ram Related Articles
Stay Ahead with Expert Electronics Insights,
Industry Trends, and Innovative Tips
- Electronic Components
- News Room
- General electronic semiconductor
- Components Guide
- Sort by
- Robots
- Transmitters
- Capacitors
- IC Chips
- PCBs
- Connectors
- Amplifiers
- Memory
- LED
- Diodes
- Transistors
- Battery
- Oscillators
- Resistors
- Transceiver
- RFID
- FPGA
- Mosfets
- Sensor
- Motors, Solenoids, Driver Boards/Modules
- Relays
- Optoelectronics
- Power
- Transformer
- Fuse
- Thyristor
- potentiometer
- Development Boards
- RF/IF
- Semiconductor Information
- Sensors
- PCB
- transistor
IntroductionEarthing (also known as grounding) refers to the process of transferring the immediate discharge of the electrical energy directly to the earth by the help of the low resistance wire, for safety and functional purposes. Generally, the "ground" of electronic equipment has two meanings: one is to connect to the "earth". Taking the earth as the zero potential, connecting the metal shell of electronic equipment and the circuit reference point to the earth can protect the safety of equipment and personnel, such as protective earthing, lightning protection earthing, etc. In addition, the earthing in the weak current system does not necessarily mean the ground connected to the earth in the true sense. It has the effect of improving the stability of the system, shielding and protecting the electromagnetic compatibility of the system, and it can also be connected to the "earth" when necessary.What is Electrical Earthing?CatalogIntroductionⅠ Earthing Basic1.1 Electrical Earthing1.2 Earthing SymbolsⅡ What Are the Types of Earthing?Ⅲ Why Is Electrical Earthing Important?Ⅳ Earthing Q&A You Should KnowⅠ Earthing Basic1.1 Electrical EarthingAn earthing system (UK and IEC) or grounding system (US) connects specific parts of an electric power system with the ground. Earthing is a therapeutic technique that involves doing activities that “ground” or electrically connect you to the earth. In modern earthing concepts, for line engineers, the meaning of this term is usually a reference point of line voltage; for system designers, it is often a cabinet or rack; for electrical engineers, it is safe earthing or connecting to the earth. A more general definition is a low impedance path for current to return to its source. Note that the requirements are "low impedance" and "path".1.2 Earthing SymbolsPE, PGND, FG: Protective ground or chassisBGND or DC-RETURN: Power supply (battery) returnGND: Work groundDGND: Digital groundAGND: Analog groundLGND: Lightning protection groundⅡ What Are the Types of Earthing?There are many types of earthing, including single-point earthing, multi-point earthing and mixed types of earthing. Among them, single-point earthing is divided into series earthing and parallel earthing. Generally speaking, single-point earthing is used for simple circuits, such as earthing distinctions between different functional modules, and low-frequency (f<1MHz) electronic circuits. When designing high frequency (>10MHz) circuits, multi-point earthing or multilayer boards (complete ground plane) should be used. The following are four specific earthing methods.1. Earth FloatingIn electronic design, a commonly used method is floating technology. In this method, the signal ground of the circuit board is not connected to the external public ground, thereby ensuring good isolation of the circuit. The circuit is well isolated from the external ground system and is not easily affected by the interference on the external ground system. However, static electricity is easy to accumulate on the circuit and cause electrostatic interference, which may generate dangerous voltage.Small-scale low-speed (<1mhz) equipment can use earth floating, a single-point connection to the ground by the metal shell.2. Single-point earthing in SeriesThis kind of earthing method is relatively simple, and there is no need to pay so much attention to the circuit board design. So it will be used more. However, this kind of circuit will have common impedance coupling, causing each circuit module to affect each other.3. Single point earthing in ParallelThis method of earthing, although getting rid of the common impedance coupling problem of series single-point earthing, but in actual use, it will introduce too much earthing wire annoying, as to which one needs to be comprehensively evaluated in the actual process. If the circuit board area allows, use the parallel mode, and if the connection between the various circuit modules is kept simple, then use the series mode. In general, there are power modules, analog circuit modules, digital circuit modules and protection circuit modules in the downloaded board. In this case, I use a parallel single-point earthing method.4. Multi-point EarthingMulti-point earthing is used more in daily circuit design, especially in multi-module circuit design. This earthing method can effectively reduce high-frequency interference problems, but it is also prone to cause earthing loops. This point must be fully considered in the design to improve the circuit stability. The working ground of small high-speed (>10MHz) equipment should be grounded at multiple points with its metal casing. The distance between earthing points should be less than 1/20 of the wavelength of the highest operating frequency, and the metal casing should be connected to the ground at a single point.In short, in the design of electronic circuits, the most important point is to reduce the loop area of the circuit, to improve the stability of electronic design and the EMC design of electronic systems. In the actual design, have comprehensive evaluation of the above various earthing technologies to achieve the purpose of improving system stability.Ⅲ Why Is Electrical Earthing Important?As for earthing function, the introduction of earthing technology was originally a protective measure to prevent electrical or electronic equipment from being struck by lightning. The purpose was to introduce the lightning current generated to the ground through the lightning rod, thereby protecting the building. At the same time, earthing is also an effective means to protect personal safety. When the phase line touches the equipment shell caused by some reason (such as poor insulation of wires, aging of wiring, etc.), the equipment shell will have dangerous voltages. The generated fault current will flow through the neutral line to the ground, thereby playing a protective role. With the development of electronic communication and other digital fields, it is no longer sufficient to consider only lightning protection and safety in the earthing system. For example, in a communication system, the interconnection of signals between a large number of devices requires each device to have a reference ground as the signal reference ground. And with the complexity of electronic equipment, the signal frequency is getting higher and higher. Therefore, in the earthing design, special attention must be paid to electromagnetic compatibility issues such as mutual interference between signals. Otherwise, improper earthing will seriously affect the reliability of system operation. Also, the concept of "earthing" has also been introduced in the high-speed signals return technology. Ⅳ Earthing Q&A You Should KnowThe following questions relay on electrical earthing science and grounding physics to explain how electrical charges from the earth can have huge effects on our life. And how do you discharge the electrical energy directly to the earth by earthing technology. Also these Q&A give you considerable attention for the earthing system design and installation.1. What is the difference between earth earthing and electrical earthing?The earth is an object with very low resistance and very large capacitance. It has the ability to absorb infinite charge, and meanwhile can maintain the potential unchanged. Therefore, it is used as the reference potential of a system electrically, that is electrical earthing. In addition, in electronic equipment, when transmitting current and signal conversion at various levels of circuits, a reference potential is required to prevent interference from external signals. This potential is called logical ground or floating ground.2. What is the difference between the ground potential and the logical ground potential?Since the earth can absorb infinite electric charge, the potential of the earth looks macroscopically zero. Due to the influence of the natural electric field and the artificial electric field in the earth, the potential of each point of the earth is different. In engineering, 20m away from the artificial electric field is regarded as zero potential (earthing potential). The electrical ground potential is related to the current injected into the ground by the electrical system. When a large current flows into the electrical ground, the electrical ground potential may reach a very high voltage, especially when the lightning current flows into the electrical ground. The instantaneous potential of the electrical ground can reach 100,000 volts. Therefore, a separate lightning protection earthing point cannot be located in a place where have pedestrians.3. What is the shell?Due to the damage of the insulation layer of the wire, the phase wire is in contact with the outer shell of the electrical equipment, which is called a bumping shell. If the insulation of the phase wires and the enclosure of the electrical equipment does not meet the specified requirements, the equipment cannot be put into use. The reason for the insulation drop may be moisture or damage to the insulation layer, which can be analyzed according to the environment in which the circuit equipment is used.4. What is the step voltage?When an electrical device has a short-circuit fault to the ground, the fault current flows from the fault ground to the ground electrode and returns to the power source. Therefore, an electric field is generated around the ground of the fault point and the ground electrode, which is away from the ground of the fault point or the ground of the ground electrode. The closer, the higher the potential, and the farther, the lower the potential. When the distance between the two feet of a person is about 0.8 meters, standing in this electric field, because the two feet are at different potential points, there will be a potential difference. This potential difference is called the step voltage.5. What is contact voltage?When the insulation of electrical equipment is damaged and a short-circuit occurs to the shell, people who touch the electrical equipment will have the risk of electric shock. To define the degree of danger, the potential of the equipment 0.8 meters away from the horizontal direction of the electrical equipment when it fails is measured. The potential difference between the two is called the contact voltage.6. What is the earthing resistance difference between the earthing electrode and the equipment?The ratio of the earthing voltage to the earthing current is called the earthing resistance of the earthing electrode. When measuring the earthing electrode resistance in a project, an ac voltage is artificially applied to the earthing electrode, and then the current flowing into the earthing electrode is measured. The ratio of the two is the earthing resistance. The earthing resistance of the equipment is the sum of earthing wires resistances.7. What are the classifications of earthing functions?Generally divided into two categories: protective earthing and functional earthing1) Protective earthing can be divided into the following 4 types:Protective earthing: earthing the exposed conductor part of the equipment is called protective earthing. Its purpose is to prevent electrical equipment insulation damage or leakage, which may cause electric shock when people touch it.Lightning earthing: Lead lightning into the earth to prevent electric shock or other property damage.Anti-static earthing: Introduce static charges into the ground to prevent the accumulation of static electricity from causing harm to the human body and equipment.Anti-corrosion earthing: Bury a metal body underground as a sacrificial anode or cathode to protect the metal body connected to it, such as a metal oil pipeline.2) Functional earthing can be divided into the following 4 types:Working earthing: In order to ensure the operation of the power system, earthing is done at an appropriate place in the power system, which is called working earthing. In an AC system, this point is generally a neutral point.Logic earthing: To obtain a stable reference voltage, the appropriate metal parts in the electronic equipment are used as the reference zero potential, and the electronic parts that need to obtain the zero potential are connected to this metal part. This method is called logic earthing.Shield earthing: Ground the metal shell or the metal net to protect the electronic equipment in the shell or the net from external electrical interference, or prevent the electrical equipment in the shell or the net from causing interference to external electronic equipment.Signal earthing: A earthing method set to ensure that the signal has a stable reference potential.8. What is working ground?In order to ensure the safe operation of the electrical device, the earthing of any point (usually the neutral point of the power supply) of the device conductive part is called