinguishing circuit and a resistance-capacitance spark extinguishing circuit. Therefore, when choosing a relay, you should consider the voltage applied to the contact and the load capacity of the contact. For example a relay with a contact load of 28V(DC)×10A means that the relay’s contact can only work at a DC voltage of 28V, and the contact current is 10A. If these two ratings are exceeded, the service life of the relay will be affected, and even the contacts will be burnt and damaged. In addition, the number of circuits that the relay needs to control should be determined according to actual requirements. In the same model series of relays, there are generally a variety of contact forms for selection, and each group of contacts should be fully utilized when using. 3.4 Contact Metal MigrationDuring the working process, there is usually a mutual transfer of materials between two contacts. If this mutual transfer cannot be offset, a net transfer of materials occurs. The significant contact metal migration is a big net transfer. The asymmetry of various factors in the contact operation is the main reason for the metal migration of the contact. These factors include arc, contact material characteristics and various external forces. Details are as following: 1) The arc has various forms of energy input to the contacts. For the contact at the cathode, the kinetic energy of the ion current colliding with the cathode after being accelerated by decompression, the potential energy released by the ion current on the cathode surface and the electrons, the arc column radiation or the energy conducted to the cathode surface, and the cathode Joule heat generated by the current in the body. All of these energies will increase the temperature of the contact material, resulting in contact material melting and evaporation. 2) The contact has various forces in the working process, including electronic force, electrostatic force, electromagnetic force, the reaction force of material movement, plasma flow force, these forces may cause the metal in the molten pool on the surface of the contact Liquid splashing occurs. 3) The material properties that affect the migration of the contact metal include electrical conductivity, specific heat capacity, latent heat of melting and vaporization, melting point and boiling point, metallurgical dynamics, and so on. In addition, the size, shape, and connection form of the contacts will also affect the metal migration. 3.5 Contact Loose and CrackContacts are electrical contact parts for relays to switch loads. Some products have contacts that are press-fitted by riveting. The main drawbacks of this installing method are loose contacts, cracks in the contacts, or excessive size and so on. They will affect the contact reliability of the relay. The loosening of contacts is caused by the improper size of the mating part of the reed and the contact or the improper adjustment force by the operator. Contact cracking is caused by too high material hardness or too much pressure. Different crafts should be used for contacts of different materials, and some contact materials with higher hardness should be annealed before contact manufacturing, riveting, or welding. 3.6 Contact DustSometime after use, dust and dirt will deposit on the contacts of the relay, which will cause a black oxide film on the surface, resulting in poor contact. Therefore, the contacts need to be cleaned regularly. For example, carbon tetrachloride liquid can be used to ensure good contact performance.  Ⅳ Contact Protection MethodsFigure 1. Contact Oscillogram (contact action time, release time, rebound time and stabilization time)We know that the relay contact protection needs to be more careful than MOSFET. Generally, the load of the relay is much larger than MOSFET. Common DC motors, DC clutches and DC solenoid valves with large DC loads, these inductive load switches are often closed, because surges caused by hundreds of or even thousands of back electromotive force will shorten the life of the contacts or even completely damage them. On the contrary, if the current is small, such as around 1A, the back electromotive force will cause arc discharge, which will cause metal oxides to contaminate the contacts, leading to failure of the contacts and increasing contact resistance. Protect contacts mainly to extend the use time of the relay, because the contacts will always accumulate carbon and age, and the surface is not as clean as it was originally. What’s more, when the relay life is approaching the end, its contact resistance will increase rapidly. Generally, under normal temperature and pressure, the breakdown voltage of the key dielectric in the air is 200~300V. Therefore, our goal is generally to control the voltage below 200V or less.Figure 2. Breakdown VoltageThere generally have the following methods to do it:MethodCircuitCharacteristicComponent SelectionResistor and CapacitorIf the load is related to time, the initial leakage current may cause the load to malfunction.R: The contact voltage is 1VC: The contact current is 1A, and the value of RC varies with the relay and load.The function of the capacitor C is to suppress the excessive voltage when the inductor is discharged.The value of resistance R is determined by the test needs.The breakdown voltage of the capacitor C is 200~300V.If the load is a relay or solenoid valve, the release time will be extended. When the contact power supply voltage range is 24V~ 48V, the voltage across the load is 100 ~ 200V.DiodeThe diode (regarded as a freewheeling diode) acts as a channel for the coil to release energy and a way to dissipate heat. Compared with the RC circuit, it significantly changes the release time of the relay (2~5 times).The reverse breakdown voltage is at least 10 times the power supply voltage, and the forward current is equivalent to the load.Zener DiodeThis circuit effectively prevents the diode from affecting the release time of the relay.The breakdown voltage of the Zener diode must be consistent with the power supply voltage of the relay.VaristorBased on the characteristics of the varistor to stabilize the voltage, this circuit can prevent the contact voltage from being too high, and also slightly delay the relay release time. When the load contact power supply voltage is 24V or 48V, and the voltage across the load is 100 to 200V, the varistor is very effective. * Standard diodes can significantly extend the rebound time. Connecting conventional diodes in series with Zener diodes will affect it lightly. If it is an inductive load, when the contacts are separated, a longer rebound time prolongs the arc generation time and shortens the life of the contacts. For example, a relay with a diode connected to the coil needs 9.8ms to release the contact. Combining the Zener diode with the small signal diode can shorten the time to 1.9ms. In addition, the return time of the relay without a diode connected to the coil is 1.5ms. Although the inductive load is not easy to handle than the resistive load, the use of effective protection will make the performance better. There are two methods that can’t be used.Figure 3. Capacitor and Relay CircuitIn the actual circuit, the protection device (diode, resistor, capacitor, varistor, etc.) and the load should have a certain distance. If the two are too far apart, the effect of the protective device may be weakened. Generally, the distance between the two should be within 50cm. DC loads at higher frequencies will cause abnormal switch corrosion (electric spark generation). When the DC solenoid valve or clutch is controlled at a higher frequency, the contacts may have corrosion. The reason for this is that when an electric spark (arc discharge) is generated, the reaction between nitrogen and oxygen causes contact corrosion. Ⅴ Frequently Asked Questions about Relay Contact1. How do relay contacts work?A relay is an electrically operated switch. They commonly use an electromagnet (coil) to operate their internal mechanical switching mechanism (contacts). When a relay contact is open, this will switch power ON for a circuit when the coil is activated. 2. What is a relay contact output?A relay contact output works basically like an on/off switch. To simplify, if the output is "off" the circuit will be broken (open). If the output is "on" the contact will be made, completing the circuit. Therefore, the controller does not supply any current or voltage itself. 3. Why do relay contacts weld?Consequently, when the contacts are ON again, short-circuited current from the capacitance may cause contact weld. This circuit effectively suppresses arcs when the contacts are OFF. When the contacts are ON again, however, charge current flows to the capacitor, which may result in contact weld. 4. How do I protect my relay contacts?Various ways to protect relay contacts from the effects of switching an inductive load – from left to right: a diode, a spark quench capacitor, Zener diodes or a transil, a varistor. 5. What is a contact form relay?Contact Form: The arrangement of the contacts in the relay. This determines how many circuits the relay can operate. Form 1A (or “1 Form A): One circuit is opened and closed with the contacts in a Normally Open position. 6. What is a relay contact?Relays control one electrical circuit by opening and closing contacts in another circuit. ... When a relay contact is Normally Closed (NC), there is a closed contact when the relay is not energized. In either case, applying electrical current to the contacts will change their state. 7. How many contacts does a relay have?Two. A simple electromagnetic relay consists of a coil of wire wrapped around a soft iron core, an iron yoke that provides a low reluctance path for magnetic flux, a movable iron armature, and one or more sets of contacts. 8. What is the difference between relay and contactor?A contactor joins 2 poles together, without a common circuit between them, while a relay has a common contact that connects to a neutral position. Additionally, contactors are commonly rated for up to 1000V, while relays are usually rated to the only 250V. 9. What is the purpose of contactor or relay?A contactor is a large relay, usually used to switch current to an electric motor or another high-power load. Large electric motors can be protected from overcurrent damage through the use of overload heaters and overload contacts. 10. What are the three major parts of a contactor or relay?There are three major parts of a contactor or relay: the coil, mechanical linkage and contacts. The coil is used to create a magnetic field and is rated based on voltage (24 V, 120 V, 208/204 V, 480 V). The mechanical linkage connects the armature to the contacts when the coil is energized, completing the circuit. Recommended ReadingBasic Knowledge of Relay Electronics Tutorial with VideoThe Role of the Relay and Its Working PrincipleHow Relays Work? Relay Functions and Applications
kynix On 2020-08-12   13124
Resistors

How to Test a Relay with Multimeter?