the working ground.9. What is the relationship between the safety voltage and the use environment?The safety voltage is to prevent personal electric shock. The degree of electric shock is related to the impedance of the human body, and the impedance of the human body has a great relationship with the contact condition. Under different conditions, it is different.The relationship between human body impedance and contact conditions is usually divided into three categories:1) High impedance: dry skin, dry environment, high impedance ground2) Low impedance: moist skin, humid environment, low impedance ground3) Zero impedance: for example, the human body is immersed in water10. What is the difference between short circuit and ground fault?The electrical connection between mutually insulated live conductors due to insulation damage is called a short circuit. For example, between phase wires of different phases, or between a phase wire and a neutral wire, exist an electrical connection, there may be a short circuit. The electrical connection error between the live conductor and the earth is called a ground fault. In addition, live conductors refer not only to the phase line, but also the neutral line. The ground refers to the metal shell of grounded electrical equipment, non-electrical metal pipes and the earth.11. What parts of the earthing device consist of?earthing device is a general term for earthing electrode and earthing wire.The earthing electrode is a conductor buried in the soil or concrete foundation for dissipating current. It can be divided into two types: natural earthing electrode and artificial earthing electrode.There are several types of natural earthing electrodes: the underground metal plumbing systems, the metal structure of the building and the reinforced concrete structure.The artificial earthing electrode should adopt horizontally laid round steel, flat steel, metal earthing plate, and vertically laid angle steel, steel pipe, round steel, etc.12. What are the measures to prevent direct electric shock?Insulate charged objectsUse shields or barriers to block the human body from charged objectsUse leakage switch as additional protection13. What are the measures to prevent indirect electric shock?Set up automatic power-off deviceEquipment with double insulationTake ungrounded local potential connectionElectrical isolation14. What are the types of earthing systems for high-voltage systems?1) Direct earthing, that is, the neutral point of the transformer or generator is connected to the earthing device directly or through a small resistance (such as a current transformer). This kind of earthing method has a large earthing current when a single-phase earthing short circuit occurs, so it is also called the large current earthing system.2) Ungrounded, the neutral point of the transformer in this system is not grounded or connected to earthing equipment such as arc suppression coils, large resistances, and the earthing device.15. Can the natural earthing electrode be used for the earthing of DC electrical devices?The earthing of AC electrical installations should make full use of the natural earthing electrode buried in the ground. For the earthing of DC electrical installations, it is not allowed to use the natural earthing electrode as the PE wire, earthing wire and earthing electrode of the current pattern. The earthing device is connected to the natural earthing. The distance between earthing devices and AC electrical devices shall not be less than 1m to avoid electrical corrosion.16. What is the function of total equipotential bonding?The function of total equipotential bonding (MEB) is to reduce the contact voltage of indirect contact electric shock in the building and different metal parts with different potential, which eliminate the dangerous fault voltage introduced from outside the building through electrical lines and various metal pipes.17. What is supplementary bonding?The two conductive parts are directly connected with wires to make the contact voltage of the fault drop below the contact voltage limit, which is called supplementary or additional equipotential bonding (earthing). When the earthing device fails, the indirect contact protection conditions for automatically cutting off the power supply cannot be met, supplementary bonding should be set. It should also be installed in places with special requirements such as bathrooms, hospitals, and swimming pools.18. What is local equipotential bonding?Local equipotential bonding (LEB) refers to the connection of multiple supplementary equipotential bonding through the bonding terminals in a local board, which is called local equipotential bonding.19. How to check the conductivity of equipotential bonding?1) Welding quality inspection2) Bolt connection quality inspection3) Measure resistance between branch and trunk20. What are the characteristics of arc short circuits?There are two forms of short circuit and ground fault: metallic and arc short. The current of metallic short circuit is very large, which can make the overcurrent protector (circuit breaker or fuse) act in time and the fault is not easy to go on. The short circuit point of arc short circuit has arc or electric spark and the impedance is large, therefore, the short circuit current is small. So overcurrent protection will not take effect. However, the temperature of the arc short-circuit point is very high, which can reach thousands of degrees Celsius locally. It is very easy to ignite the substances around the short-circuit point and cause a fire.Arcing short circuit not only occur in electrical and earthing faults, but poor connections between wires can also cause it. For example, cause flickering of incandescent lamps or interference for TV sets. At this time, you must check whether the connection point of the line is reliable. Frequently Asked Questions about Electrical Earthing System Basics1. What is elecrical earthing and types of earthing?Earthing is the first step towards electrical safety. ... Earthing is done to provide safety to user from electric shock. It is a set of conductors connected in series or in parallel in order to dissipate the potential difference immediately into the ground. The wire connected from equipment to earth called earthing wire. 2. What is difference between earthing and grounding?The key difference between earthing and grounding is that the term “Earthing” means that the circuit is physically connected to the ground which is Zero Volt Potential to the Ground (Earth). Whereas in “Grounding” the circuit is not physically connected to ground, but its potential is zero with respect to other points.Difference between Earthing and Grounding 3. Is grounding the same as earthing?The key difference between earthing and grounding is that the term “Earthing” means that the circuit is physically connected to the ground which is Zero Volt Potential to the Ground (Earth). Whereas in “Grounding” the circuit is not physically connected to ground, but its potential is zero with respect to other points. 4. What is the purpose of earthing?Earthing is used to protect you from an electric shock. It does this by providing a path (a protective conductor) for a fault current to flow to earth. It also causes the protective device (either a circuit-breaker or fuse) to switch off the electric current to the circuit that has the fault. 5. Which wire is used for earthing?copper wiresEarthing Lead or Earthing JointEventhough copper wires are generally used as earthing lead, copper strips are preferred for high installation as it can carry higher values of fault current due to its wider area.
kynix On 2021-03-01
IntroductionAn operational amplifier, or op amp is used in a wide variety of applications in electronics. It generally comprises a differential-input stage with high input impedance, an intermediate-gain stage, and a push-pull output stage with a low output impedance. Common operational amplifier has two input pins and one output pin. Its basic role is to amplify and output the voltage difference between the two input pins. So what are these op-amp parameters meaning? This note tells you the typical parameters of op-amp and their definitions, also there have several examples with specific values to explain deeply for you. CatalogIntroductionⅠ How Does An Op Amp Work?Ⅱ Understanding Basic Op-amp Parameters2.1 What are the Parameters of Op Amp?2.2 Questions about Op Amp Important ParametersⅢ Common Op-amp ICs Datasheet OverviewⅣ ConclusionⅠ How Does An Op Amp Work?An op-amp is a multi-stage , direct coupled, high gain negative feedback amplifier. It is basically a three-terminal device which consists of two high impedance inputs. Ideally, it only amplifies the difference in voltage between the two, also called differential input voltage. Op-amps are still a primary building block for analog systems, performing tasks like amplification, active filtering, and signal transformation. In digital systems, op-amps are used in buffers, analog-to-digital converters, digital-to-analog converters, and regulated power supplies, to name a few applications.Ⅱ Understanding Basic Op-amp ParametersOp-amps are linear devices that are ideal for DC amplification and are used often in signal conditioning, filtering or other mathematical operations. So understanding its basic parameters is important to employ it well in circuits.Parameters Of Op-Amp2.1 What are the Parameters of Op Amp?Gain Bandwidth1) Gain bandwidth product: Due to parasitic junction capacitance and minority-carrier change storage in devices, the voltage gain of op amp decreases at high frequencies, it refers to the bandwidth and gain product.2) Unity gain bandwidth: As the input signal of the frequency increases, the open-loop gain drops off until it finally reacts to the value 1. The frequency at which the gain reduces to 1 is defined as unity gain frequency or unity-gain bandwidth.Input Offset VoltageIt is a very small voltage applied at the outputs, to make the output terminal zero of the operational amplifier. It reflects the symmetry of the the op amp circuit. The better the symmetry, the smaller the input offset voltage.Input Offset Voltage DriftThe input offset voltage drift is also called the temperature coefficient. In a given temperature range, it is the ratio of the change in the input offset voltage to the temperature change. This parameter is actually a supplement to the input offset voltage. Within a given operating range, the magnitude of the drift of the amplifying circuit depends on the temperature changes.Input Bias CurrentWhen the output current voltage of the op amp is zero, input bias current refers to the average value of the bias current of the two input terminals that flows into the inverting and non-inverting input terminals of the Op-Amp. It has a greater impact on the places where the input impedance is required, and it is generally related to the manufacturing process. The smaller the input bias current the smaller the drift.Input Offset CurrentWhen the output current voltage of the op amp is zero, input offset current means the difference between the bias currents of the two input terminals. It also reflects the symmetry of the circuit inside the op amp. The better the symmetry, the smaller the input offset current.Input Resistance1) Differential mode input impedance: when the operational amplifier is working in the linear region, it is the ratio of the voltage change at the two input terminals to the corresponding current change. It includes input resistance and input capacitance, and only refers to input resistance at low frequencies.2) Common mode input impedance: It is the ratio of the input current change when the op amp is inputting a signal, that is, the same signal is input at the two input terminals of the op amp. At low frequencies, it appears as a common-mode resistance.Output ResistanceWhen the operational amplifier works in the linear region, a voltage signal is added to the output terminal of the operational amplifier, output resistance means the ratio of the voltage change to the corresponding current change. At low frequencies, it only refers to the output resistance of the op amp. This parameter needs to be tested in an open loop state.Voltage Gain1) Open-loop gain: the amplification factor of the op amp without negative feedback (in open loop state). The ideal value is infinite, generally about thousands to tens of thousands of times, and it represents by dB and V/mV.2) Closed-loop gain: in the case of negative feedback, it refers to the amplifier magnification.Voltage SwingWhen the op amp is working in the linear region, voltage swing is the maximum voltage amplitude that the op amp can output under the specified load and the current power supply voltage.Input Voltage Range1) Differential mode input voltage range: The maximum differential mode input voltage is defined as the maximum allowable input voltage difference between the two input terminals of the operational amplifier. When the input voltage difference of the op amp exceeds it, the input stage of the op amp may be damaged.2) Common mode belongs to the rabbit voltage range: when the operational amplifier is working in the linear region, when the common mode rejection ratio of the operational amplifier deteriorates significantly is the maximum common mode input voltage. It limits the maximum common-mode input range in the input signal, therefore, special attention is required