IntroductionA relay is an electronic control device, which has a control system (also called an input loop) and a controlled system (also called an output loop). It is often used in automatic control circuits. In fact, it is an automated switch using a smaller current to control a larger current. Therefore, it plays the role of automatic adjustment, safety protection, and converter in the circuit. Relay has the features of fast response speed, stable work, long service life and small size. In order to ensure that these performances can be better played, the test and maintenance of the relay (solid state relay) are particularly important. This paper will introduce main relay test parameters, how to test a relay, an example of an automotive relay test.Testing a RelayCatalogIntroductionⅠ Understanding Relays  1.1 Relay ParametersⅡ How to Test A Relay?  2.1 General Test Ideas  2.2 Types of Relay TestⅢ Relay for Life: Automotive Relay Test  3.1 Automotive Relay  3.2 Common Faults of Automotive Relays  3.3 Detection Method  3.4 Specific OperationⅣ One Question Related to Relay Test and Going Further  4.1 Question  4.2 AnswerⅤ Frequently Asked Questions about Relay TestⅠ Understanding Relays1.1 Relay ParametersMain relay parameters include rated working voltage, rated working current, coil resistance, contact load, etc.1) Rated working voltage refers to the voltage required by the coil when the relay is working normally. For DC relays it refers to DC voltage (Figure a), and for AC relays it refers to AC voltage (Figure b). Relays of the same type often have multiple assessed operating voltages for circuit requirements, and the specification number is added to the end of the component to distinguish.Figure 1. Relay Symbol2) The rated working current refers to the current required by the coil when the relay is working normally.Coil resistance refers to the DC resistance of the relay coil. When selecting a relay, you must ensure that it is rated working voltage and rated working current meet the requirements.Figure 2. Rated Working Current3) Contact load refers to the load capacity of the relay contact, also known as the contact capacity. For example, the contact load of the jzx-10m relay is:  DC 28v×2a or AC 115v×1a. When used, the voltage and current passing through the relay contact should not exceed the rated value, otherwise, the contact will be burned out and the relay will be damaged. A load of multiple sets of contacts of a relay is generally the same.Figure 3. Contact LoadRecommended Reading: Basic Knowledge of Relay Electronics Tutorial with Video    The Role of the Relay and Its Working Principle Ⅱ How to Test A Relay?Relays are widely used in power protection, automation, sport, remote control, measurement and communication devices, so it is very important to check and maintain the normal operation of relays. There are many types of relays. Therefore, the inspection of relays cannot only be judged by measuring the resistance value of the coil. It is necessary to adopt multiple detection methods according to different relay types.2.1 General Test Ideas1) measuring contact resistanceApply the specified working voltage to the relay coil, and use a multimeter to detect the on-off condition of the contact at the “R×1k” gear. When the power is not applied, the normally open contact does not work, and the normally closed contact conducts. When the power is turned on, you should be able to hear the pick-up sound of the relay. At this time, the normally open contact is conducting and the normally closed contact is opposite, and the switching contact should be switched accordingly. Otherwise, the relay is damaged. For multi-group contact relays, if some of the contacts are damaged, the remaining contacts can still be used.Figure 4. Relay Test 2) measuring coil resistanceThe resistance value of the relay coil can be measured with the multimeter at R×10Ω gear, so as to determine whether the coil is open. 3) measuring of pull-in voltage and currentUse an adjustable regulated power supply to input a set of voltage to the relay, and connect an ammeter in the power supply circuit to monitor. Increase the power supply voltage slowly, and when you hear the pull-in sound of the relay, write down the voltage and current. In order to be accurate, you can try several times to get the average value. 4) measuring the release voltage and currentSame test connection like the above. When the relay pulls in, then gradually reduce the supply voltage. When you hear the relay release sound again, write down the voltage and current at this time. Try several times to get the average release voltage and release current. Under normal circumstances, the release voltage of the relay is about 10-50% of the pull-in voltage. If the release voltage is too small (less than 1/10 of the pull-in voltage), it can't be used normally, which will affect the circuit stability resulting in abnormal operation. 2.2 Types of Relay TestElectromagnetic Relay TestFigure 5. Electromagnetic RelayThe multimeter is placed in the “R×100” or “R×1k” gear, and the two test leads (regardless of positive and negative) are connected to the two pins of the relay coil (shown in Figure 5). The indication of the multimeter should basically match the coil resistance of the relay. If the resistance value is obviously too small, it means that the coil is short-circuited locally; if the resistance value is 0, it means that there is a short circuit between the two coil pins; if the resistance value is infinite, it means that the coil is open or the pins are disconnected. Reed Relay TestReed relay is also one of the most commonly used relays. It consists of a reed switch and a coil, as shown in Figure 6. The reed switch is made by sealing two non-interconnected ferromagnetic metal strips in a glass tube, and the reed switch is placed in the coil. When the current passes through the coil, the magnetic field generated by the coil magnetizes the metal strips in the reed pipe, and the two metal strips attract due to opposite polarities to connect the controlled circuit. Several reed pipes can be placed in the coil, and they will act simultaneously under the action of the coil's magnetic field.Figure 6. Reed Relay Reed relay has a pair of coil pins and several pairs of reed switch pins, and there are corresponding marks on the shell for identification.Figure 7. Reed Relay Reed relays can also use a multimeter to detect their coils and contacts, and the detection method is the same as that of electromagnetic relays.Figure 8. Reed Relay Solid State Relay (SSR) TestThe input end can be tested with a multimeter. The multimeter is placed in the "R×10k" gear, the black test lead (the positive electrode of the battery in the meter) is connected to the positive electrode of the SSR input terminal, and the red test lead (that is, the negative electrode of the battery in the meter) is connected to the negative electrode of the input terminal of SSR. The hands should deflect more than halfway (Figure 9). Re-testing after swapping the two test leads, the hands should not move. If the needle deflects to the top or does not move regardless of the forward or reverse voltage access, the solid-state relay has been damaged.Figure 9. Solid State Relay  SSR You can also make a test circuit according to Figure 10. When the control voltage of the SSR input terminal is turned on, the light-emitting VD is on; when the control voltage of the SSR input terminal is cut off, the light-emitting diode VD is off.Figure 10. SSR Thermal Relay Test1) heating elements detectionThe heating element is composed of an electric heating wire or electric heating sheet, and its resistance is very small (close to 0Ω). The detection is shown in Figure 11. The normal resistance of the three groups of heating elements should be close to 0Ω. If the resistance is infinite (the digital multimeter displays the symbol "1" or "OL" for exceeding the range), the heating element is open.Figure 11. ① 200Ω gear is selected.② The red and black probes are respectively connected to the two ends of a heating element.③ The resistance is close to 0Ω, indicating that the resistor as a heating element is normal. 2) contact detectionThermal relays generally have a normally closed contact and a normally open contact. This detection includes working and non-working conditions. The first picture is the detection of the normally closed contact resistance when it is not in operation. Normally it should be close to 0Ω. Then the detection is taken in the opposite condition. Move the test rod, as shown in the second picture, simulates the over-current heating and bending of the heating element to make the contact action. The normally closed contact becomes an open circuit, and the resistance is infinite.Figure 12. ① 200Ω gear is selected.② The red and black probes are connected to both ends of the normally closed contact.③ The resistance is close to 0 Ω, indicating that the normally closed contact is closed.④ Move the test rod by hand.⑤ The out-of-range symbol "1" is displayed to indicate that the normally closed contact is open. Intermediate Relay TestThe electrical part of the intermediate relay is composed of coils and contacts, both of which use the resistance gear of a multimeter.1) The contact is detected when the control coil is not powered. Contacts include normally open contacts and normally closed contacts. When the control coil is power off, the normally open contacts are open and the resistance is infinite, at this time, the normally closed contacts are closed and the resistance is close to 0Ω. The above-mentioned detection of the normally open contact is shown in the figure below.Figure 13.① 200Ω gear is selected.② The red and black probes are connected to both ends of normally open contact.③ The out-of-range symbol "1" is displayed to indicate that the normally open contact is open. 2) Control coil detection of the intermediate relay is shown in Figure 14. Generally, the greater the rated current of the contact, the smaller the resistance of the control coil. This is because the greater the rated current of the contact, the larger the volume of the contact. Only a small control coil resistance (thicker line diameter) can flow through a larger current to produce a stronger magnetic field suction contact.Figure 14. ① 200Ω gear is selected for the gear switch.② Connect the red and black lead to the two pins of the control coil.③ The display of "6.60" indicates that the resistance of the control coil is 6.6kΩ.3) Power on the control coil to detect the contacts. Apply a rated voltage to the control coil, then use a multimeter to detect the resistance of the normally open and normally closed contacts. The normally open contact should be closed and the resistance should be close to 0Ω; the normally closed contact should be open and the resistance is infinite. Time Relay TestThe detection of time relay mainly includes contact normal state detection, coil detection and coil energization detection.1) Normal-state detection of contacts. It refers to the detection of the resistance of the contact when the control coil is not energized. The normally open contact is open and the resistance is infinite, while the normally closed contact is closed, and the resistance is close to 0Ω. Normal detection processes are shown in the figure below.Figure 15. ① 200Ω gear is selected for the gear switch.② The red and black lead is connected with two pins of a normally closed contact.③ The resistance is close to 0Ω, indicating that the normally closed contact is closed. 2) Detection of control coil. It is shown in Figure 16.Figure 16. ① 20kΩ gear is selected for the gear switch.② Connect the red and black lead to the two pins of the control coil.③ The display of "4.93" indicates that the resistance of the control coil is 4.93kΩ.3) Power on the control coil to detect the contacts. Apply a rated voltage to the control coil, then check whether the contact status has changed according to the characteristics of types of the time relay. For example, for a delay time relay, after a period of time delay, check whether the delay contact is closed (resistance is close to 0Ω) and whether the delay contact is disconnected (resistance is infinite).  Ⅲ Relay for Life: Automotive Relay Test3.1 Automotive RelayRelays are widely used in automotive circuits, such as starting system circuits, wiper circuits, and rear window heating circuits. When the vehicle starts, a larger starting current is required. If the ignition switch is used for direct control, the starting contacts will ignite and burn, which will affect the service life of the ignition switch and even cause serious consequences such as line ablation and fire. Using a relay to control a large current with a small current will not cause the above problems. When a certain voltage or current is applied to both ends of the electromagnetic relay coil, the magnetic flux generated by the coil passes through the magnetic circuit composed of the core, yoke, armature, and the working air gap of the magnetic circuit. Under the action of the magnetic field, the armature attracts the pole face of the iron core, making the normally closed contact opens and the normally open contact close. When the voltage or current at both ends of the coil is less than a certain value, the mechanical reaction force is greater than the electromagnetic attraction force, and the armature returns to the initial state: the normally closed contact is on and the normally open contact is off. One of the automobile relays functions is a switch; the other is load overload protection; the third is fault protection. 3.2 Common Faults of Automotive RelaysIncluding coil burnt, short circuit, insulation part aging, contact ablation, etc.1) Relay MalfunctionWhen the controlled circuit is required to be closed, the relay will not act, on the contrary, when the controlled circuit is not required to be closed, the relay will act. This kind of problem occurs mainly because the interference voltage in the circuit exceeds the allowable range of the drive circuit of the relay. When designing the circuit, pay attention to the factors that can cause interference (such as chip command errors, short circuits, grid fluctuations, etc.). 2) Relay BurnedThere are many reasons for burnout. For example, the actual switching current exceeds the rated switching current of the relay, and the actual inrush current exceeds the rated switching current of the relay. According to design experience, in order to avoid these problems, the rated current should be selected to be 2-3 times the actual switching current, and the impact current of the relay is 2-3 times the actual current. 3) Contact WeldingGenerally speaking, the temperature rise of the AC conversion relay coil is higher than that of the DC conversion relay. This is because of the eddy current loss and hysteresis loss in the magnetic circuit. In addition, when the AC conversion relay is operating at a voltage lower than the rated voltage, a bounce phenomenon may occur. This will cause burnout, welding of contacts and damage to the relay, or disconnection of the self-protection circuit. Therefore, measures must be taken to prevent fluctuations in the power supply voltage.In addition, regardless of the length of the fluctuation time, it will cause the failure of the relay. So ensure that there is a power supply with sufficient capacity. 4) Coil Temperature Rise is Too HighThe loss of magnetic materials such as copper wires and iron cores or the heat transfer of the contacts will cause the temperature rise. Therefore, the heat resistance of the insulating material and the distance between the relay and the heat-generating device should be paid special attention in the circuit design. 3.3 Detection MethodStatic detection: check the resistance of the coil and the resistance of the normally closed contact.Dynamic detection: energize the coil and detect the resistance of the normally open contact. 3.4 Specific OperationTurn on the ignition switch and hear whether there is a pull-in sound in the control relay or feel the relay with your hands for vibration. If so, it means that the relay is basically in routine. The failure of the circuit may be caused by other reasons. On the contrary, it means that the relay is faulty.Replace the relay to be tested with an identical working relay. Turn on the switch, and if the electrical equipment is working normally, it can be determined there is a problem with the relay to be tested.Use the multimeter Rx100Ω gear and combine the resistance of each pin of the circuit to analyze. If the conduction and disconnection are normal, it means that there is no problem with the relay, otherwise, it means the relay is faulty.Open the relay shell to check whether the contacts are ablated or oxidized. If there are bumps and rust on the contact, it means that the contact is ablated or oxidized and does not work properly.Check whether the coil is ablated or discolored. If the coil is ablated with jelly, the coil is black or has a gluey smell, which means the coil is short-circuited by ablation.Ⅳ One Question Related to Relay Test and Going Further4.1 QuestionWhat are the symptoms of a bad car relay?4.2 AnswerThe car suddenly stalls while operating. One of the most common symptoms of a failed ignition relay is a car that suddenly stalls while operating. Car not starting. Another symptom of a faulty ignition relay is a no-power condition.Dead battery. A dead battery is another symptom of a faulty ignition relay.Burned relay. Ⅴ Frequently Asked Questions about Relay Test1. How do you check if a relay is bad?The only tool required to check a relay is a multimeter. With the relay removed from the fuse box, the multimeter set to measure DC voltage and the switch in the cab activated, first check to see if there are 12 volts at the 85 positions in the fuse box where the relay plugs in (or wherever the relay is located). 2. How do you test a 12-volt relay? 3. How do you check an overload relay with a multimeter?CEP7 Overload Relay test proceduresMeasure the normal motor running current (i motor).Turn off the motor and let it cool for about 10 minutes.Calculate the following ratio: i (motor) / i (overload min FLA).Set the overload to its minimum FLA and turn on the motor.Wait for the overload to trip. 4. How do I test a solid-state relay?The SSR can be tested as described below if a load is connected. Connect a load and power supply, and check the voltage of the load terminals with the input ON and OFF. The output voltage will be close to the load power supply voltage with the SSR turned OFF. 5. Can a bad relay drain your battery?Battery drain or dead batteryA failed ECM power relay can also cause a battery drain or a dead battery. If the relay shorts, it can leave power on to the computer, even when the vehicle is turned off. This will place a parasitic drain on the battery, which will eventually cause it to go dead. 6. What happens when the main relay goes bad?The engine will not startIf the main relay is not supplying the engine computer with the power it needs, then the engine will not be able to crank and run the right way. Failing to get the main relay replaced will usually lead to the car being unusable. 7. How do you test a battery relay? 8. How do you test a protection relay?Protection relay self-test procedureThis will normally involve checking the relay watchdog circuit, exercising all digital inputs and outputs and checking that the relay analog inputs are within calibration by applying a test current or voltage. 9. How do you check if a relay is working?The only tool required to check a relay is a multimeter. With the relay removed from the fuse box, the multimeter set to measure DC voltage and the switch in the cab activated, first check to see if there are 12 volts at the 85 positions in the fuse box where the relay plugs in (or wherever the relay is located). 10. How do you test an electromagnetic relay?Grab a multimeter and set it to Ohms. Touch the leads across the electromagnet coil pins and measure resistance. Anywhere from 50-120 ohms is OK. Out of range or open means a bad electromagnet coil winding and time for a new relay.
kynix On 2020-07-29   15453
Resistors

Thermal Relay

IntroductionThermal relay is a protective device.  are protective devices. It is used in conjunction with a contactor to protect electric motors. The basic working principle of thermal relay is that, when a bimetallic strip is heated up by a heating coil carrying over current of the system, it bends and makes normally open contacts. Getting to know more about the thermal basics just check the following note. CatalogIntroductionⅠ The Working Principle and Structure of Thermal Relay  1.1 The Role and Classification of Thermal Relay  1.2 Protection Characteristics and Working Principle of Thermal RelayⅡ Selection and Setting Principle of Thermal Relay  2.1 Thermal Relay Selection Overview  2.2 Type Selection of Thermal Relay  2.3 Selection of Rated Current of Thermal Relay  2.4 Selection of Thermal Element Setting Current  2.5 Reliable and Reasonable Protection Characteristics of The Thermal Relay  2.6 Other ConsiderationsⅢ Other Matters Needing Attention  3.1 Installation Direction  3.2 Selection of Connecting Wires  3.3 Use Environment  3.4 Adjustment of Thermal RelayⅣ Frequently Asked Questions about Thermal RelayⅠ The Working Principle and Structure of Thermal Relay1.1 The Role and Classification of Thermal RelayIn the electric drag control system, when the three-phase AC motor runs under abnormal conditions such as long-term under-load and under-voltage operation, long-term overload operation, and long-term single-phase operation, it will cause the motor winding to overheat and even burn out. In order to give full play to the overload capacity of the motor, to ensure the normal start and operation of the motor, and once the motor is overloaded for a long time, it can automatically cut off the circuit, so that there are electrical appliances that can change the operating time with the degree of overload and that is thermal relay.  Obviously, the thermal relay is used for overload protection of the three-phase AC motor in the circuit. It must be pointed out that, due to the thermal inertia of the heating elements in the thermal relay, instantaneous overload protection cannot be done in the circuit, and short circuit protection cannot be done either. Therefore, it is different from overcurrent relays and fuses. According to the number of phases, there are three types of thermal relays: single-phase, two-phase, and three-phase. Each type has different specifications and model numbers according to the rated current of the heating element. Three-phase thermal relays are often used in three-phase AC motors for overload protection. Divided by function, there are two types of three-phase thermal relay. One is without phase failure protection and the other one is with phase failure protection.1.2 Protection Characteristics and Working Principle of Thermal Relay1) Protection Characteristics of Thermal Relay Because the contact action time of the thermal relay is related to the overload of the motor being protected, before analyzing the working principle of the thermal relay, the relationship between the motor's overload current and the motor's energizing time must be clarified under the condition that the motor does not exceed the allowable temperature rise. This relationship is called the overload characteristic of the motor. When an overload current occurs during the motor operation, it will inevitably cause the winding to heat up. According to the thermal equilibrium relationship, it is not difficult to draw the conclusion that under the condition of allowable temperature rise, the motor energizing time is inversely proportional to the square of its overload current. According to this conclusion, it can be concluded that the motor's overload characteristics have inverse time characteristics, as shown by curve 1 in Figure 1. Figure 1. Overload Characteristics of the Motor and Protection Characteristics of the Thermal Relay and Their Coordination In order to adapt to the overload characteristic of the motor and play the role of overload protection, it is required that the thermal relay should also have the inverse time characteristic as the motor overload characteristic. For this reason, the thermal relay must have a resistance heating element. The thermal effect generated by the overload heating current through the resistance heating element causes the sensing element to act, thereby driving the contact to complete the protection function.  The relationship between the overload current passed in the thermal relay and the action time of the thermal relay contact is called the protection characteristic of the thermal relay, as shown by curve 2 in figure 1. Considering the effects of various errors, the overload characteristics of the motor and the protection characteristics of the relay are not a curve, but a belt. Obviously, the larger the error, the wider the belt; the smaller the error, the narrower the belt. It can be known from the curve 1 in the figure that when the motor is overloaded, it is safe to work below the curve 1. Therefore, the thermal relay's protection characteristics should be close to the motor's overload characteristics. In this way, if an overload occurs, the thermal relay will operate before the motor reaches its allowable overload limit, cutting off the power to the motor to prevent damage. 2) Working Principle of Thermal Relay The heat-generating heating element in the thermal relay should be connected in series with the motor circuit. In this way, the thermal relay can directly reflect the overload current of the motor. The sensing element of a thermal relay generally uses a bimetal. The so-called bimetallic sheet is to mechanically roll two metal sheets with different linear expansion coefficients into one body. The larger the expansion coefficient is called the active layer, the smaller the expansion coefficient is called the passive layer. The bimetallic sheet undergoes linear expansion when heated. Because the linear expansion coefficients of the two layers of metal are different and the two layers of metal are closely attached together, the bimetallic sheet is bent to the passive layer side, and the mechanical force generated by the bending of the bimetallic piece drives the contact action. There are four types of bimetal heating methods, namely direct heating, indirect heating, composite heating, and current transformer heating. The direct heating type uses the bimetal as a heating element and allows current to pass through it directly; the heating element of the indirect heating type is made of resistance wire or tape, is wound around the bimetal and is insulated from the bimetal; the composite heating type is between the above two methods; the heating element of the current transformer heating type is not directly connected to the motor circuit, but is connected to the secondary side of the current transformer. This method is mostly used in situations where the motor current is relatively large to reduce the current passes through the heating element. Figure 2. Structural Schematic of the Thermal Relay The thermal element 3 is connected in series to the motor stator winding, and the motor winding current is the current flowing through the thermal element. When the motor is running normally, although the heat generated by the thermal element can bend the bimetal 2, it is not enough to make the relay operate; when the motor is overloaded, the heat generated by the thermal element increases, causing the bending displacement of the bimetal to increase.  After a certain period of time, the bimetal is bent to push the guide plate 4, and the contacts 9 and 6 are separated by the compensating bimetal 5 and the push rod 14, the contacts 9 and 6 are normally-closed contacts in which the thermal relay is connected to the contactor coil circuit, and the contactor is de-energized after being disconnected. The normally-open contacts of the contactor disconnect the power supply of the motor to protect the motor. The adjusting knob 11 is an eccentric wheel, which constitutes a lever with the support 12, and 13 is a compression spring. Turning the eccentric wheel and changing its radius can change the contact distance between the compensating bimetal 5 and the guide plate 4 so that the purpose of adjusting the setting action current is achieved. In addition, the position of the normally-open contact 7 is changed by adjusting the reset screw 8 so that the thermal relay can work in two working states: manual reset and automatic reset. When debugging the manual reset, after the fault is excluded, button 10 must be pressed to restore the movable contact to the contact position of the static contact 6. 3) Thermal Relay with Open Phase Protection One of the main reasons for a three-phase asynchronous motor to burn out is that wiring of a three-phase motor is loosened or a phase fuse is blown. If the motor protected by the thermal relay is Y connection method when one phase power failure occurs in the line, the current of the other two phases will increase a lot. Since the line current is equal to the phase current, the current flowing through the motor windings and the current flowing through the thermal relay are increased by the same proportion, so ordinary two-phase or three-phase thermal relays can protect this.  If the motor is △ connection method, the phase current and line current of the motor will not be the same when the phase failure occurs, the current flowing through the motor windings and the current flowing through the thermal relay will increase in different proportions, and the thermal element is connected in series with the power supply line of the motor, and it is set according to the rated current of the motor, that is, the line current, and the setting value is relatively large. When the fault line current reaches the rated current, in the motor winding, the fault current of the phase winding with the larger current will exceed the rated phase current, and there is a danger of overheating and burning. Therefore, the △ connection method must use a thermal relay with phase failure protection. The thermal relay with phase failure protection is a differential mechanism added to the ordinary thermal relay to compare the three currents. The structural principle of the differential phase-open protection device is shown in figure 3. The guide plate of the thermal relay is changed to a differential mechanism, which is composed of an upper guide plate 1, a lower guide plate 2 and a lever 5. They are connected by a rotating shaft. Figure 3a shows the positions of the components of the mechanism before power is applied. Figure 3b shows the position during normal energization. At this time, the three-phase bimetals are bent to the left by heating, but the bending deflection is not enough. Therefore, the lower guide plate is moved to the left for a short distance, and the relay does not operate. Figure 3c shows the situation when the three phases are overloaded simultaneously. The three-phase bimetal is bent to the left at the same time, and the lower guide plate 2 is pushed to move to the left. The normally-closed contact is immediately measured by lever 5. Figure 3 shows the disconnection of phase C.  At this time, the phase C bimetal gradually cools down, the end moves to the right and pushes the upper guide plate 1 to the right. While the temperature of the other two-phase bimetals rises, the ends are bent to the left, pushing the lower guide plate 2 to continue to move to the left. Because the upper and lower guide plates move left and right, a differential function occurs, and the normally-closed contacts are opened by the amplification of the lever. Due to the differential function, the thermal relay is accelerated to protect the motor when the phase failure occurs. Figure 3. Schematic Diagram of Differential Relay Phase Failure Protection Mechanism of Thermal Relay Ⅱ Selection and Setting Principle of Thermal Relay2.1 Thermal Relay Selection OverviewThe thermal relay is mainly used to protect the motor from overload. In order to ensure that the motor can obtain both necessary and sufficient overload protection, it is necessary to fully understand the performance of the motor, and assign it with a suitable thermal relay to perform the necessary settings. Generally, conditions related to the motor are the working environment, starting current, load nature, working system, allowable overload capacity and so on. In principle, the ampere-second characteristic of the thermal relay should be as close as possible or even overlap the motor's overload characteristic, or under the motor's overload characteristic, and at the same time, the thermal relay should not be affected (not actuated) at the moment when the motor is temporarily overloaded and started. The correct selection of the thermal relay is closely related to the working system of the motor. When the thermal relay is used to protect the motor for long-term or intermittent long-term operation, it is generally selected according to the rated current of the motor. For example, the setting value of the thermal relay may be equal to 0.95-1.05 times of the rated current of the motor, or the median value of the setting current of the thermal relay is equal to the rated current of the motor, and then adjust. When the thermal relay is used to protect a motor that is repeatedly operated for a short time, the thermal relay has only a certain range of adaptability. If there are many operations per hour, a thermal relay with a speed saturation current transformer must be selected. For special working motors with frequent forward and reverse phase on and off, it is not appropriate to use thermal relays as overload protection devices. Instead, use temperature relays or thermistors embedded in the motor windings to protect them.2.2 Type Selection of Thermal RelayThe thermal relay can be divided into the two-pole types and three-pole types from the structural type. The three-pole type is divided into phase-open protection and no phase-open protection, which should be selected according to the stator wiring of the protected motor. When the motor stator winding is in delta connection, a three-pole thermal relay with phase failure protection must be used; for a motor using the star connection method, a thermal relay without phase failure protection is generally used. Because the general motor does not have a neutral wire when using the star connection method, the two-pole or three-pole type of the thermal relay can be used. However, if the motor is set to use a star connection method with a neutral wire, the thermal relay must use a three-pole type. In addition, generally a two-phase structure thermal relay should be selected for light-load starting, long-term working motors or intermittent long-term working motors; when the current and voltage balance of the motor is poor, the working environment is poor, or there are fewer people to look after, three-phase thermal relay can be used.2.3 Selection of Rated Current of Thermal Relay1) Ensure the normal operation and starting of the motorIn the case of normal starting current and starting time and infrequent starting, it must be ensured that the starting of the motor does not cause the thermal relay to malfunction. When the starting current of the motor is 6 times the rated current, the starting time does not exceed 6s, and rarely starts continuously, the thermal relay can generally be selected according to the rated current of the motor. (In practice, the rated current of the thermal relay can be slightly larger than the rated current of the motor) 2) Consider the object of protection-the characteristics of the motorModels, specifications, and characteristics of motors. The insulation materials of motors are classified into A, E, and B grades. Their allowable temperature rises are different, so their ability to withstand overload is also different, which should be paid attention to when selecting a thermal relay. In addition, the open-type motor is easier to dissipate heat, while the closed-type motor is much more difficult to dissipate heat. With a slight overload, its temperature rise may exceed the limit. Although the selection of the thermal relay is based on the rated current of the motor in principle, the rated current of the thermal relay (or thermal element) that it is equipped with should be appropriately small for the motor with poor overload capacity. In this case, the rated current of the thermal relay (or thermal element) can also be taken as 60% -80% of the rated current of the motor. 