in the case of interference.Slew RateThe slew rate of the op amp is defined as the input of a large signal (including a step signal) to the input under the closed loop condition. It indicates how fast the output of OP-AMP can change in response to change in input frequency. The output rise rate of the op amp is measured from the output of the op amp. Since the op amp is in a closed loop state during conversion, the feedback loop of the op amp does not work, that is to say, the slew rate has nothing to do with the closed loop gain.CMRRThe Common Mode Rejection Ratio (CMRR) is defined as the ratio of the differential voltage gain to the common-mode voltage gain.Unity GainA unity gain amplifier is an amplifier that has a gain of 1 that also means there is no gain. The output voltage will be the same as the input voltage it is commonly known as a voltage follower amplifier.Common Mode Rejection RatioWhen the op amp works in the linear region, it means the ratio of the differential mode gain of the op amp to the common mode gain. It is an extremely important indicator, it suppresses differential mode interference signals. Since the common-mode rejection ratio is very large, the common-mode rejection ratio of most op amps is recorded and compared in decibels.Supply Voltage Common Mode Rejection RatioWhen the op amp works in the linear region, it means the input offset current of the op amp varies with the supply voltage. Supply voltage common mode rejection ratio reflects the impact of power supply changes on the output of the op amp. Pay special attention when used for DC signals or small signals.Equivalent Input VoltageA well-shielded op amp without signal input, any AC interference voltage generated at its output end, when this noise is converted to the input of the op amp, it is called the input noise voltage (sometimes also expressed by noise current).2.2 Questions about Op Amp Important ParametersWhy do op amps need negative voltage?Op-amps themselves don't have a 0V connection but their design assumes the typical signals will be more towards the center of their positive and negative supplies. Thus, if your input voltage is right at one extreme or forces the output toward one supply, chances are it won't work properly. Why op amp has high gain?The gain of an op amp represents how much greater in magnitude its output will be than its input, hence its amplification factor. This is usually defined as an open-loop gain or large signal voltage gain. Why Positive feedback is not used in op amp?In an op-amp circuit with no feedback, there is no corrective mechanism, and the output voltage will saturate with the tiniest amount of differential voltage applied between the inputs. What is CMRR?The Common Mode Rejection Ratio (CMRR) is defined as the ratio of the differential voltage gain to the common-mode voltage gain. CMRR is infinity. Why CMRR should be high?A high CMRR is required when a differential signal must be amplified in the presence of a possibly large common-mode input, such as strong electromagnetic interference (EMI). An example is audio transmission over balanced line in sound reinforcement or recording. What is the maximum gain of op amp?The maximum gain is the open loop gain. It depends on the opamp model, and can go anywhere from 60 dB to 120 dB voltage gain. The open-loop bandwidth is however very small. Another issue is that this gain is very variable between different parts of the same product number due to variations. What is slew rate of op amp?Slew rate (SR) is the maximum rate of voltage change that can be generated by the op-amp's output circuitry. It is measured as voltage relative to time, and the typical unit used in datasheets is volts per microsecond (V/µs). SR is infinity, which means the ideal op-amp will produce a change in the output instantly in response to an input step voltage. What is bandwidth of an operational amplifier?The operational amplifiers bandwidth is the frequency range over which the voltage gain of the amplifier is above 70.7% or -3dB (where 0dB is the maximum) of its maximum output value as shown below. Is higher slew rate better?Higher slew rates are not always better: Higher slew rate makes for higher operating current. This means higher power consumption. Faster slew rate will make higher bandwith. Ⅲ Common Op-amp ICs Datasheet OverviewLM741The LM741 series are general-purpose operational amplifiers which feature improved performance over industry standards like the LM709. It is intended for a wide range of analog applications. It has only one op-amp inside. An operational amplifier IC is used as a comparator which compares the two signal, the inverting and non-inverting signal.Figure 1. LM741 Op Amp PinoutTable 1: LM741 SpecificationsMax supply voltage: ±22 VVoltage gain: 200V/mVMax input voltage: ±15 VBuilt-in output short circuit protectionMax output short circuit current is 40 mA.Input resistance: 6MMax low offset voltage of 6mv and can drift 15 µV/°CApplications include comparator, dc amplifier, summing amplifier, integrator or differentiators and active Filters.Max input offset current of 70nA and can drift up-to 0.5 nA/°C.Max Bandwidth is 1.5Mhz;Max Slew rate is 0.7 V/us.Max CMRR is 90 dB.Similar Products: UA741, µA741Max peak output voltage swing is 16VOperating temperature range –50 to 125 °C LM709 SeriesThe LM709 series is a monolithic operational amplifier in tended for general-purpose applications. The precursor to the popular LM741 is the LM709. The 709 had no internal frequency compensation, unlike the 741. Frequency compensation is used to purposely limit an operator's bandwidth. As the input frequency increases, the operator's phase shift also increases. This can contribute to unnecessary oscillation, as an unintended phase-shift oscillator forms the feedback network.Figure 2. LM709 Op Amp PinoutTable 2: LM709 SpecificationsMax supply voltage: ±18VInput resistance: 750KMax input voltage: ±10VOutput resistance: 150ΩMax low offset voltage of 6mv and can drift 6 µV/°CApplication includes voltage follower, basic comparator, multivibrator and frequency generator.Max input offset current of 500nA and can drift up-to 22.8 nA/°CPackage: TO-5, Pin Nb=8Max CMRR is 70dB.Similar parts: OP77, UA70Peak output voltage swing is 24VOperating temperature range –55 to 125 °C LM1458LM1458 is a dual general purpose Operational Amplifier (Op-amp). Its has two built-in amplifiers having common power supply, and short circuits protected and require no external components for frequency.Figure 3. LM1458 Op Amp PinoutTable 3: LM1458 SpecificationsMax supply voltage: ±18 VInput resistance: 1MΩMax input voltage: ±15VMax CMRR is 90dBvoltage gain: 15V/mVbuilt-in output short circuit protectionMax low offset voltage of 6mv and can drift 15 µV/°CInput offset current of 300nA max and can drift up-to 0.5 nA/°CMax peak output voltage swing is 14V.Max bandwidth is 1MHz.Operating temperature range 0 to 70 °CApplications include summing amplifiers, portable devices, comparators, integrators, etc.Similar Products: MC1458Packages have TO-CAN, DSBGA, SOIC and PDIP. LM324The LM324 series are low−cost, quad operational amplifiers with true differential inputs. They have several distinct advantages over standard op amps. It is a single supply, high gain, internally frequency compensated quad op amp. And it can be operated from a single or split power supplies.Figure 4. LM324 Op Amp PinoutTable 4: LM1324 SpecificationsMax supply voltage: 32 VOutput resistance: 350ΩVoltage gain: 100 V/mVMax output short circuit current is 60 mAInput bias current: 100nABuilt-in output short circuit protectionMax low offset voltage of 3mv and can drift 30µV/°CMax input offset current of 30nA and can drift up-to 300 pA/°CMax CMRR is 85dB.Max peak output voltage swing is 16V.Bandwidth is 1MHzOperating temperature range 0 to 70 °CPackages: 14-pin PDIP, 14-pin CDIP, 14-pin SOIC, and 14-pin TSSOP NE5532Compared to the standard dual op amps, the NE5532 is a Dual Low Noise Op-Amp in 8-pin package commonly used as amplifiers in audio circuits for its noise immunity and high output drive capability. The Op-Amp is internally compensated for high unity gain with maximum output swing bandwidth, low distortion and high slew rate.Figure 5. NE5532 Op Amp PinoutTable 5: NE5532 SpecificationsMax supply voltage: ± 15VInput bias current: 1000nAMax supply current: 10mALow offset voltage: 5 mVInput offset current: 200nABuilt-in output short circuit protectionMax output short circuit current is 60 mAInput resistance: 300KΩMax CMRR is 100dB.Output resistance: 0.3ΩMax peak output voltage swing is 26V.Max bandwidth is 10Mhz.Max slew rate is 9 V/us.Operating temperature range -65 to 150 °CApplications include Av Receivers, Audio mixer, High-performance audio preamplifier and many more.Ⅳ ConclusionOp amps are used in a wide variety of applications in electronics. Some of the more common applications are: as a voltage follower, selective inversion circuit, a current-to-voltage converter, active rectifier, integrator, a whole wide variety of filters, and a voltage comparator. Based on your circuit requirements, you should check out datasheets of different op-amps and select one.
kynix On 2021-01-15
Ⅰ IntroductionOne of those imperative passive electrical components that are present in a large range of circuits is capacitors. If you are a DIY enthusiast who is enthusiastic about electronic circuits, it is a must to understand the condenser types to use them correctly in suitable circuits. We help you decode and understand the uses of one of the most common types of capacitors are called the film capacitors here in this article. The fundamentals of capacitors, their forms and when to use them, have already been discussed. Notice that Film Capacitors are known by several names, Polyester Capacitors and Mylar Capacitor are some common ones, all of them, in general, are covered in this article. Capacitors can generally be divided into two broad categories: polarized and nonpolarized. Due to its flexibility and low cost, the film capacitor is a form of non-polarized capacitor and is very common. Read on to learn more about a film condenser: what a film condenser is, how it is made, and what makes it so famous. Let's start with this little passive gadget with a brief introduction.CatalogⅠ IntroductionⅡ Definition of Film CapacitorsⅢ A Variety of CapacitorsⅣ Brief History of Film CapacitorsⅤ Types of Film Capacitors and Their Applications 5.1 Film/Foil Capacitors 5.2 Metalized Film CapacitorsⅥ Features and Applications of Film CapacitorsⅦ How is Film Capacitor different from Electrolytic Capacitor and Ceramic Capacitor?Ⅷ Construction of Film CapacitorⅨ FAQⅡ Definition of Film CapacitorsThe film capacitor is a non-polarized capacitor and thin plastic films are used to produce its dielectric. These plastic films are often metalized and are available under the name of 'metalized condenser' on the market. Such capacitors are also often referred to as plastic capacitors or metalized capacitors. A Thin Film Capacitor is nothing but a plastic film with bipolar capacitors as their dielectric. To form a roll or a candy-like rectangular shape, these films are either metalized or just put in layers. Polypropylene(PP) /Polyethylene terephthalate (PET)/ Polytetrafluoroethylene(PTFE)/Polyphenylene Sulfide (PET) are the dielectrics widely used (PPS) The primary benefit of using a film capacitor is that it has a very low distortion factor and excellent frequency features. The wide variety of plastic film used for various film condensers makes them flexible. These capacitors often do not wear off easily and are ideal for applications such as coupling/decoupling circuits, ADC, audio circuits, and many more for high voltage and high-frequency applications. Bypass and decoupling capacitors, which are popular applications for condensers, have also been addressed previously.Ⅲ A Variety of CapacitorsWe need to understand the context behind the common words Film Capacitor, Polyester Capacitor, Mylar Capacitor, and Polypropylene Capacitor before we continue with our post. There are several types of film capacitors depending on the type of dielectric plastic material used in the capacitor, one of which is the most widely used polyester condenser and polypropylene condenser. Often known as Polyester Film Capacitors, the polyester capacitor has a dielectric material made of a polymer named polyethylene terephthalate (PET). This is why often this capacitor is referred to as the PET Film Capacitor. There are several Polyester Capacitor manufacturers, of which Hostaphan is the leading one. The Polyester Capacitor is also often called a Mylar Capacitor to address the vendor term. Below, a typical Mylar capacitor is shown.Another type of film capacitor in which the dielectric material is made of polymer caller polypropylene (PP), is the polypropylene film capacitor, hence the name Polypropylene Film Capacitor or PP Film Capacitor. Below is a typical polypropylene capacitor.Similarly, depending on the type of polymer used for the dielectric, there are more than 10 different types of film capacitors, the properties of which vary slightly, but the overall functionality and application almost remain the same. We will get into the specifics later, but let's dive into history before that.Ⅳ Brief History of Film CapacitorsPaper capacitors were used in the decoupling circuits before film capacitors came into the picture. Impregnated paper that was placed with metal strips and rolled into cylindrical forms was used by paper condensers. Since these capacitors had paper as a dielectric, however, they were not only likely to be vulnerable to environmental defects and were very voluminous in size. Scientists have therefore started to look for a solution that would mitigate these problems. It was at a time when the plastic industry was booming and scientists discovered how long-term stability in terms of its electrical parameters was given by the use of complex plastic films as a dielectric. As multilayers of paper were replaced by only a few sheets of plastic, it also helped to reduce the bulk. As technology progressed, thinner plastics with high reliability decreased the size of these capacitors.Ⅴ Types of Film Capacitors and Their ApplicationsThe plastic industry saw growth in the production of thinner and more robust goods soon after the first film capacitor was introduced. Different kinds of plastic film capacitors have been used as a dielectric to accommodate various circuit applications over the years. There are several film condensers in which the plastic films are actually put between the aluminum foils and there are others in which the plastic film is metalized by a phase in which the metal is coated on the film itself. In general, based on construction, film capacitors can be divided narrowly into two groups. Notice that only the construction is based on the classification.5.1 Film/Foil CapacitorsThe film/foil capacitor, as the name implies, uses plastic films as a dielectric and is mounted within two layers of aluminum foil electrodes. These interleaved layers are so organized that they do not touch each other with the metallic layers. Such capacitors can be either non-inductive or inductive.In such a way that the aluminum foils are located in the middle of the two films, an inductive film foil capacitor is wound. The aluminum foils are not directly attached but through a leading wire that carries the entire winding. A pictorial representation of it is shown in Figure 1.In a non-inductive fill foil capacitor, the aluminum foils are arranged in such a way that each foil is positioned to a certain degree out of the films, such as that shown in Figure 2.Plastic Film Capacitor Characteristics:• High insulation resistance• Good capacitance stability• High efficiency even at high frequency• Dielectric used: Polypropelene(PP)/ Polyethylene terephthalate (PET)/Polytetrafluoroethylene(PTFE)Plastic Film Capacitor ApplicationThe film/foil capacitor application depends on the type of dielectric used. For coupling, decoupling, and bypassing, PET Film/foil capacitors are great. PP Film/Foil (PP) capacitors are a good choice for use in circuits requiring high switching frequencies, such as resonant and oscillator circuits, power supplies, etc.5.2 Metalized Film CapacitorsThe primary distinction between a film foil capacitor and a metalized capacitor is that the metallic electrodes are fused into either side of the dielectric plastic in the latter instead of layering. While it raises the cost and also adds a step in the production process, it has greater reliability and smaller dimensions than in a film foil condenser. To get the desired capacitance value, the thickness of the plastic film can be as low as 0.6μm.Metalized Film Capacitor Characteristics:• Self-healing property: This property helps the capacitor to repair itself if the electrodes are exposed to each other instead of being short-circuited. This increases the capacitor reliability• Compact in dimension and form• Polypropylene(PP)/polyethylene terephthalate(PET)/ polytetrafluoroethylene(PTFE)/ polyphenylene sulfide Dielectric used: polypropylene(PP)/polyethylene terephthalate (PET) (PPS)Metalized Film Capacitor Application:In electronic control circuits, including DC link circuits, pulse circuits, switching circuits, etc., metallic film capacitors are commonly used. In decoupling and filtering applications, the low power metalized film capacitor finds use.Ⅵ Features and Applications of Film CapacitorsThe film capacitors often provide other features, in addition to the normal use of condensers to accumulate electrical charges. In high-frequency circuits, their bipolar nature and exceptional frequency characteristics make them famous. The standard capacitance value for these capacitors, in general, ranges from 1nF to 30muF. These small passive parts can have a voltage level of as low as 50 V and as high as 2 kV, so they can be used in a wide variety of applications. One of the fascinating facts is that various types of plastic film are used by these film capacitors as a dielectric. In general, each type of film provides a condenser with different temperature and frequency characteristics. Therefore, one can select the best solution for their needs in their circuits with the correct choice of the dielectric. For example, the PP film capacitor would be the best choice if you are looking for a film capacitor to be mounted in a circuit intended for high-power/high-frequency applications, such as induction heaters, for example. A comparison of the frequency and temperature characteristics of 4 different plastic film dielectrics, namely PP, PPS, PEN, and PET, is shown in the figure below. The only difference is the dielectric material between these capacitors and you will note the shift in temperature and frequency is very obvious.Among other aspects, film capacitors are mainly known for their low dissipation factor, stable capacitance, and high insulation resistance, such as negative temperature and high-reliability characteristics. Hence, for a wide range of applications, they are common choices. These film capacitors generate optimum output from simple sample/hold circuits for ADCs, oscillatory circuits, timers, to finding a position in the coupling/decoupling units of high-end electronic power circuits. Over the past few decades, these capacitors have replaced the use of ceramic and electrolyte capacitors in many circuits in automotive and industrial applications. For some applications, let's compare the film capacitor with the other common capacitors and get to know what makes them a better option.Ⅶ How is Film Capacitor different from Electrolytic Capacitor and Ceramic Capacitor?The first difference between these three capacitors that is quite obvious is the type of dielectric used and their construction. While film capacitors use thin sheets of plastic film, ceramic capacitors, like the dielectric, use sheets made of ceramic material. In nature, both of them are bipolar. On the other hand, electrolytic capacitors have oxides that act as dielectrics and are polar. The differences in their production and dielectrics have an enormous impact on their results. As discussed above, a wide variety of capacitance values are available for plastic film/metalized film capacitors. Ceramic capacitors, on the other hand, are only ideal for circuits that have low requirements for capacitance. For specific applications such as analog signal processing and audio circuits, due to the low distortion factor they offer, film capacitors are preferred over ceramic capacitors. Ceramic capacitors also tend to have high nonlinearities at high capacitances that affect the performance of the circuits. Capacitors with high capacitance and a low cost are favored for applications such as coupling/decoupling circuits. Both electrolytic and film capacitors are also good choices to choose from. The ESR (Equivalent Series Resistance) and ESL (Equivalent Series Inductance) value of the capacitor is another major factor that is considered when designing such circuits. As already discussed, in contrast to electrolytic capacitors, film capacitors have a stronger ESR and ESL performance and a much lower distortion factor and are thus favored over aluminum electrolytic capacitors. Also, if the aging time between these three capacitors is compared, film capacitors appear to avoid the wearing out process between them for the longest time. For high voltage and high-frequency applications, this makes them a safer option.Ⅷ Construction of Film CapacitorThe generic method of development for these capacitors begins with the removal of a thin layer of plastic film. This film's thickness determines the capacitance value. Since the capacitance value increases with a decrease in the gap between the electrodes, the higher capacitance value is thus indicated by the lower film thickness. The standard capacitance value for these capacitors, in general, ranges from 1nF to 30muF. Once the film is removed according to the desired capacitance value and the breakdown voltage, either aluminum or zinc is metalized and rolled over to form a' mother roll.' The films are only interlaced between sheets of aluminum foil to form the roll in the case of a film/foil capacitor. A flow diagram of the different steps involved in producing a metalized film capacitor is shown in the figure below.This roll is then manipulated to accommodate the capacitor size and the desired electrical characteristics by several processes such as slitting, winding and flattening. The projecting electrodes are subjected to a metalizing process called 'Schoopage' until the capacitor obtains its desired shape and size. To create a protective coating on the electrodes, liquefied metals such as zinc, aluminum, or tin are used here. To burn away any existing defects on the electrode surface, the lateral ends of the winding are then sprayed with compressed air and then exposed to a voltage. Since the capacitors can be easily influenced by moisture, silicone oil, or some other insulating fluid is impregnated with the winding. Finally, this winding is prepared to be soldered to the capacitor's metallic terminals. The capacitor is subjected to a final round of protection coating until soldered, where its body is dipped into a protected coating or potted on the outer casing.Ⅸ FAQ1. What is a film capacitor?A film capacitor is a plastic capacitor that is used to construct the dielectric and aluminum or zinc is used to construct the electrodes of the capacitor. 2. Can film capacitors explode when overloaded (like electrolytic)?If the overvoltage is very large you can damage them, eventually burn them, as with any electronic component you abuse. But IMHO explosion of film capacitors is not very likely. The danger when dealing with liquid electrolytic capacitors is that the electrolyte is acid, and if they explode they can cause severe injuries, for instance in the eyes. When they are 'abused' with over-voltage or with high reverse voltage (they are polarized, remember…) the pressure inside increases and they eventually explode. To avoid the pressure increases too much, they have 'escape valves' in the same way as high-pressure kitchen boilers have. In the capacitors those escape valves are thin 'weakened spots' in the plastic cover or there are cross-shaped grooves in the aluminum. 3. What is a film capacitor used for?Film capacitors can also be used in a more conventional way as voltage smoothing capacitors, filters, audio crossovers. They can be used to store energy and release it in a high-current pulse when needed. High-current electrical pulses are used to power pulsed lasers or generate lightning discharges. 4. What is the preferred application of a film capacitor?For particular applications like analog signal processing and audio circuits, film capacitors are preferred over ceramic capacitors due to the low distortion factor which they offer. Also at high capacitances, ceramic capacitors tend to have high nonlinearities which affect the performance of the circuits. 5. How do you determine the polarity of a film capacitor?Based on the height of the capacitor leads we can identify which is negative polarity and which is positive polarity. Capacitor whose terminal is longer is a positive polarity terminal or an anode and the capacitor whose terminal is shorter is a negative polarity or cathode. 6. What is an electrolytic or film capacitor?While the active part of electrolytic capacitors, the so-called wound cell, consists of aluminum (anode and cathode foil), paper, and electrolyte, the film capacitor is made of metal-coated plastic film that builds its electrodes. 7. Can I replace the film capacitor with ceramic?Yes, they are interchangeable, but ceramic disc capacitors are considerably more nonlinear in their voltage and frequency response compared to film capacitors. Ceramic caps can also be microphonic. 8. How do you use a film capacitor?Most power capacitors, the largest capacitors made, generally use polypropylene film as the dielectric. PP film capacitors are used for high-frequency high-power applications such as induction heating, pulsed power energy discharge applications, and AC capacitors for electrical distribution. 9. How long do film capacitors last?The MKP1848 film capacitor has a life quoted as 100000 hrs at 70 degC. The life of a Rubycon BXC series wet electrolytic capacitor is quoted as 12000 hrs at 105degC. By way of the '10 degree rule', we can say that the lifetime of the Rubycon electrolytic capacitor at 70 degC would be 96000 hrs. 10. Do film capacitors degrade?The degradation of metalized film capacitors is a concern in applications exposed to high humidity environments. The metalized electrode layer in metalized film capacitors is very thin, typically less than 50 nm, which is susceptible to corrosion due to the ingress of atmospheric moisture.