3) Consider load factorsIf the nature of the load is not allowed to stop, even if the overload will shorten the life of the motor, the motor should not be allowed to trip unexpectedly, so as not to suffer a huge loss many times higher than the price of the motor. At this time, the rated current of the relay can be selected to a larger value (of course, the selection of the motor under this working condition generally also has a strong overload capacity). In this case, it is best to use the protective measures of the organic combination of thermal relays and other protective appliances, and only consider tripping when a very dangerous overload occurs. In short, this is not a dogmatic formula and should be considered comprehensively. 2.4 Selection of Thermal Element Setting CurrentAccording to model number of the thermal relay and the rated current of the thermal element, the adjustment range of the setting current of the thermal element can be found out. Generally, the setting current of the thermal relay is adjusted to the rated current of the motor; for motors with poor overload capacity, the setting value of the thermal element can be adjusted to 0.6-0.8 times of the rated current of the motor; when the motor starts for a long time, drags the impact load or is not allowed to stop, the setting current of the thermal element can be adjusted to 1.1-1.15 times of the rated current of the motor. 2.5 Reliable and Reasonable Protection Characteristics of The Thermal RelaySpecifically, it should have an inverse time characteristic similar to the allowable overload characteristic of the motor, and it should be below the allowable overload characteristic of the motor, and it should have high accuracy to ensure the reliability of the protective action. 2.6 Other Considerations1) Operating frequency: When the operating frequency of the motor exceeds the operating frequency of the thermal relay, such as the motor's reverse braking, reversible operation, and dense on-off, the thermal relay cannot provide protection. At this time, you can consider using a semiconductor temperature relay for protection. 2) It is not necessary to set overload protection for motors with short working hours and long intervals (such as rocker lifting motors for rocker drilling machines, etc.), and motors that have little possibility of overload despite long-term work(such as exhaust fans, etc.). 3) Thermal relays are generally not suitable for motors with a jog, heavy load starting, continuous forward and reverse rotation, and reverse braking. 4) It should have a certain temperature compensation: due to the change in the temperature of the surrounding medium, under the same overload current, the operation of the thermal relay will cause an error. To eliminate this error, temperature compensation measurements should be set up. 5) In general, the principle that the protected motor should not restart automatically even after the thermal relay is automatically reset after the thermal relay protection action, otherwise, the thermal relay should be set to the manual reset state. This is to prevent the motor from being repeatedly restarted several times to damage the equipment before the fault is eliminated.  For example: Generally, for the control circuit using button control to manually start and stop, the thermal relay can be set to the automatic reset form; for the automatic start circuit using automatic component control, the thermal relay should be set to the manual reset form; Any thermal relay that can be automatically reset should be able to be automatically reset reliably within 5 minutes after operation, while the manual reset one should be reset reliably when the manual reset button is pressed by hand within 2 minutes after the operation. Most products generally have both manual and automatic reset methods and can be adjusted to any method with screws to meet the needs of different occasions. 6) The operating current value should be adjustable to meet the needs in production and use, and reduce the specification-grade, so the thermal relay of a certain specification should be able to be realized by adjusting the cam. 7) Since it takes time for the thermal element to deform due to heat, the thermal relay can only be used as overload protection for the motor, not as short circuit protection. Therefore, when using a thermal relay, a fuse should be installed as short circuit protection. For heavy load, frequent-starting large-capacity important motors, overcurrent relays (time-delay action type) can be used for its overload and short circuit protection. Ⅲ Other Matters Needing Attention3.1 Installation DirectionThe installation direction of the thermal relay is easily overlooked. In the thermal relay, there is a current that generates heat through the heating element, which promotes the action of the bimetal. There are three ways of heat transfer: convection, radiation and conduction. Convection is directional, and heat is transferred from the bottom up. During the placement, if the heating element is under the bimetal, the bimetal will heat up quickly and the action time will be short; if the heating element is next to the bimetal, the bimetal will heat slowly and the action time of the thermal relay will be long.  When the thermal relay is installed with other electrical appliances, it should be installed below the electrical appliances and away from other electrical appliances by more than 50 mm to avoid the influence of other electrical appliances. The installation direction of the thermal relay should be in accordance with the specifications of the product manual to ensure that the thermal relay's operating performance is consistent during use.3.2 Selection of Connecting WiresThe connecting wires at the output end should be selected according to the rated current of the thermal relay. Too thick or too thin will also affect the normal operation of the thermal relay. If the connecting wire is too thin, the heat generated by the connecting wire will be transferred to the bimetallic sheet, and the heat-generating component will dissipate less heat along the wire, which shortens the trip time of the thermal relay.  On the contrary, if the connecting wire is too thick, this will extend the trip time of the thermal relay. For thermal relays with a rated current of 10 A, the cross-sectional area of the connecting wire at the output end is preferably 2.5 mm2 (single-strand copper-core plastic wire), the one of 20 A is preferably 4 mm2 (single-strand copper-core plastic wire), 16 mm2 is suitable for the one of 60 A(multi-strand copper-core rubber flexible wire), and the one of150 A is preferably 35 mm2 (multi-strand copper-core rubber flexible wire).  Because the material and thickness of the wire will affect the heat conduction from the termination of the thermal element to the external heat, if the wire is too thin, the axial thermal conductivity is poor, and the thermal relay may act in advance; if the wire is too thick, the axial heat conduction is fast, and the thermal relay may lag behind. The connecting wire at the output end of the thermal relay is generally a copper core wire. If an aluminum core wire is used, the cross-sectional area of the wire should be increased by 1.8 times, and the end of the wire should be tinned. Reference table for selection of cross-section of connecting wire:Setting current of thermal relay I / ACross-sectional area of connecting wire MM20 < IN ≤81.08 < IN ≤121.512 < IN ≤202.520 < IN ≤254.025 < IN ≤326.032 < IN ≤5010.050 < IN ≤6516.065 < IN ≤8525.085 < IN ≤11535.0115 < IN ≤15050.0150 < IN ≤16070.03.3 Use EnvironmentThis mainly refers to the ambient temperature, which has a greater impact on the speed of the thermal relay. The temperature of the medium surrounding the thermal relay should be the same as the temperature of the medium surrounding the motor, otherwise, the adjusted fit will be destroyed. For example: when the motor is installed in an environment of high temperature and the thermal relay is installed in an environment of lower temperature, the action of the thermal relay will lag (or the action current is large); otherwise, its action will be advanced (or the action current is small). For thermal relays without temperature compensation, they should be used at the place where there is little difference in an ambient temperature between the thermal relay and the motor. For the thermal relay with temperature compensation, it can be used in the place where the environmental temperature of the thermal relay and the motor is different, but the influence caused by the environmental temperature change should be minimized as much as possible. The ambient temperature of the thermal relay and the protected motor should be considered. When the ambient temperature of the thermal relay is lower than the ambient temperature of the protected motor by 15℃, a thermal relay with a larger rated current rating should be used; when the ambient temperature of the thermal relay is lower than the ambient temperature of the protected motor by 15℃, a thermal relay with a smaller rated current rating should be used. In addition, the load of the motor and the adjustment range that the thermal relay may require should also be considered.3.4 Adjustment of Thermal RelayBefore putting it into use, the setting current of the thermal relay must be adjusted to ensure that the set current of the thermal relay matches the rated current of the protected motor. Before the thermal relay is used in the circuit, the specific current of the thermal relay must be adjusted according to the rated current of the motor to meet the requirements of corresponding occasions. For example, for a 10kW, 380V motor with a rated current of 19.9A, a XX20-25 thermal relay can be used. The setting current of the thermal element is 17 ~ 21 ~ 25A. First, set it at 21A according to the general situation. If it is found that it often moves in advance and the temperature rise of the motor is not high, you can change the setting current to 25A and continue to observe; if the motor temperature rises at 21A, and the thermal relay lags, you can change the setting current to 17A and observe to get the best fit. It is used to adjust the rated current when overload protection of the motor is repeatedly operated for a short time. Multiple tests and adjustments in the field can get more reliable protection. The method is: first adjust the rated current of the thermal relay to be slightly smaller than the rated current of the motor. If it is found that it often moves during operation, then gradually increase the rated value of the thermal relay until it meets the operating requirements. There should be motor protection during the special operations. Motors with forward, reverse, and frequent on-off operations should not be protected by thermal relays. The ideal method is to protect it with a temperature relay or thermistor embedded in the winding.  Ⅳ Frequently Asked Questions about Thermal Relay1. What is a thermal relay?A relay that opens or closes contacts with a bending mechanism as a result of the difference in the expansion coefficients of a bimetal, which is heated by the current. ... The thermal relay is combined with a magnetic contactor because it cannot switch the main circuit by itself. The operating point can be changed. 2. How does a thermal relay work?A thermal relay works depending upon the above-mentioned property of metals. The basic working principle of thermal relay is that, when a bimetallic strip is heated up by a heating coil carrying overcurrent of the system, it bends and makes normally open contacts. 3. What is the purpose of thermal overload relay?Thermal overload relays are economic electromechanical protection devices for the main circuit. They offer reliable protection for motors in the event of overload or phase failure. The thermal overload relay can make up a compact starting solution together with contactors. 4. What are the two types of thermal overload relays?Thermal Overload RelaysThermal overloads can be divided into two types: solder melting type, or solder pot, and bimetal strip type. Because thermal overload relays operate on the principle of heat, they are sensitive to ambient (surrounding air) temperature. 5. How do you use a thermal overload relay?Overload relays protect a motor by sensing the current going to the motor. Many of these use small heaters, often bi-metallic elements that bend when warmed by the current to the motor. When the current is too high for too long, heaters open the relay contacts carrying current to the coil of the contactor. 6. How do you test a thermal overload relay?CEP7 Overload Relay test procedures:Measure the normal motor running current (i motor).Turn off the motor and let it cool for about 10 minutes.Calculate the following ratio: i (motor) / i (overload min FLA).Set the overload to its minimum FLA and turn on the motor.Wait for the overload to trip. 7. What is thermal overload relay how it functions?The function of a thermal overload relay, used in motor starter circuits is to prevent the motor from drawing excessive current which is harmful to motor insulation. It is connected either directly to motor lines or indirectly through current transformers. 8. What is the purpose of a thermal overload?Thermal overload relays are protective devices. They are designed to cut power if the motor draws too much current for an extended period of time. To accomplish this, thermal overload relays contain a normally closed (NC) relay. 9. What does a thermal overload relay consist of?Bimetallic thermal overload relays (sometimes referred to as heater elements) are made of two metals, with different coefficients of thermal expansion, that is fastened or bonded together. A winding, wrapped around or placed near the bimetallic strip, carries current. 10. How do I know if my overload relay is bad?Unplug the start relay from the compressor and give it a shake. If you can hear rattling on the inside of the start relay, then the part is bad and will have to be replaced. If it's not rattling and appears to be in good condition, you may have a problem with the actual compressor. 
kynix On 2019-11-30   7322
General electronic semiconductor