kynix On 2021-01-12
IntroductionSeries Circuits and Parallel Circuits are main circuit connections, also a third type of circuit involves the dual use of series and parallel connections in a circuit. Circuit connection is a kind of principle for layout diagram that shows the relationship between components drawn by physical and electrical standardized symbols for research and engineering planning. As we all know, there are two types of circuit we can make, called series and parallel. They provide solutions for analyzing performance, installing electronic and electrical products.CatalogIntroductionⅠ Series Circuits and Parallel CircuitsⅡ Series Circuits and Parallel Circuits Calculation2.1 Resistors2.2 Capacitors2.3 Inductor2.4 Switch2.5 Power Supply2.6 Series and Parallel Circuits RulesⅢ Six Circuit Design Software Tools Introduction3.1 Protel PCB Design Platform3.2 Altium Designer3.3 Quartus II3.4 Electronics Workbench (EWB)3.5 NI Multisim3.6 Allegro PCBⅣ Frequently Asked Questions about Series and Parallel CircuitsⅠ Series Circuits and Parallel CircuitsWhat is the difference between series and parallel circuits? Just have a look of the following video and words description about series circuits and parallel circuits to get the basics and differences of them.Series vs Parallel CircuitsSeries connection is one of the basic ways to connect circuit elements. The circuit formed by connecting various electrical parts in series. In the series circuit, the current through each part is equal.Parallel connection is another connection method between electrical components. Components connected in parallel are connected in multiple paths so that the current can split up, and the same voltage is applied to each component.Ⅱ Series Circuits and Parallel Circuits Calculation👉 Resistors in Series and Parallel Circuits2.1 ResistorsResistors in SeriesAs shown in the figure, n resistors connect in series. Now connect the power supply to both ends of this series circuit. According to Kirchhoff’s current law, the current given from the power supply is equal to the current through each resistor, so .According to Ohm’s law, the voltage across the k-th resistor is equal to the current through multiplied by its resistance .According to Kirchhoff’s voltage law, the voltage across the power supply is equal to the algebraic sum of the voltage across all resistors.Therefore, the equivalent resistance Req of n resistors in series is .According to Ohm’s law, the voltage across the power source is equal to the given current times the equivalent resistance .Pay attention to the voltage shared by the resistors of the series circuit is proportional.Conductance G is the reciprocal of resistance R, so the equivalent conductance of n resistors in series is Among them, Gn is the conductance of the n-th resistor.For the simple case of two resistors in series, the equivalent conductance is .Resistors in ParallelWhen linear resistors connect in parallel, the conductance (the reciprocal of resistance) is equal to the sum of the conductances of the parallel resistors, which is called the equivalent conductance, and the reciprocal is called the equivalent resistance. For example, the resistances of R1, R2, and R3, their conductances are G1, G2, and G3, respectively. The total resistance R and total conductance G of the parallel circuit are calculated according to the formula .Note: Calculate the total series and parallel resistance of a circuit using Apogeeweb's Parallel and Series Resistor Calculator. 👉 Capacitors in Series and Parallel Circuits2.2 CapacitorsCapacitors in SeriesAs shown in the figure, n capacitors are connected in series. From the definition of capacitor, it can be obtained that the current passing through the k-th capacitor is equal to its capacitance multiplied by the voltage change rate across it:According to Kirchhoff’s current law, the current i given from the power source (ac or dc) is equal to the current passing through each capacitor, so According to Kirchhoff’s voltage law, the voltage across the power supply is equal to the algebraic sum of the voltage across all capacitors:The voltage change rate of the power supply end is .Therefore, the equivalent capacitance Ceq of n capacitors in series is Each capacitor has a “voltage rating” set by its manufacturer. Assuming that the working voltage exceeds the voltage rating of the capacitor, it may cause capacitor failure. In order to avoid it, several similar capacitors can be connected in series to make the algebraic sum of the voltage rating greater than the operating voltage. However, this will also reduce the equivalent capacitance of the circuit.Capacitors in ParallelAs shown in the figure, n capacitors are connected in parallel. From the definition of capacitor, it can be obtained that the current ik through the k-th capacitor is equal to its capacitance Ck multiplied by the voltage change rate across it:According to Kirchhoff’s voltage law, the voltage across the power supply is equal to the voltage across each capacitor:According to Kirchhoff’s current law, the current given from the power source (dc or ac) is equal to the algebraic sum of the current through each capacitor: Therefore, the equivalent capacitance Ceq of n capacitors in parallel is .Note: Calculate the total series and parallel capacitance of a circuit using Apogeeweb's Series and Parallel Capacitance Calculator. 👉 Inductors in Series and Parallel Circuits2.3 InductorInductor in SeriesAs shown in the figure, n inductors are connected in series. According to the method described above, the equivalent inductance can be calculated as .Among them, Ln is the inductance of the n-th inductor.The magnetic field generated by the inductor will be coupled with the winding coil of the adjacent inductor. So it is difficult to avoid the mutual influence of the adjacent inductors. The mutual inductance M of physical quantities can give a measure of this influence.A series circuit composed of two inductors L1 and L2, and the mutual inductance Ms.1) Assuming that the magnetic fields or fluxes generated by two inductors are in the same direction, the equivalent mutual inductance Leq is expressed by the equation: 2) Assuming that the magnetic fields or fluxes generated by two inductors are in opposite directions, Leq is expressed by the equation:For a parallel circuit with three or more inductors, it is necessary to consider the self-inductance of each inductor and the mutual inductance among the inductors, which makes the calculation more complicated. The equivalent inductance is the algebraic sum of all self-inductance and mutual inductance.For example, a series circuit composed of three inductors will involve three self-inductances and six mutual inductances. The self-inductances of the three inductors are M11, M22, and M33, and the mutual inductances are M12, M13, M21, M23, M31, and M32.Equivalent inductance is .Since the mutual inductance between any two inductors is equal to each other, the latter two sets of mutual inductance can be combined:Inductors in ParallelN ideal inductors without mutual inductance are connected in parallel. Similar to the method described above, the equivalent inductance Leq can be calculated as .Among them, Li is the inductance of the i-th inductor.The above equation describes an ideal case where n inductors are connected in parallel without mutual inductance.A parallel circuit composed of two inductors with inductances L1 and L2 and mutual inductance M:1) Assuming that the magnetic fields or fluxes generated by two inductors are in the same direction, the equivalent mutual inductance Leq is expressed by the equation: 2) Assuming that the magnetic fields or fluxes generated by two inductors are in opposite directions, Leq is expressed by the equation:For a parallel circuit with three or more inductors, it is necessary to consider the self-inductance of each inductor and the mutual inductance among the inductors, which makes the calculation more complicated. 👉 Switch in Series and Parallel Circuits2.4 SwitchSwitch in SeriesTwo or more switches are connected in series to form an or gate circuit. Assuming a power supply is connected to both ends of the circuit, current will only flow when all switches are closed.Switch in ParallelTwo or more switches are connected in parallel to form an or gate circuit. Assuming that a power supply is connected to both ends of this circuit, even though any one of the switches is closed, current will flow. 👉 Power Supply in Series and Parallel Circuits2.5 Power SupplyPower Supply in SeriesFor example, assuming that several cells in the battery pack are connected in series to form a power source, the voltage across the power source is the algebraic sum of the voltages across all cells.Power Supply in ParallelFor example, assuming that a battery pack uses several single batteries with the same voltage connected in parallel as a power source, the voltage across the power source is equal to the voltage across the single battery.Note: Get more info from Switching Power Supply Circuit Diagram with Explanation. 2.6 Series and Parallel Circuits RulesHow to judge whether the electrical circuits are connected in series or in parallel? Series and parallel are the two most basic forms of circuit connection, and there are certain differences between them. So get to know their basic characteristics well according to the following specific methods.(1) Visual CheckLook at the connection form of electrical parts in the circuit. The one by one in sequence is series; the one paralleled between two points of the circuit is parallel.(2) Current FlowWhen the current flowing from the positive pole of the power supply to each element in turn shows that the circuit is in series; when the current flows to two branches and get together at a certain place finally, it indicates that the circuit is in parallel.(3) Removing ComponentsRemove one electrical part at will to see whether other electrical components are working normally. If the circuit can continue to work, then the connection relationship of this circuit is in parallel, otherwise, it is in series. Ⅲ Six Circuit Design Software Tools Introduction3.1 Protel PCB Design PlatformProtel PCB is a CAD software for the circuit industry launched by Protel Systems Pty Ltd in 1985, and has rebranded to Altium Designer. It has many advantages compared with many EDA software for circuit designers. Almost all circuit companies use it. The early Protel PCB was mainly used as a printed board automatic wiring tool. It ran in DOS and had fewer hardware requirements. It can run under the 1M memory of a 286 machine without a hard disk. However, it’s less functional, only electrical schematic drawing and printed board design functions, and the PCB layout rate of automatic wiring is also low.It is a professional circuit board drawing tool. It includes electrical schematic drawing, analog circuit and digital circuit mixed signal simulation, multilayer PCB design, programmable logic device design, chart generation, circuit table generation, and supports macro operations, etc. And it has a client/server architecture. PROTEL is also compatible with some other design software file formats, such as ORCAD, PSPICE, EXCEL, etc. Using automatic routing of multi-layer can achieve 100% layout rate of high-density PCBs.3.2 Altium DesignerAltium Designer is one of the most popular of the high end PCB design software packages on the market today. It provides a single, unified application that incorporates all the technologies and capabilities necessary for complete electronic products, which mainly runs on the Windows operating system. This software provides designers with brand-new design solutions through the perfect integration of schematic design, circuit simulation, PCB drawing editing, topology logic automatic routing, signal integrity analysis and design output, etc. When using this software, the quality and efficiency of circuit design can be greatly improved.Fully inheriting the functions and advantages of the previous series of versions of Protel 99SE and Protel DXP, Altium Designer has many improvements and many high-end features. The platform broadens the traditional interface of board-level design and fully integrates FPGA design functions and SOPC design implementation functions, allowing engineers to integrate FPGA in system design with PCB design and embedded design. With these advantages, Altium Designer requires higher computer system performance than the previous version. 3.3 Quartus IIThe Altera Quartus II design software is a multiplatform design environment that easily adapts to your specific needs in all phases of FPGA and CPLD design. In other words, Quartus II software delivers the highest productivity and performance for Altera FPGAs, CPLDs, and HardCopy ASICs. It is a comprehensive CPLD/FPGA development software, and supports schematics, VHDL, VerilogHDL and AHDL (Altera Hardware supports Description Language) and other design input forms. Quartus II embedded with its own synthesizer and simulator, can complete the process of design input to the hardware configuration. It can run in Windows, Linux and Unix. Use Tcl scripts to complete the design process, and it also provides a complete user graphical interface design method. Quartus II has the characteristics of fast running speed, unified interface, centralized function, easy to learn and easy to use.Quartus II provides a fully integrated development which independent of circuit structure, with all the features of digital logic design, including:1. You can use the schematic diagram, structural block diagram, VerilogHDL, AHDL and VHDL to complete the circuit description, and save it as a design entity file.2. Chip (circuit) plane layout wiring editing3. With LogicLock region, users can build and optimize the system, and add subsequent modules that have little or no impact on the performance of the original system.4. Powerful logic synthesis tool5. Complete circuit function simulation and sequential logic simulation6. Timing analysis and critical path delay analysis7. Signaltap ii logic analyzer can be used for embedded logic analysis.8. Support the addition and creation of software source files, and link them to generate programming files.9. Use the combined compilation method to complete the overall design process at one time.10. Automatically locate compilation errors.11. Efficient period programming and verification12. Read into standard EDIF, VHDL and Verilog netlist files.13. It can generate VHDL and Verilog netlist files used by third-party EDA software.3.4 Electronics Workbench (EWB)EWB is is a mixed-mode SPICE-based electronics design and simulation tool, launched by Interactive Image Technology Co., Ltd. in the early 1990s. It is used for mixed simulation of analog circuits and digital circuits. With this powerful software, you can directly see the output of various circuits on the screen.Compared with other EDA software, EWB is a smaller software, and its function is relatively single. However. its simulation function is very powerful, almost 100% simulation results of real circuits. It provides parts such as multimeters, oscilloscopes, signal generators, frequency sweepers, logic analyzers, digital signal generators, logic converters, etc., and its device library contains many transistor components, integrated circuits and digital gate circuit chips from large companies. In addition, components that are not in the device library can also be imported externally. Among many circuit simulation software, EWB is the easiest to use. Its working interface is very intuitive. The schematic diagram and various tools are in the same window. People who have never touched it can use the software proficiently with a short-time learning. For electronic designers, it is an excellent EDA tool. For many circuits, you can know its results without using a soldering iron. If you want to change components or change parameters, you only need to click the mouse. It can also be used as an auxiliary teaching software for electrical knowledge.3.5 NI MultisimMultisim is a Windows-based simulation tool launched by National Instruments (NI) Co., Ltd.. It is industry standard SPICE simulation and circuit design software for analog, digital, and power electronics in education and research. It includes graphical input of circuit schematics, circuit hardware description language input, and has rich simulation analysis capabilities. Engineers can use it to interactively build circuit schematics and simulate the circuit.With SPICE simulation, designers can quickly capture, simulate and analyze new designs without knowing SPICE deeply, which also makes it more suitable for electronics education. Through Multisim and virtual instrument technology, PCB designers and electronics educators can complete a complete integrated design process from theory to schematic capture and simulation to prototype design and testing.NI Multisim software is an EDA tool software specially used for electronic circuit simulation and design. As a personal desktop electronic design tool running in Windows, NI Multisim is a complete integrated design environment. Its computer simulation and virtual instrument technology can solve the problem of disconnection between theoretical teaching and actual reality experiment. Students can easily reproduce the theoretical knowledge they have learned through computer simulation, and can use virtual instrument technology to create their own instruments. It has an intuitive graphical interface, abundant components, powerful simulation capabilities, abundant testing instruments and complete analysis methods. NI Multisim software is a not bad teaching tool.3.6 Allegro PCBAllegro PCB is an advanced PCB design routing tool introduced by Cadence. It provides a good and interactive working interface, and powerful and complete functions. Provide the most perfect solution for the current high-speed, high-density, multi-layer complex PCB design and wiring, with the combination of its front-end products Cadence, OrCAD, and Capture. Allegro has a complete constraint setting. Users only need to set the wiring rules as required. The wiring design requirements can be met without violating DRC, thus saving tedious manual inspection time and improving work efficiency. It can also define parameters such as minimum line width or line length to meet the various requirements of today's high-speed circuit board wiring. Allegro PCB enables you to do high-speed design, RF antenna, flex-circuitry, and design for manufacturing (DFM) technology.For the drawing and modification functions of copper foil that the industry attaches great importance to, Allegro provides a simple and convenient inner layer division function, as well as the ability to review the inner layer of the positive and negative film. For copper paving, it can also be divided into dynamic copper or static copper, which can be used for different applications. Dynamic copper parameters can be divided into different levels of settings for all copper, single copper or single object, so as to meet the requirements of different connection effects or spacing values to match the special settings due to design requirements. Ⅳ Frequently Asked Questions about Series and Parallel Circuits1. What is the difference between parallel and series circuits?In a parallel circuit, the voltage across each of the components is the same, and the total current is the sum of the currents flowing through each component. ... In a series circuit, every device must function for the circuit to be complete. If one bulb burns out in a series circuit, the entire circuit is broken. 2. What are the rules for series and parallel circuits?Rules regarding Series and Parallel CircuitsVoltage drops add to equal total voltage.All components share the same (equal) current.Resistances add to equal total resistance. 3. What are the similarities and differences between series and parallel circuits?Series circuits are designed so that the current through each component is the same, whereas parallel circuits are designed so that the voltage through each component is the same. 4. Why is resistance different in series and parallel?In a series circuit, the output current of the first resistor flows into the input of the second resistor; therefore, the current is the same in each resistor. In a parallel circuit, all of the resistor leads on one side of the resistors are connected together and all the leads on the other side are connected together. 5. Which software is best for circuit design?Based on Proto-Electronics client preferences, we have drawn up the top 10 best electronics CAD software programmes.EagleAltiumProteusKiCadCadence OrCAD PCB DesignerDesignSparkProtelCadstar
kynix On 2021-01-05
IntroductionAlarm Circuits and Control Circuits are pretty common in daily life. A control circuit is a special type of circuit used to control the operation of a completely separate power circuit. Alarm circuit is a security circuit to reduce life loss and poverty under the excepted prevailing conditions. Both are quite famous and you probably could have seen plenty of different versions of them. Here, we will introduce several available home/office hobby circuits for smoking alarm, temperature controlling and timing, with their design principles, and component selection. They will provide more convenience for your daily life.A Simple Guide to Electronic Components in CircuitsCatalogIntroductionⅠ Indoor Monitoring Circuit DesignⅡ Smoke Alarm Circuit DesignⅢ Temperature Controlled Circuit Using NE555Ⅳ Temperature Sensor Circuit for Temp MeasuringⅤ Water Tank Temperature Controlled ProjectⅥ Cyclic Timing Circuit DiagramⅦ Indoor Overvoltage Protection Circuit DesignⅧ Temperature Fan Controller DiagramⅨ Water Boiling Alarm Circuit DesignⅩ FAQEvery alarm circuit and control circuit is composed of a number of basic components connected together to achieve the desired performance. The following lists some common and simple alarm and control circuits diagrams to share different ideas for protecting your home/office and making your life more easier.Ⅰ Indoor Monitoring Circuit DesignThe monitor can detect infrared rays emitted by the human body, and when a person enters the monitoring area, it can sound for alarm. It is suitable for homes, offices, warehouses, laboratories and other important occasions.👍 Circuit Working ModelFigure 1. Infrared Detection Alarm CircuitThe device consists of an infrared sensor, a signal amplifier circuit, a voltage comparator, a delay circuit and an audio alarm circuit. When the sensor IC1 detects the infrared signal radiated by the human body in front, it outputs a weak electrical signal from the pin②. It is amplified by the first-stage amplifying circuit formed by the transistor VT1, and then input to the operational amplifier IC2 through C2 with high gain and low-noise amplification. IC3 acts as a voltage comparator. Its pin⑤ reference voltage is provided by R10 and VD1. When the signal voltage output by IC2 pin① pass to the IC3 pin⑥, the voltages of the two input terminals are compared. At this time, IC3 pin⑦ changes from the high level to the low level. IC4 is an alarm delay circuit, formed by R14 and C6. Its continuous time is about 1 minute.When IC3 pin⑦ becomes low level, C6 discharges through VD2, IC4 pin② becomes low level, which is compared with IC4 pin③ reference voltage. When it is lower than its reference voltage, IC4 pin① changes to high level, VT2 is turned on, and the buzzer BL is powered on and emits an alarm sound. After the infrared signal of the humans disappears, IC3 pin⑦ outputs to high level, and VD2 is cut off at this time. Since the voltage at both ends of C6 cannot change suddenly, charge C6 slowly through R14. When the voltage at both ends of C6 is higher than its reference voltages, IC4 pin① becomes low level for about 1 minute. That is, the alarm time lasts for 1 minute.The power-on delay circuit is composed of VT3, R20, and C8. It is mainly to prevent alarming immediately when powering on, so that the user has enough time to leave the monitoring site, and at the same time can prevent a false alarm occurred during a power cut. The device uses 9-12V DC power supply, with T step-down, full-bridge rectification, and C10 filtering. The detection circuit uses IC5 for power supply, and automatic non-stop conversion with AC and DC. 👉 Components SelectionIC1 adopts imported device Q74, the wavelength is 9~10um. IC2 uses op-amp LM358, which has high gain and low power consumption. IC3 and IC4 are dual voltage comparators LM393 with low power consumption and low offset voltage. Among them, C2 and C5 must use tantalum capacitors with small drain electrodes, otherwise the debugging will be affected. R12 is the key element to adjust sensitivity, and linear high-precision sealed type should be selected. Other components can be selected as shown in the circuit diagram. 