Switch Mode Power Supply Circuit Design Tutorial

Many engineers who have not used the switching power supply may have some worry about it, such as the PCB layout, the parameter and type selection of components, and so on. In fact, as long as you understand the basic principle, the use of switching power supply design is very convenient. In today's article, we will introduce you to some basic knowledge of switch-mode power supply, along with some experience sharing when using the switch-mode power supply. SMPS Tutorial: Switch Mode Power Supplies and Power Conversion  Catalog I. What is the Switch Mode Power SupplyII. How to Debug the Switching Power Supply Circuit?III. What Needs to Be Grounded?3.1 Definition of Grounding3.2 Grounding Mode3.3 How is the Signal of the Single Board Grounded?3.4 How Do the Single Board Interface Devices   Grounding?3.5 How to Grounding the Shield Layer?IV. Introduction of Signal Backflow and TranspartitionV. Should Analog Separate from the Digital , and How?FAQ I. What is the Switch Mode Power Supply  A switch-mode power supply usually consists of a controller and an output part. Some controllers integrate MOSFET into the chip, which makes it easier to use and simplify the PCB design, but the flexibility of components is weakened. The switching controller is actually a closed-loop feedback control system, so there is a sampling circuit of output-voltage feedback and a feedback-loop control circuit. Therefore, this part of the design is to ensure an accurate sampling circuit and to control the feedback depth, because if the feedback loop response is too slow, it will have a great impact on the transient response-ability. The output parts include output capacitance, output inductor, MOSFET, and so on. The selection of these devices is basically to balance the performance need and cost. For example, the high switching frequency can use small inductance (which means small package and low cost), but a high switching frequency will increase interference and the switching loss of MOSFET, result in reducing efficiency and increasing cost. Lower switching frequency has the opposite effect. The selection of Rds_on parameters of MOSFET and the ESR for output capacitance is also very important. ESR is small can reduce output ripple, but the cost of the capacitor will increase. And It is important to note that switching power controllers can not be well driven with too much MOSFET. In general, suppliers of switching power supply controllers will provide specific formulas and usage options for engineers. Figure. 1 Switch Mode Power Supply Circuit   II. How to Debug the Switching Power Supply Circuit? (1)The output of the power supply circuit is installed to the board through the low resistance and high power resistor, so that the power circuit can be debugged first before welding resistance, avoiding the influence of the latter circuit.  (2)The switching controller is a closed-loop system. If the output deterioration beyond the range that the closed-loop can control, the switching power supply will work improperly. This situation requires careful examination of feedback and sampling circuits. Especially, if the output capacitance with a large ESR, lots of ripple of power supply will be produced, which will also affect the operation of switching power supply.  III. What Needs to Be Grounded? At the very start, the introduction of grounding technology is a protective measure to prevent lightning strikes on electric power or electronic equipment. The purpose is to introduce lightning current through the lightning rod to the earth to protect buildings. And meanwhile, grounding is also an effective way to protect personal safety.  When the phase line touches the shell of the equipment causing by some reason (such as poor insulation of the wire, line aging, etc.), there will be a dangerous voltage in the shell of the equipment. Having grounding, the resulting fault current will flow to the earth, thus it plays a protective role.  For example, in communication systems, the interconnection of signals between a large number of devices requires each device to have a point as a reference, and with the complication of electronic equipment, the signal frequency is becoming higher and higher, therefore, grounding design as special attention paid to the electromagnetic compatibility problems such as mutual interference between signals.  In addition, improper grounding will seriously affect the reliability and stability of system operation. Recently, the concept of "grounding" has also been introduced into high-speed signal backflow technology.  3.1  Definition of GroundingIn the modern concept of grounding, for line engineers, the term usually means "reference point for line voltage"; for system designers, it is often a cabinet or frame; for electrical engineers, it is a green and safe ground line or a wire connected to the earth. A more general definition is that "grounding is the low impedance channel which the current returns its source." Noting that the points are "low impedance" and "channel".  3.2  Grounding ModeThere are many ways of grounding: single-point grounding, multi-point grounding, and mixed type of grounding. Single-point grounding is divided into a series of single-point grounding and parallel single-point grounding. In general, single-point grounding is used in simple circuits, and low frequency (f10MHz) circuits use multipoint grounding or multilayer (complete a ground plane layer).  3.3   How is the Signal of the Single Board Grounded?For the general device, the near ground is the best. After adopting the multilayer design with a complete ground plane, the grounding of the general signal is very easy. The basic principle is to ensure the continuity of the line, reduce the number of holes, approach the ground plane or the power plane, etc. 3.4  How Do the Single Board Interface Devices  Grounding?Some veneers will have external input-output interfaces, such as serial port connectors, RJ45 connectors, etc. If their grounding is not well designed, it will also affect normal operation, such as error codes, packet loss, etc. And it will become an external source of electromagnetic interference sending the noise out. In general, a single interface grounding will be made, and the signal is connected by a thin wire connection, string 0 ohms, or small resistance. Thin lines can be used to block signal ground noise. At the same time, the interface and the interface power filter should also be considered seriously.  3.5  How to Grounding the Shield Layer? The shielding layer of cables is connected to the interface grounding instead of the signal grounding, because there are various noises on the signal grounding. If the shield layer is connected to the signal ground, the noise voltage will drive the common-mode current to interfere outward along the shield layer. Therefore, the poorly designed cable is generally the maximum noise output source of electromagnetic interference. Of course, the interface ground should keep clean. IV. Introduction of Signal Backflow and TranspartitionFor an electronic signal, it needs to find a way with the lowest impedance to return current to the ground, so how to deal with the signal backflow becomes very important. First, according to the formula, we can know that the radiation intensity is proportional to the area of the loop. Specifically, the longer the path the return is, the bigger the ring is formed, and the greater the external radiation interference is, thus the power-circuit flow back and signal loop area should as small as possible when design PCB. Second, for a high-speed signal, providing a good signal backflow can guarantee its signal quality. Because the characteristic impedance of the transmission line on the PCB is generally calculated by reference to the ground (or power layer), if there is a continuous ground plane near the high-speed line, the impedance of this line can be kept continuous, and if there is no ground reference near the section line, the impedance will change and the signal will be affected as well. Therefore, the high-speed lines should be distributed to the layer near the ground plane, or they should be walked in parallel next to each other, to shield interference and provide backflow nearly.  Third, do not divide wires when having power supply in wiring way, this is because the signal backflow path across different power layers will be longer, and be vulnerable to interference. For low-speed signals, it is not strictly required that, because the resulting interference signal can not be concerned about. But for high-speed signals should be checked carefully, do not cross as far as possible, you can adjust the power part of the wire. (this is for multiple power supplies on multilayer boards).  V. Should Analog Separate from the Digital , and How? Whether analog signal or digital signal should return to the ground. Because the digital signal changes quickly and the noise caused by the digital signal will be very large, if analog and digital mixing, the noise will affect the analog signal.  In general, the grounding of analog and digital processing must be separated, then connected by a thin line, or a single point. The general idea is to try to block the noise from the digital ground to the analog ground. But it is not a very strict requirement that analog and digital ground must be separated, if the analog section near the digital ground is still very clean, they can be combined. FAQ 1. What are the 3 types of power supply?There are three subsets of regulated power supplies: linear, switched, and battery-based. Of the three basic regulated power supply designs, linear is the least complicated system, but switched and battery power have their advantages. 2. What is meant by switch mode power supply?A switch mode power supply is a power converter that utilises switching devices such as MOSFETs that continuously turn on and off at high frequency; and energy storage devices such as the capacitors and inductors to supply power during the non-conduction state of the switching device. 3.What are the advantages and disadvantages of switch mode power supply?Advantages & disadvantages of switch mode power supply (SMPS)a. The switch mode power supply has a smaller in size.b. The SMPS has light weight.c. It has a better power efficiency typically 60 to 70 percent.d. It has a strong anti interference.e. SMPS has wide output range.f. Low heat generation in SMPS. 4. What is a DC switching power supply?A Switching DC power supply (also known as switch mode power supply) regulates the output voltage through a process called pulse width modulation (PWM). The PWM process generates some high frequency noise, but enables the switching power supplies to be built with very high power efficiency and small form factor. 5. What is the difference between a switching power supply and a linear power supply?Linear power supplies deliver DC by passing the primary AC voltage through a transformer and then filtering it to remove the AC component. Switching power supplies feature higher efficiencies, lighter weight, longer hold up times, and the ability to handle wider input voltage ranges. 6. Do I need a switching power supply?The switching power supply implies higher efficiency due to the high switching frequency, enabling it to use a smaller, less-costly high-frequency transformer as well as lighter, less-costly filter components. Switching power supplies contain more overall components, therefore are usually more expensive. 7. Is a switching power supply regulated?A switch mode power supply regulates an output voltage with pulse width modulation (PWM). This process creates high-frequency noise but it provides a high-efficiency rating in a small form factor. ... The low DC voltage is finally converted into a steady DC output with another set of diodes, capacitors, and inductors. 8. How do I know if my power supply is regulated?You can generally stick one probe into the middle of the connector, and hold the other against the outside. With a few exceptions, the middle is positive, so use the red lead there, and use the black lead on the outside shell. Regulated supplies, without any load, should measure very close to the target voltage of 12v. 9. Can I use a switching power supply to drive a DC motor?A simple unregulated analog power supply may be easier and be able to supply the large starting under load current more that the switching one. DC motors are not too fussy about the supply, and will usually run quite well on unfiltered DC. 10. Are switch mode power supplies any good?Switch mode power supplies, SMPS provide improved efficiency & space saving over traditional linear supplies, but care has to be taken to ensure noise on the output is low. Switch mode power supplies are widely used because of the advantages they offer in terms of size, weight, cost, efficiency and overall performance. You May Also LikeSwitching Power Supply Guide: Protection CircuitSwitching Power Supply Tutorial: 4V~16VSwitched Mode Power Supply Tutorial: Principles & Functions of SMPS Circuits
kynix On 2018-11-05   2277
General electronic semiconductor