👉 DIY and AdjustmentWhen making, a Fresnel lens is installed in front of the IC1 sensor. Since the frequency range of the human body is 0.1~10Hz, it is necessary to use the Fresnel lens to multiply the frequency of the human body. After installation finished, connect the power supply for debugging. Let a person walk about 7-10m in front of the detector, adjust R12 in the circuit, and make the buzzer alarm. As long as the other parts are of good quality and welded correctly, they can work normally without debugging. The static working current of this machine is about 10mA. It will enter the waiting state about 1 minute after the power is turned on. As long as someone enters the monitoring area, it will alarm, and stops in 1 minute. In addition, if the buzzer is changed to a relay to drive other devices, it will be used for other controls. Ⅱ Smoke Alarm Circuit DesignThis smoke alarmer can be used in family rooms or various places where smoking is forbidden (such as hospitals, conference rooms, etc.). When someone smokes, the no-smoking warning device will emit a warning sound of "No Smoking!" to remind the smoker to stop smoking consciously.👍 Circuit Working ModelFigure 2. Smoke Alarm CircuitThe no-smoking warning circuit is composed of a smoke detector, a monostable trigger, a voice generator and a power amplifier circuit. The smoke detector consists of potentiometer RP1, resistor R1 and gas sensor. The monostable trigger has time-base integrated circuit IC1, resistor R2, capacitor C1, and potentiometer RP2. The voice generator circuit is composed of voice integrated circuit IC2, resistors R3-R5, capacitor C2 and Zener diode VS. The audio power amplifier circuit includes transistor V, boost power amplifier module IC3, resistors R6 and R7, capacitors C3 and C4, and speaker BL.When the gas sensor doesn’t detect smoke, the resistance value between A and B is relatively large. IC1 pin2 is high level (higher than 2VCC/3), pin3 outputs low level, while voice generator circuit and the audio power amplifier circuit does not work. When someone smokes and the gas sensor detects the smoke, the resistance value between the A and B becomes smaller, causing the voltage of IC1 pin2 to drop. When the voltage of this pin drops to VCC/3, IC1 pin3 changes from low level to high level. Pass through current limiter R3, filter C2 and Zener diode VS, the high level will generate 4.2V DC voltage, which is supplied to voice IC2 and crystal arm. After IC2 energizes and works, it outputs a voice electrical signal. After the signal is amplified by V and IC3, it makes BL to emit a voice warning sound of "No Smoking!" 👉 Components SelectionRl~R7 selects 1/4W carbon film resistor or metal film resistor for use. RP1 and RP2 can choose small linear potentiometer or variable resistor. C1, C2 and C4 all use aluminum electrolytic capacitors with a withstand voltage of 16V; C3 uses monolithic capacitors. VS selects the silicon Zener diode of 1/2W, 4.2V for use. V uses S9013 or C8050 silicon NPN transistors. IC1 uses the NE555 timer IC; IC2 uses the voice integrated circuit; lC3 uses the WVH68 boost power amplifier thick-mode IC. BL selects 8Ω, 1~3W electrodynamic speakers. The gas sensor is MQK-2 type sensor. 👉 DIY and AdjustmentThis no-smoking warning device can be used as a smoke alarm to detect fires or harmful gases, and combustible gases. Adjusting the RP1 resistance can change the heating current of the gas sensor (usually about 130mA). And adjusting the RP2 resistance can change the sensitivity of the monostable trigger circuit. Ⅲ Temperature Controlled Circuit Using NE555This circuit is an automatic temperature controller composed of a 555 timer IC and a few peripheral components. Because the voltage at each point in the circuit comes from the same DC power supply, it does not need a high-performance regulated one. Using the capacitor step-down method can work reliably. The circuit components are low in price, small in size, and easy to self-made under amateur conditions. The automatic temperature controller made by this circuit can be used for electric heating control in industrial production and household use, with good effect.👍 Circuit Working ModelFigure 3. 555 Timer Based Circuit for Temperature ControlWhen the temperature is low, the resistance of the thermistor Rt with a negative temperature coefficient is large, the potential of pin2 of the 555 timer IC is lower than 1/3 of the voltage of Ec (about 4V), and its pin3 output high level. At this time, V conducts, the heater RL is heating, and the timing cycle starts. When the temperature of the thermistor Rt is higher than the set value and the timing cycle has not been completed, the heater RL will cut off after the timing cycle stops. When the Rt temperature drops below the set value, V will conduct again and turn on the heater RL for heating. In this way, automatic temperature control can be achieved. 👉 Components SelectionIn this circuit, the thermistor Rt can be a negative temperature coefficient type MF12 or MF53, or other types of negative temperature coefficient thermistors with different resistance values, as long as Rt+VR1= 2R4 is satisfied under the temperature condition to be controlled. A larger potentiometer VR1 can have a larger adjustment range, but its sensitivity will decrease. The bidirectional thyristor V can also be selected according to the size of the load current. There are no special requirements for other components. Choose according to the parameters given in the circuit diagram. 👉 DIY and AdjustmentThe whole circuit can be installed on PCB. Generally, debugging is not required. The time interval is 1... .1R2×C3, which should be smaller than the thermal time constant of the heating system, but not too small, otherwise it will cause excessive radio frequency interference due to the thyristor V turns on or off rapidly. After installation and debugging, it can be put into a small plastic box, and the thermistor Rt can be led to the required place. Ⅳ Temperature Sensor Circuit for Temp MeasuringThis circuit is a thermometer made by AD590 special integrated temperature sensor, which has the characteristics of simple structure, reliable use and high precision.👍 Circuit Working ModelFigure 4. Digital Thermometer CircuitAfter the 100V AC voltage passes through the transformer T1, the rectifier bridge stack UR and the capacitor C1, the DC voltage is obtained, and then the adjustable voltage regulator circuit μA723C provides a stable working voltage for the temperature sensor AD590. AD590 is a new type of current output temperature sensor, composed of multiple transistors and resistors with the same parameters. When a specific DC working voltage is applied to both ends of the sensor, if the sensor temperature is 1 degree Celsius, the output current of the sensor changes by 1 μA. The changing current of the sensor is converted into a voltage signal through the resistor R5 and the variable resistor RP2, and then output to the digital meter, which displays the temperature change. 👉 Components SelectionThe IC selects AD590-series temperature sensor. There are no special requirements for other components of this circuit, and can be selected according to the parameters given in the circuit diagram. 👉 DIY and AdjustmentBy adjusting the value of resistor R5 and variable resistor RP2, the sensitivity of the circuit output can be improved. Ⅴ Water Tank Temperature Controlled ProjectAn automatic fish tank water temperature controller uses a negative temperature coefficient thermistor as a temperature sensor to automatically heat the fish tank through heating gas. The transient time of this circuit is small, which is beneficial to the accuracy of temperature control. And it is suitable for various sizes of fish tanks.👍 Circuit Working ModelFigure 5. Automatic Control of Fishbowl Water TemperatureAfter being rectified by diodes VD2~VD5 and filtered by capacitor C2, a voltage of about 12V is provided to the control part of the circuit. 555 timer is connected as a monostable flip-flop, the transient state is 11s. Set the control temperature to 25ºC, adjust the potentiometer RP, to get RP + Rt = 2R1 ( Rt is the thermistor with negative temperature coefficient). When the temperature is lower than 25ºC, the Rt resistance value increases, and the pin2 of the 555 timer is low level, then the pin3 output changes from low level to high level. The relay K is turned on, and its contact is closed. The heating tube starts to heat until the temperature returns to 25ºC, the Rt resistance value becomes smaller, the pin2 of the 555 timer is at high level, and the pin3 outputs low level. The relay K loses power, its contact is open, and the heating stops. 👉 Components SelectionIC uses NE555, NA555, SL555 and other 555 timer ICs; VD1 uses IN4148 silicon switching diodes; LED uses common light-emitting diodes; VD2~VD5 uses IN4001 silicon rectifier diodes; Rt uses 470Ω MF51-type negative temperature coefficient thermistors at room temperature; RP uses WSW organic solid trimming potentiometer; R1and R2 uses RXT-1/8W carbon film resistors; C1 and C3 uses CD11-16V electrolytic capacitors; C2 uses CT1 ceramic dielectric capacitors; K uses 12V JZC-22F electromagnetic relay. 👉 DIY and AdjustmentThe temperature sensor probe connects the thermistor Rt with wires, and then seals the solder joint with epoxy glue, to avoid water erosion. As long as the circuit is correct in the DIY process, this circuit is easy to operate. If the component performance is good, it can be used without debugging after installation. Ⅵ Cyclic Timing Circuit DiagramThe circuit can set the cycle time of the equipment and each time it works, allowing the equipment to work continuously according to the set time. This circuit can be applied to control occasions such as timing pumping, timing ventilation, and timing cut off.👍 Circuit Working ModelFgiure 6. Cycle Timing CircuitAfter the circuit is stepped down through the capacitor C2 and the bleeder resistor R3, and then rectified by the bridge stack IC2, and stabilized by VD2, a DC voltage of about 12V is obtained to supply power to IC1 and other circuits. IC1 is a 14-bit binary counter/frequency divider integrated circuit. A clock oscillator with a certain frequency is formed by the internal circuits of R1, R2, C1 and IC1 to provide clock pulses for timing IC1. When the circuit is powered on, it first enters the working gap waiting time of the device. IC1 internally realizes the delay by counting and dividing the clock pulse. When the timing is up (according to the parameters in the figure, about 3 hours), the Q14 terminal of IC1 outputs high level, making the transistor V conducts. The relay KA gets to work, and drives the controlled equipment to start working. At this time, IC1 starts to count the working time of the device again. When the timing expires (according to the parameters in the figure, about 20 minutes), the Q14 terminal outputs low level. So that V is cut off and the device stops working. And meanwhile, IC1 automatically resets and starts the next timing. So that the device can perform timing cycle according to requirements. In the figure, VL is a working indicator. 👉 Components SelectionIntegrated circuit IC1 chooses 14-bit binary counter/frequency divider CD4066, or CC4066 or other digital circuit integrated blocks with the same function. IC2 selects a 1A, 50V bridge stack, or can be connected with four 1N4007 diodes. Transistor V uses NPN-type transistor 8050, and other transistors such as 9013 or 3DG12 can also be used. VD1 selects rectifier diode 1N4007; VD1 selects 1W, 12V silicon regulator tube, such as 1N4742; VD3 ~VD5 use switching diodes 1N4148; VL selects ordinary light-emitting diodes. Resistors R1, R2, R4, R6 and R7 use 1/4W metal film resistors; R3 and R5 use 1/2W carbon film resistors. C1 selects polyester or monolithic capacitors; C2 selects polypropylene capacitors with a withstand voltage of 450V and above; C3 selects aluminum electrolytic capacitors with a withstand voltage of 16V. Relay KA chooses a miniature relay with a coil voltage of 12V, and the contacts capacity is determined according to the power of the controlled device. 👉 DIY and AdjustmentAfter the circuit is installed, it can work normally without debugging. When you need to adjust the control time, you can adjust the parameters of R1, and C1. Also you can change the position of the IC1 output control terminal (Q4 ~Q14). Ⅶ Indoor Overvoltage Protection Circuit DesignBecause the instability of the mains, the household appliances often affected, their service life may reduce. In serious cases, it is easy to burn out due to voltage surge. The circuit described in this example can solve this problem well.