Switched Mode Power Supply Tutorial: Principles & Functions of SMPS Circuits

Warm hints: The word in this article is about 3000 words and reading time is about 12 minutes.     This article would introduce you different kinds of power supply circuits.   Catalog   I. Circuit Arrangement of Switching Power Supply II. The Principle of the Input Circuit and the Common Circuits 2.1 Principle of AC Input Rectifier Filter Circuit 2.1.1 Lightning Protection Circuit 2.1.2 Input Filter Circuit 2.1.3 Rectifier Filter Circuit 2.2 Principle of DC Input Filter Circuit 2.2.1 Input Filter Circuit 2.2.2 The Anti-surge Circuit III. Power Conversion Circuits 3.1 The Working Principle of MOS Tube 3.2  Common Schematic Diagram 3.3 Working Principle 3.4 Push-pull Power Conversion Circuit 3.5 Power Conversion Circuit with Transformer Driver IV. Output Rectifier Filter Circuit 4.1 Forward Rectifier Circuit 4.2 Flyback Fectifier Circuit 4.3 Synchronous Rectifier Circuit V. Principles of Steady-voltage Loop 5.1 Schematic Diagram of Feedback Circuit 5.2 Working Principles VI. Short Circuit Protection Circuits 6.1 Current-limiting Circuit 6.2 Short Circuit Protection for Low-power Circuit 6.3 Short Circuit Protection for Medium-power Circuit 6.4  Common Current-limiting, Short-circuit Protection Circuit 6.5 Current Transformer Sampling Current Protection Circuit VII. Output Current Limiting Protection VIII. Output Overvoltage Protection Circuits 8.1 SCR Trigger Protection Circuit 8.2 Optocoupler Protection Circuit 8.3 Output Voltage Limiting Protection Circuit 8.4 Output Overvoltage Lockout Circuit IX. Power Factor Correction Circuit (PFC) 9.1 Schematic Diagram of PFC Circuit 9.2 The Working Principles X. Input Under-voltage and Overvoltage Protection 10.1 Schematic Diagram 10.2 The Working Principles FAQ       I. Circuit Arrangement of Switching Power Supply   The main circuit of the switch-mode power supply is composed of an input EMI filter, rectifier filter circuit, power conversion circuit, and PWM controller circuit, output rectifier filter circuit. The auxiliary circuits include the input & output Undervoltage protection circuit, the output overcurrent protection circuit, the output short circuit protection circuit, and so on.   The block diagram of switching power supply circuit arrangement is as follows:   FIG.1 Block diagram of switching power supply circuit arrangement   II. The Principle of the Input Circuit and the Common Circuits   2.1 Principle of AC Input Rectifier Filter Circuit 2.1.1    Lightning Protection Circuit When there is a lightning strike, the circuit composed of MOV1, MOV2, MOV3, F1, F2, F3, and FDG1 is used to provide protection against the resulting high voltage introduced into the power supply through the electrical grid.   When the voltage applied to the two ends of the piezoresistor exceeds its operating voltage, the resistance value will decrease, making the high voltage energy be consumed on the piezoresistor; if the current is too large, the F1, F2, and F3 will burn out to protect the following circuits. 2.1.2     Input Filter Circuit The double Pi filter network composed of C1, L1, C2 and C3 is mainly used to suppress the electromagnetic noise and clutter signal of the input power supply to prevent its interference to the power supply, and also to prevent the interference of the high-frequency clutters generated by the power supply itself to the electrical grid. The C5 will start to be charged when the power is turned on, producing a large instantaneous current, which is called surge current, but with an RT1 (thermistor) it can be effectively prevented. Because the instantaneous energy is all consumed on the RT1, after a certain time the resistance of RT1 will decrease as the temperature rises (RT1 is a negative temperature coefficient device) and the energy consumed by RT1 will be very small at this time, to make sure the following circuits work normally.     2.1.3   Rectifier Filter Circuit After the AC voltage is rectified by BRG1 and filtered by C5, a purer DC voltage can be obtained. If the C5 capacity becomes smaller, the output AC ripples increase with it.     2.2 Principle of DC Input Filter Circuit FIG.3 The schematic of rectifier circuit   2.2.1   Input Filter Circuit The double Pi filter network composed of C1, L1and C2 is mainly used to suppress the electromagnetic noise and clutter signal of the input power supply to prevent its interference to the power supply, and also to prevent the interference of the high-frequency clutters generated by the power supply itself to the electrical grid. C3 and C4 are Safety Capacitors and the L2, L3 are Differential Mode Inductors.   2.2.2   The Anti-surge Circuit This anti-surge circuit is composed of R1, R2, R3, Z1, C6, Q1, Z2,  R4, R5, Q2, RT1 and C7. At the instant of switch-on, Q2 does not conduct due to the presence of C6, and the current forms a loop through the RT1. Q2 turns on when the voltage on C6 is charged to Z1's steady voltage value. If C8 leaks or the following circuits are short-circuited, the voltage drop generated by the instantaneous current at the instant of switch-on on RT1 causes the Q1 conducted, so that Q2 does not have a gate voltage and does not conduct, making the RT1 burnt out in a very short time to protect the following circuits.   III. Power Conversion Circuits   3.1   The Working Principle of MOS Tube At present, the most widely used insulated gate FET is MOSFET, which uses the electroacoustic effect that occurs on the semiconductor surface to work, making it also known as surface field effect transistor. Because its gate is in a nonconducting state, the input resistance can be greatly increased up to 105 ohms. The MOSFET uses the gate-source voltage to change the amount of charge induced on the semiconductor surface to control the drain current.   3.2   Common Schematic Diagram FIG.4 Schematic of power conversion circuit    3.3  Working Principle The buffer composed of R4, C3, R5, R6, C4, D1, and D2 are connected in parallel with the MOS transistor switches, so that the voltage stress of the switch transistor and EMI are reduced, without secondary breakdown occurring. When the switch Q1 is turned off, the primary coil of the transformer is prone to generate peak voltages and spike currents. These components are combined to absorb the peak voltage and current well. The peak current signal measured from R3 participates in the duty cycle control of the current operating cycle and is therefore the current limit of the current operating cycle. When the voltage on R5 reaches 1V, the UC3842 stops working and switch Q1 turns off immediately.   The junction capacitances CGS and CGD in R1 and Q1 together form an RC network. The charge and discharge of the capacitor directly affects the switching speed of the switch. If R1 is too small, it will cause oscillation and electromagnetic interference will be great. If R1 is too large, the switching speed of the switching tube will be reduced. Z1 usually limits the GS voltage of the MOS transistor to less than 18V, thus protecting the MOS transistor.   The gate-controlled voltage of Q1 is a saw wave. The larger the duty cycle is, the longer the Q1 conduction time is, the more energy the transformer stores. When Q1 is turned off, the transformer releases energy through D1, D2, R5, R4, and C3 and at the same time, it also achieves the goal of resetting the magnetic field, which prepares the transformer for the next storage and transfer of energy. According to the output voltage and current, the IC adjusts the duty cycle of 6-pin sawtooth wave, thus stabilizing the output current and voltage of the complete machine.   C4 and R6 are voltage surge absorption loops.   3.4  Push-pull Power Conversion Circuit Fig.5 Schematic diagram of push-pull power conversion circuit Q1 and Q2 will be turned on in turn.   3.5  Power Conversion Circuit with Transformer Driver FIG.6 Schematic diagram of power conversion circuit with transformer driver T2 is the transformer driver, T1 is the switch-mode transformer, TR1 is the current loop .   IV. Output Rectifier Filter Circuit   4.1   Forward Rectifier Circuit FIG.7 Schematic diagram of forward rectifier circuit T1 is a switch-mode transformer, its primary and secondary sides are in a same phase. D1 is a rectifier diode, D2 is a flyback diode and R1, C1, R2 and C2 form a despiker circuit. L1 is a freewheeling inductor and C4, L2, and C5 form a π filter.   4.2  Flyback Fectifier Circuit FIG.8 Schematic diagram of flyback fectifier circuit T1 is a switch-mode transformer, and the primary and secondary sides are opposite. D1 is a rectifier diode, and R1 and C1 form a despiker circuit. L1 is a a freewheeling inductor, R2 is adummy load and C4, L2 and C5 form a π type filter.   4.3   Synchronous Rectifier Circuit FIG.9 Schematic diagram of synchronous rectifier circuit Working principle: When the upper end of the secondary winding of transformer is positive, the current through C2, R5, R6 and R7 makes Q2 turned on and form a loop. Q2 is the rectifier and the Q1 gate is turned off due tothe reverse bias. When the lower end of second wingding is positive, the current through C3, N4 and R2 makes Q1 conducted as a freewheeling diode. The Q2 gate is turned off due to the reverse bias. L2 is a freewheeling inductor, C6, L1 and C7 form a π filter and R1, C1, R9 and C4 form a despiker circuit.   V.  Principles of Steady-voltage Loop   5.1  Schematic Diagram of Feedback Circuit FIG.10 Schematic diagram of feedback circuit 5.2  Working Principles When the output U0 is increased, the voltage of pin 3 of U1 chip is increased either after dividing voltage with these sampling resistors R7, R8, R10 and VR1, until exceeding the reference voltage of pin 2 of U1 chip, it begins to output a high level, turning the Q1 and photoelectric triode on, and lighting the optocoupler OT1 and LED. Accordingly, the potential of pin 1 of UC3842 becomes lower and therefore decreases the duty cycle of pin 6 of U1 chip and U0.    On the contrary, when the output U0 is decreased, the voltage of pin 3 of U1 chip is decreased either until it exceeds the reference voltage of pin 2 of U1 chip, it begins to output a low level, Q1 and photoelectric triode are not conducting, and optocoupler OT1 and LED do not shine. Accordingly, the potential of pin 1 of UC3842 becomes higher and therefore increases the duty cycle of pin 6 of U1 chip and U0. Repeatedly, so that the output voltage remains stable. Regulating VR1 can change the output voltage.   Feedback loop is an important circuit that affects the stability of switching power supply. If the feedback resistors and capacitors are wrong, missed or false soldered, self-excited oscillations will occur, resulting in fault phenomena, such as abnormal waveforms, oscillations within empty or full load condition and unstable output voltage.   VI. Short Circuit Protection Circuits   6.1  Current-limiting Circuit In the case of short circuit at the output end, PWM control circuit can limit the output current within a safe range. There are many ways to  realize the current limiting. When the current limiting circuit does not work in short circuit, all we can do is to add additional circuits.   6.2  Short Circuit Protection for Low-power Circuit FIG.11 Schematic diagram of low-power short-circuit protection circuit When the output circuit is shorted, the output voltage disappears, the optocoupler OT1 does not turn on, the voltage of pin 1 of UC3842 rises to about 5V, and the partial voltages of R1 and R2 exceed the TL431 reference, making it conductive, the VCC potential of pin 7 of UC3842 is pulled down, and the IC stops operating. After UC3842 stopped working, the potential of pin 1 disappeared, TL431 did not conduct, and the potential of UC38427 increased, making UC3842 restart, and go round and begin again, until the short-circuit phenomenon disappears, then the circuit automatically returns to normal operation.   6.3  Short Circuit Protection for Medium-power Circuit FIG.12 Schematic diagram of medium-power short-circuit protection circuit When the output is short-circuited, the voltage of pin of UC3842 rises. When the potential of pin 3 of U1 chip is higher than that of pin 2, the comparator inverts the output high level of pin 1 to charge C1. When the voltage across C1 exceeds the pin 5 reference voltage, the pin 7 of U1 chip outputs low level. The voltage of pin 1 of UC3842 begins to be lower than 1V and UC3842 stops working, making the output voltage be zero, and go round and begin again, until the short-circuit phenomenon disappears, and the circuit begins to work normally. R2 and C1 are charge and discharge time constants respectively, and the short circuit protection will not work if the resistance is not correct.   6.4  Common Current-limiting, Short-circuit Protection Circuit FIG.13 Schematic diagram of protection circuit 1 When the output circuit is short-circuited or overcurrent, the primary current of the transformer increases, the voltage drop across R3 increases, the voltage at pin 3 increases, and the duty cycle of pin 6 of UC3842 increases. When the voltage at pin 3 exceeds 1V, the UC3842 turns off and without output.   6.5  Current Transformer Sampling Current Protection Circuit The current transformer sampling current protection circuit which has low power consumption but high cost, and the circuit is often complicated. FIG.14 Schematic diagram of protection circuit 2 The larger the output current is (the extreme case refers to short circuit), the higher the voltage sensed by the TR1 secondary coil. When the voltage of pin 3 of UC3842 exceeds 1 volt, the UC3842 stops working. Go round and begin again, until the short-circuit or overload disappears, the circuit recovers itself.   VII. Output Current Limiting Protection FIG.15 Schematic diagram of protection circuit 3 The above is a common output current limiting protection circuit, and its working principle is as follows:   When the output current is too high, the voltage across the RS (manganese copper wire) rises, the voltage of pin 3 of the U1 chip is higher than the reference voltage of pin 2. Pin 1 of the U1 chip outputs a high voltage, which makes Q1 turned on, and the optoelectronic effect occurs on the optocoupler, the voltage of pin 1 of UC3842 is reduced, together with the output voltage, to achieve the goal of overload protection or current limiting.     VIII. Output Overvoltage Protection Circuits   The role of the output overvoltage protection circuit is to limit the output voltage to a safe value when the output voltage exceeds the design value.    When an internal voltage regulator loop of a switching power supply fails or an overvoltage occurs due to a user's improper operation, an overvoltage protection circuit is used to protect against damage to downstream electrical equipment.   The most commonly used overvoltage protection circuits are as follows:   8.1  SCR Trigger Protection Circuit FIG.16 Schematic diagram of protection circuit 4 As shown above, when the output of Uo1 rises, the Zener diode (Z3) breaks down and it is pulled into conduction, letting the control terminal of the Silicon Controlled Rectifier reach the trigger voltage, so the SCR turns on and the Uo2 is shorted to ground. Then the overcurrent or short circuit protection circuit will work and stop the operation of the entire power supply circuit. When the overvoltage condition on the output terminals is eliminated, the trigger voltage of the control terminal of the thyristor is discharged to the ground through R, and the thyristor returns to the off state.   8.2  Optocoupler Protection Circuit FIG.17 Schematic diagram of protection circuit 5A FIG.18 Schematic diagram of protection circuit 5B As shown in the above figure, when an phenomenon of overvoltage occurs in the Uo, the Zener breaks down and conducts current through the optocoupler (OT2) and R6 to the ground, lightening the light-emitting diode of the photocoupler, which causes the phototransistor of the photocoupler to conduct. The base of Q1 is turned on and the voltage of pin 3 of UC3842 is reduced, turning off the IC and the entire power supply while Uo is zero, and go round and begin again.   8.3  Output Voltage Limiting Protection Circuit FIG.19 Schematic diagram of protection circuit 6 The output voltage limiting protection circuit is shown in the diagram. When the output voltage rises, zener and optocoupler are on, and the base of Q1 turns on either due to a driving voltage according. The voltage of pin 3 of UC3842 rises and the output drops. When the zener is not conducting, the voltage of pin 3 of UC3842 drops and the output voltage rises. As time goes by, the output voltage will be stable within a range (depending on the zener's value).   8.4  Output Overvoltage Lockout Circuit FIG.20 Output overvoltage lockout circuit A FIG.21 Output overvoltage lockout circuit B The working principle is shown in Figure A is that when the output voltage Uo rises, the Zener and optocoupler turn on, and then go with the base of Q2, because of which the base of Q1 is on due to the drop of voltage.   Q2 is on all the time after the voltage of Vcc is through R1, Q1, and R2, making the pin 3 of UC3842 always be conducted with high level and therefore stop working.   In Figure B, the voltage of pin 3 of the U1 chip raises due to big rises of Uo, and pin 1 outputs a high level. Because of the presences of D1 and R1, the pin 1 of U1 chip is always on and outputs a high level, so it is always low and then it stops working. Is it positive feedback?     IX. Power Factor Correction Circuit (PFC)   9.1 Schematic Diagram of PFC Circuit FIG.22 Schematic diagram of PFC circuit 9.2  The Working Principles The input voltage is rectified by an EMI filter composed of L1, L2, L3, and so on and a BRG1, one part of which is then fed into the PFC inductor and another part of which is fed into the PFC controller as the sampling of the input voltage to adjust the duty cycle of the control signal before divided by R1 and R2, that is to change them on and off time of Q1 and to stabilize the output voltage of PFC.   L4 is a PFC inductor that stores energy when Q1 is on and releases energy when Q1 is switched off. D1 is the start diode. D2 is the PFC rectifier diode, and C6, C7 are filtered. One part of the PFC voltage is sent to the downstream circuit, and another part of it is fed into the PFC controller as the sampling of the output voltage before divided by R3 and R4, to adjust the duty cycle of the control signal and to stabilize the output voltage of PFC.     X. Input Under-voltage and Overvoltage Protection   10.1  Schematic Diagram FIG.23 Schematic diagram of input undervoltage and overvoltage protection circuit   10.2  The Working Principles The input under-voltage and overvoltage protection principles of the switching power supply of AC input and DC input are almost the same. The sampling voltages of the protection circuits all come from the same input filtered voltage.   The sampling voltage is divided into two ways, one way is fed into pin 3 of the comparator after divided by R1, R2, R3, and R4. If the sampling voltage is higher than the reference voltage of pin 2, then pin 1 of the comparator will output a high level to control the main controller and make the main controller turned off, so there is no power output. The other way is fed into pin 6 of the comparator before it is divided by R7, R8, R9, and R10.   If the sampling voltage is lower than the reference voltage of pin 5, then pin 7 of the comparator will output a high level to control the main controller and make it turned off, so there is no power output.   How To Make a Switching Power Supply     FAQ   1. What are the 3 types of power supply? There are three subsets of regulated power supplies: linear, switched, and battery-based. Of the three basic regulated power supply designs, linear is the least complicated system, but switched and battery power have their advantages.   2. What is meant by switch mode power supply? A switch mode power supply is a power converter that utilises switching devices such as MOSFETs that continuously turn on and off at high frequency; and energy storage devices such as the capacitors and inductors to supply power during the non-conduction state of the switching device.   3.What are the advantages and disadvantages of switch mode power supply? Advantages & disadvantages of switch mode power supply (SMPS) a. The switch mode power supply has a smaller in size. b. The SMPS has light weight. c. It has a better power efficiency typically 60 to 70 percent. d. It has a strong anti interference. e. SMPS has wide output range. f. Low heat generation in SMPS.   4. What is a DC switching power supply? A Switching DC power supply (also known as switch mode power supply) regulates the output voltage through a process called pulse width modulation (PWM). The PWM process generates some high frequency noise, but enables the switching power supplies to be built with very high power efficiency and small form factor.   5. What is the difference between a switching power supply and a linear power supply? Linear power supplies deliver DC by passing the primary AC voltage through a transformer and then filtering it to remove the AC component. Switching power supplies feature higher efficiencies, lighter weight, longer hold up times, and the ability to handle wider input voltage ranges.   6. Do I need a switching power supply? The switching power supply implies higher efficiency due to the high switching frequency, enabling it to use a smaller, less-costly high-frequency transformer as well as lighter, less-costly filter components. Switching power supplies contain more overall components, therefore are usually more expensive.   7. Is a switching power supply regulated? A switch mode power supply regulates an output voltage with pulse width modulation (PWM). This process creates high-frequency noise but it provides a high-efficiency rating in a small form factor. ... The low DC voltage is finally converted into a steady DC output with another set of diodes, capacitors, and inductors.   8. How do I know if my power supply is regulated? You can generally stick one probe into the middle of the connector, and hold the other against the outside. With a few exceptions, the middle is positive, so use the red lead there, and use the black lead on the outside shell. Regulated supplies, without any load, should measure very close to the target voltage of 12v.   9. Can I use a switching power supply to drive a DC motor?   A simple unregulated analog power supply may be easier and be able to supply the large starting under load current more that the switching one. DC motors are not too fussy about the supply, and will usually run quite well on unfiltered DC.   10. Are switch mode power supplies any good? Switch mode power supplies, SMPS provide improved efficiency & space saving over traditional linear supplies, but care has to be taken to ensure noise on the output is low. Switch mode power supplies are widely used because of the advantages they offer in terms of size, weight, cost, efficiency and overall performance.   You May Also Like: Transformers Basics: Construction, Types, Materials and Design Modeling and Control of Full Bridge Push-Pull Bi-Directional DC/DC Converter Review and Application of Electronic skin How to Drive Thermostat by Using Solid State Relay
kynix On 2018-06-13   2446
General electronic semiconductor

Modeling and Control of Full Bridge Push-Pull Bi-Directional DC/DC Converter

Warm hints: The word in this article is about 3000 words and  reading time is about 10 minutes.SummaryFull bridge push-pull bi-directional DC/DC converters are mostly modeled by state space averaging method with the complex modeling process. Taking the isolated form push-pull bi-directional DC/DC converter as the research object, this article adopted the pulse-width modulation switch model method to obtain the equivalent circuit model of this converter. Based on this model, this article constructed a closedloop control system of the converter under different working modes, carried out the design and verification of voltage control loop and realized the constant voltage charge-discharge control strategy. The experimental and simulation results verify the correctness of the conclusion. CoreFull bridge push-pullPurposeTo obtain the equivalent circuit model of the converterEnglish nameBidirectional DC/DC convertersCategoryElectromechanical deviceFunctionConverting a source of direct current (DC) from one voltage level to anotherFeatureAdopting the pulse-width modulation switch model method CatalogsCatalogs1. Foreword2.2 Modeling of bi-directional DC/DC converter4 Epilogue2. Principle and design2.3 Voltage Closed-loop Control and Simulation 2.1 The working principle of circuit3 Experimental result   Introduction1. ForewordBidirectional DC/DC converters have been widely applied in many fields such as electric vehicles and battery energy storage systems. Bidirectional DC/DC converters have different circuit topologies according to their applications.I have seen some examples of using Buck/Boost converter to realize the bi-directional flow of electric energy. Because there is no transformer in the converter, so the electrical isolation of the high and low voltage side can not be realized, and only a small voltage range has been allowed. In order to solve this problem, it is proposed to use isolation transformer in bidirectional full-bridge DC/DC transform circuit, but the converter uses too many switching devices and therefore causes too many power losses. The isolated full bridge push-pull bi-directional DC/DC converter has been widely used due to the advantages of both types of converters of itself.At present, the state space averaging method is used to deduce the small signal model of bidirectional DC/DC converter, which needs a large amount of mathematical derivations and calculations. In order to simplify the modeling process, the full-bridge push-pull bi-directional DC/DC converter is modeled by using PWM-switch modeling method. The transfer function between output voltage and duty cycle of the converter is obtained in two modes: boost mode and buck mode. In addition , the voltage closed loop control system is constructed based on the derived circuit model, and the voltage loop is designed and corrected by the compensation network , realizing the constant voltage control of the full-bridge push-pull bidirectional DC/DC converter.First step in developing feedback control for a dc-dc converter is modeling. Here, we model the buck converter in terms of average behavior. Detail2. Principle and design2.1 The working principle of circuitFigure 1 shows the topology of the main circuit of full bridge push-pull bi-directional DC/DC converter. ^The power switch tubes S1~S4  are arranged in the form of a full-bridge circuit;^the power switch tubes S5~S6 are arranged in the form of a push-pull circuit;^CHV is a parallel capacitor with HVDC busbar;^CLV is a parallel capacitor with LVDC busbar;^L is a  low-voltage-side energy storage filter inductor;^HV is high-voltage-side DC bus;^LV is a low-voltage-side DC bus.Figure 1 Main circuit of bidirectional DC/DC converterFigure 2 and 3 respectively give the schematic diagrams of the PWM driving waveform of the power switch tube working in boost and buck mode, and the schematic diagram of the voltage waveform of the primary and secondary sides of the transformer. The u12 shown in the diagram is the transformer primary-side voltage and the u34 is the transformer sub-side voltage.Figure 2 Waveforms of the  power switch tube working in boost modeFigure 3 Waveforms of the  power switch tube working in buck mode2.2 Modeling of bidirectional DC/DC converterThe basic idea of PWM-switch modeling method: the nonlinear part will be linearized by taking an average value of the voltage and the current of it in one switching period when it is a stable circuit, and therefore the nonlinear circuit will turn into a linear circuit. The push-pull bidirectional DC/DC converter working in the buck mode can be equivalent to the circuit shown in Fig. 4 (the circuit in the dashed box is meant to indicate the nonlinear circuit), which turns on during [0, DTs] and turns off during [DTs, Ts], where Ts is the switching cycle and D is the duty ratio of the full bridge push-pull bi-directional DC/DC converter turn on. In the mathematical expressions presented in this article, all the uppercase variables represent the steady-state values, and all the lowercase variables represent the instantaneous values.Figure 4 Conducting circuit in buck mode operationIn the equivalent circuit shown in figure 4, the voltage and current are averaged during a PWM switching cycle, among which idc is primary instantaneous current and iL is secondary instantaneous current of transformer; iC is instantaneous current of electric capacity CLV; ucp is the instantaneous voltage between nodes c and p; uap is the instantaneous voltage between nodes a and p; n is the transformation ratio.Assuming that the duty cycle is d=D, now add an AC small signal to its value attachment (where small angle brackets denote AC small signals and the other variables following are the same), the complete instantaneous value expression for duty cycle is as shown in formula 3:Then substituting equation 3 into the original yields equation 1 and 2, so we have:Neglecting the product term of AC small signal, and equation 4 and 5 of  AC small signal can be simplified as equation 6 and 7:The mathematical relations of voltage and current working in steady state (following yields equation 8 and 9) derived from original yields equation 1 and 2, along with equation 6 and 7 can be used to obtain equivalent circuit model of bidirectional DC/DC converter in Buck mode (see the two-port circuit shown in the dashed box of figure 5). The model is linear since the constraint equations describing the two-port circuit are all linear equations. It can be learned from the above modeling process that the linear model of the full bridge push-pull bidirectional DC/DC converter can be easily established by using the switching model modeling method, which has the advantages of less calculation and simple derivation. It can be learned from the above modeling process that the linear model of the full bridge push-pull bidirectional DC/DC converter can be easily established by using the PWM-switch modeling method, which has the advantages of less calculation and simple derivation.The equation 10 gives transfer function between the output voltage and duty cycle of low voltage side bus according to laws of KCL and KVL.Figure 5 gives the equivalent circuit of bidirectional DC/DC in Buck mode obtained from equation 10, among which UHV is the operating voltage of high voltage side bus in steady state, uLV is the instantaneous voltage of low voltage side bus, n is the transformer ratio, R is the load resistance of low-voltage-side DC bus, Uap/D can be regarded as controlled voltage source, and IL/n can be regarded as controlled current source.Figure 5 Small signal equivalent circuit in Buck mode operationThe transfer function between duty cycle and output voltage in Boost mode can be obtained by using the same analysis method as Buck mode, which has shown in equation 11. R1 is the load of high voltage side bus.2.3 Voltage Closed-loop Control and SimulationFigure 6 gives the block diagram of the closed loop control system of small signal circuit model of the full bridge push-pull bidirectional DC/DC converter in two different operating modes. Charge and discharge at constant voltage in two modes can be realized by voltage closed-loop control.What we can see from figure 6:Uref is the given voltage of high-voltage-side and low-voltage-side DC bus; Hv(s) is the transfer function of sampling; Gm(s) is the transfer function of PWM; Gcv(s) is the transfer function of PI of voltage control loop; Gvd(s) is the transfer function of voltage versus duty cycle.Figure 6 Block diagram of voltage closed loop controlTo theoretically verify the correctness of mathematical model establishment and the feasibility of voltage control strategy, we use the PSIM 9.0 software tool for simulation and analysis in this article. Figures 7 and 8 have respectively shown the simulated waveforms in different operating modes. In Buck mode operation, the voltage of low voltage bus can be stabilized at 12V, so the constant voltage charging has been realized; and in Boost mode operation, the voltage of high voltage bus can be stabilized at 400V, so the constant voltage discharge has been realized, which theoretically verifies the correctness of mathematical model establishment and the feasibility of voltage control strategy. u12 and u34 are the voltages of the primary and secondary sides of the transformer respectively, uHV and uLV are voltages of high-voltage side and low-voltage side bus.Figure 7 Simulated voltage waveform in boost mode operationFigure 8 Simulated voltage waveform in buck mode operation Analysis3 Experimental resultIn order to verify the correctness of the small-signal circuit model and the feasibility of voltage feedback control, we built an experimental platform of full-bridge push-pull bi-directional DC/DC converter using TMS320F28035 as the core control chip.Table 1 gives the main circuit parameters of the bidirectional DC/DC converter based on the full bridge push-pull circuit structure.Table 1 Basic circuit parameters of converterFigure 9 gives the output voltage waveform of secondary voltage and low-voltage-side DC bus of transformer in buck mode operation when steady input voltage of high-voltage-side DC bus is 400V (provided by programmable DC power supply) and load resistance of low-voltage-side DC bus is 0.1Ω (provided by programmable DC electronic load). Here the output current of low-voltage-side DC bus iL is stable at about 120A, the output voltage uLV is about 12V, and the output power of low-voltage-side bus Po is about 1.5kW which meets the requirement of rated power designed, now we have realized  the constant-voltage charging of low-voltage-side DC bus.Figure 9 The voltage waveform in Buck mode operationFigure 10 gives the output voltage waveform of primary voltage and  high-voltage-side DC bus of transformer in boost mode operation when steady input voltage of low-voltage-side DC bus is 12V (provided by low-voltage DC power supply) and load resistance of high-voltage-side DC bus is 105Ω (provided by high voltage resistance load box). Here the output current of high-voltage-side DC bus iH is stable at about 3.7A, the output voltage of high-voltage-side DC bus uHV is stable at about 400V, and the output power of high-voltage-side bus Po is about 1.5kW which meets the requirement of rated power designed, until now we have realized  constant-voltage discharge of high-voltage-side DC bus.Due to the high level at the output, technical problems in the winding process for power transformers and the whole experimental device completing by manual welding, the rate of heat dissipation of power transformer appears to be somewhat low and the parasitic inductance and inductive coupling is also rocking the boat, and then we see the voltage waveform oscillation at zero crossing of transformer voltage in Boost mode moderation. However, under the condition of steady state parameters, this experimental platform can work normally and stably for a long time according to the design requirements and can meet the needs of practical applications.Figure 10 The voltage waveform in Boost mode operationFigure 11 is a schematic diagram of the hardware platform which is mainly composed of main circuit board, control circuit board and corresponding test equipment.Figure 11 physical photographs of experimental devices4 EpilogueAccording to the characteristics of bidirectional DC/DC converter applied in fields of battery and electric vehicle energy storage management, a bidirectional DC/DC converter based on full-bridge push-pull topology is obtained by comparing with different circuit topologies. Different from the traditional state-space average modeling, the method of PWM-switch modeling is used now to build small signal equivalent circuits in different mode operations, and the voltage loop has also been designed and corrected. The high-power constant voltage charging is realized in Buck mode moderation and the high-power constant voltage discharge is also realized in boost mode operation. Both modes can work normally and stably to meet the performance requirements of practical applications, which appear to be in high value at fields of battery and electric vehicle energy storage management. Book SuggestionSoft-Switching PWM Full-Bridge Converters: Topologies, Control, and DesignJun 23, 2014This book intends to describe systematically the soft-switching techniques for pulse-width modulation (PWM) full-bridge converters, including the topologies, control and design, and it reveals the relationship among the various topologies and PWM strategies previously proposed by other researchers. The book not only presents theoretical analysis, but also gives many detailed design examples of the converters.---by Xinbo RuanPower Electronics: Converters and RegulatorsOct 28, 2016This book is the result of the extensive experience the authors gained through their year-long occupation at the Faculty of Electrical Engineering at the University of Banja Luka. Starting at the fundamental basics of electrical engineering, the book guides the reader into this field and covers all the relevant types of converters and regulators. Understanding is enhanced by the given examples, exercises and solutions. Thus this book can be used as a textbook for students, for self-study or as a reference book for professionals.---by Branko L. Dokić and Branko BlanušaPulse-Width Modulated DC-DC Power ConvertersOct 26, 2015With improved end-of-chapter summaries of key concepts, review questions, problems and answers, biographies and case studies, this is an essential textbook for graduate and senior undergraduate students in electrical engineering. Its superior readability and clarity of explanations also makes it a key reference for practicing engineers and research scientists. Following the success of Pulse-Width Modulated DC-DC Power Converters this second edition has been thoroughly revised and expanded to cover the latest challenges and advances in the field.---by Marian K. Kazimierczuk Relevant information "Modeling and Control of Full Bridge Push-Pull Bi-Directional DC/DC Converter"About the article "Modeling and Control of Full Bridge Push-Pull Bi-Directional DC/DC Converter", If you have better ideas, don't hesitate to  write your thoughts in the following comment area. You also can find more articles about electronic semiconductor through Google search engine, or refer to the following related articles:How to Learn Analog Circuit DesignLook Forward to the Future of Semiconductor
kynix On 2018-05-17   1329

Kynix

Kynix was founded in 2008, specializing in the electronic components distribution business. We adhere to honesty and ethics as our business philosophy and have gradually established an excellent reputation and credibility in our international business. With the accurate quotation, excellent credit, reasonable price, reliable quality, fast delivery, and authentic service, we have won the praise of the majority of customers.

Follow us

Join our mailing list!

Be the first to know about new products, special offers, and more.

Kynix

  • How to purchase

  • Order
  • Search & Inquiry
  • Shipping & Tracking
  • Payment Methods
  • Contact Us

  • Tel: 00852-6915 1330
  • Email: info@kynix.com
  • Follow Us

authentication