👍 Circuit Working ModelFigure 7. Overvoltage Protection Circuit for AppliancesThe mains supply provides a stable 12V working voltage for the switch integrated circuit via C1, VD1, and DW1. VD3, R2 and RP1 form a voltage divider sampling circuit. When the mains voltage is normal, DW2 cannot be turned on, the working voltage of TWH8778 pin⑤ is lower than 1.6V. The relay J does not pull in, and the mains supplies the CZ socket through the J-1 normally closed contact. When the mains voltage is high than the normal setting, DW2 breaks down, the potential of TWH8778 pin⑤ rises to 1.6V, causing the IC to flip, pin ③ outputs high level. At this time, the relay is pulled in, and the electrical power supply is immediately cut off, avoiding the overvoltage affects electrical appliances. 👉 Components SelectionC1 uses 0.47µ/400V electrolytic capacitor, relay J uses 6V DC contactor; RP uses ordinary trimming potentiometer, chip IC can be TWH8778-type electronic switch or TWH8752-type electronic switch. 👉 DIY and AdjustmentAfter the device is welded correctly, connect the mains power to the input end of the voltage regulator, cooperate with the voltage regulator and carefully adjust RP1, so that the relay J is closed when the voltage is 250V, and then the circuit is connected to the mains power grid. Ⅷ Temperature Fan Controller DiagramThis is an automatic fan temperature controlled governor, which can automatically adjust the speed according to the temperature change. The circuit can be adjusted, so it can be used for the control of other electrical equipment.👍 Circuit Working ModelFigure 8. Automatic Temperature Control and Speed Regulation in Fan CircuitThe IC in the picture is a 555 timer IC, which forms a multivibrator with components of R2, R3 and C2. It can send out a rectangular wave signal with an adjustable duty cycle. When the temperature changes, the resistance value of the thermistor changes, so the duty cycle of the square wave output by the multivibrator changes. Adjusting the conduction angle of the bidirectional thyristor VT changes the voltage across the fan electrodes, which automatically adjusts the speed of the electric fan. 👉 Components SelectionThe integrated circuit IC selects NE555 timer, and models such as LM555 and TLC555 can also be used. VT is a bidirectional thyristor, its withstand voltage should be above 400V, and the rated current should be reasonably selected according to the capacity of the electric fan to be controlled. Resistor R1~R5 can choose ordinary 1/8 or 1/4W carbon film resistors; Rt is a negative temperature coefficient thermistor, and can choose a thermistor with a resistance of about 10KΩ at room temperature. Capacitor C1 uses ordinary aluminum electrolytic capacitors; Capacitors C2 and C3 are polyester capacitors. VD is a Zener diode with a steady voltage of 9.1V. 👉 DIY and AdjustmentYou can make your own PCB, or use a universal one. After the circuit is installed, the temperature of the thermistor Rt can be artificially changed to observe the speed of the fan motor. If the temperature control effect is not ideal, the resistance value or temperature change range of the thermistor can be adjusted appropriately. Ⅸ Water Boiling Alarm Circuit DesignOnce the water boils in the kitchen, if it is not turned gas off in time, the boiling water will overflow and extinguish the flame. The gas may spill, which is very unsafe. This problem can be solved by using the water alarm.👍 Circuit Working ModelFigure 9. Boiling Water Alarm CircuitThis circuit uses thermistor as the temperature sensing element. When the water temperature rises, the resistance of the thermistor decreases and the potential at point A increases. When the potential at point A is higher than the conversion voltage of the IC-1 inverter, the IC -1 will output low level, IC-2 will output high level. Making the audio oscillator composed of IC-3 and IC-4 work, and the piezoelectric ceramic sheet makes sound. When IC-2 outputs low level, the audio oscillator doesn’t work, and the piezoelectric ceramic chip is silent. 👉 Components SelectionIC uses C066 two input terminal four NAND gate, working voltage 3V~18V, power supply is 3V~6V; RT thermistor selection resistance value is about 1kΩ; piezoelectric ceramic chip diameter is 27mm; resistor selection is ordinary 1/8 or 1/4W metal film resistors. 👉 DIY and AdjustmentFind two starter shells of waste fluorescent lamps, use iron sheet as a clip, close the tops of the two starters, and fasten them with screws. One of the starters can be set on the mouth of the kettle to obtain the temperature of the water. The two pins of the thermistor are welded on the cover of the other starter and put into the shell. Note that the thermistor must be close to the inner shell wall to facilitate heat transfer. Solder the outer lead of the thermistor and the temperature sensor. After all the components are welded and checked, you can turn on the power for debugging. Put the temperature sensor on the mouth of the kettle, and adjust the RP when the water boils to make the piezoelectric ceramic sheet sound. Repeat it several times before this circuit can be used normally. If you want to change the sound frequency, you can change the C2 capacity. If you feel that the sound is light, you can connect an external transistor to the IC-4 output terminal to amplify the sound. Ⅹ FAQ1. How do you make a security alarm circuit?The cathode of the photodiode is connected to the supply while the anode is connected to a 10KΩ resistor. Another end of the resistor is connected to the ground. The anode terminal of the photodiode is also connected to pin 5 of the LM358 op-amp, which is the non-inverting terminal. 2. What is the technique of alarm circuits?In a closed-circuit system, the electric circuit is closed when the door is shut. This means that as long as the door is closed, electricity can flow from one end of the circuit to the other. But if somebody opens the door, the circuit is opened, and electricity can't flow. This triggers an alarm. 3. What is a security alarm circuit?This circuit will help you to guard your precious documents as well as jewelry from intruders or theft. All you need is just to place this circuit in front of the locker or below the mat so when any unknown person comes and walks over the switch, the circuit will trigger and the sound of an alarm comes. 4. What type of circuits are security alarms made of?The simplest type of contact-operated security circuit consists of an alarm bell (or a buzzer or electronic 'siren sound' generator, etc.), wired in series with a normally-open (n.o.) close-to-operate switch; the combination being wired across a suitable battery supply, as shown in the basic 'door-bell' alarm circuit ... 5. What are the three basic parts of an alarm system?The main components of an alarm system would be a sensor, a camera, a motion detector, a buzzer a flash light and batteries. It is a component that is usually used to detect noise or movement. Sensors are usually connected to the circuit.
kynix On 2020-12-24
IntroductionDefinition: A ceramic capacitor is a capacitor that has a ceramic dielectric as its dielectric material. Multi-layer ceramic capacitors and ceramic disc capacitors are the two most common types. The dielectric in a ceramic capacitor is ceramic. Ceramics, a well-known insulator, is one of the first materials used in the manufacture of capacitors. Ceramic capacitors come in a variety of geometric forms, some of which have been phased out due to size, parasitic effects, or electrical characteristics, such as ceramic tubular capacitors and barrier layer capacitors. Multi-layer ceramic capacitor, also known as ceramic multi-layer chip capacitor (MLCC), and ceramic disc capacitor are the two types of ceramic capacitors most widely used in modern electronics. Typical Multilayer Ceramic Capacitor With a production volume of about 1000 billion devices per year, MLCCs are the most widely used capacitors. Due to their small size, they are commonly used and manufactured using SMD (surface-mounted) technology. Ceramic capacitors are usually made with very small capacitance levels, ranging from 1nF to 1F, with a maximum capacitance of 100F. Ceramic capacitors are thin, and their maximum rated voltage is low. Since they lack polarity, they can be safely linked to AC electricity. Due to low parasitic effects including resistance and inductance, ceramic capacitors have excellent frequency response. Ceramic capacitors have the following advantages over other capacitors: small size, large capacity, good heat resistance, mass production suitability, and low price.CatalogIntroductionCatalogⅠThe Origin of Ceramic CapacitorsⅡ Classification of Ceramic Capacitors 2.1 Semiconductor Ceramic Capacitors 2.2 High Voltage Ceramic CapacitorsⅢ Characteristics 3.1 Precision and Tolerance 3.2 Size Advantages 3.3 High Voltage and High PowerⅣ Ceramic Dielectric TypesⅤ Construction and Properties of Ceramic Capacitors 5.1 Ceramic Disc Capacitors 5.2 Multi-layer Ceramic Capacitor (MLCC) Ⅵ Advantages and Disadvantages 6.1 Advantages 6.2 DisadvantagesⅦ Applications for Ceramic CapacitorsⅧ How to read ceramic capacitor value?Ⅸ How to Test Ceramic Disc CapacitorⅩ FAQⅠThe Origin of Ceramic CapacitorsLombardi from Italy invented ceramic dielectric capacitors in 1900. It was discovered in the late 1930s that by adding titanate to ceramics, the dielectric constant can be doubled, resulting in cheaper ceramic dielectric capacitors. Ceramic capacitors were first used in military electronic equipment around 1940, following the discovery of the insulation properties of BaTiO3 (Barium titanate), the primary raw material for today's ceramic capacitors. Around 1960, ceramic laminate capacitors became commercially available. It had become an essential part of electronic devices by 1970, thanks to the rapid growth of hybrid IC, computers, and portable electronic devices. Ceramic dielectric capacitors currently account for approximately 70% of the overall capacitor market. Historic Ceramic CapacitorsⅡ Classification of Ceramic Capacitors2.1 Semiconductor Ceramic Capacitors(1)Surface Layer Ceramic CapacitorThe miniaturization of capacitors, that is, the capacitor obtains the largest possible capacity in the smallest possible volume, which is one of the development trends of capacitors. For the separation of capacitor components, there are two basic approaches to miniaturization: ①Make the dielectric constant of the dielectric material as high as possible; ②Make the thickness of the dielectric layer as thin as possible. Among ceramic materials, the dielectric constant of ferroelectric ceramics is very high, but when ferroelectric ceramics are used to manufacture ordinary ferroelectric ceramic capacitors, it is difficult to make the ceramic dielectric very thin. Firstly, due to the low strength of ferroelectric ceramics, it is difficult to carry out actual production operations because it is easy to fracture when it is thin. Secondly, when the ceramic medium is fragile, it is easy to cause various structural defects and the production process will be challenging.(2)Grain Boundary Layer Ceramic CapacitorThe surface of BaTiO3 semiconductor ceramics with sufficiently developed grains is coated with appropriate metal oxides (such as CuO or Cu2O, MnO2, Bi2O3, Tl2O3, etc.), and heat treatment is performed under oxidizing conditions at appropriate temperatures. Then the substance will form a low eutectic solution phase with BaTiO3, rapidly diffuse and penetrate into the ceramic along with the open pores and grain boundaries, forming a thin solid solution insulating layer on the grain boundaries. The resistivity of this thin solid solution insulating layer is very high (up to 1012~1013Ω·cm). Although the ceramic grain interior remains as semiconductor, the entire ceramic body is shown as the dielectric constant of 2×104 to 8×104 dielectric medium. Capacitors made with this kind of porcelain are called boundary layer ceramic capacitors, or BL capacitors for short.2.2 High Voltage Ceramic CapacitorsThe ceramic materials of high-voltage ceramic capacitors are barium titanate-based and strontium titanate-based. Barium titanate-based ceramic materials have the advantages of high dielectric coefficient and good AC withstand voltage characteristics, but also have the shortcomings of capacitance change rate with the increase of medium-temperature and decrease of insulation resistance. The Curie temperature of strontium titanate crystal is -250℃, and it is a cubic perovskite structure at room temperature. It is a para-electric body, and there is no spontaneous polarization phenomenon. Under high voltage, the dielectric coefficient of strontium titanate ceramic material changes little. The dielectric loss tangent value (tgδ) and capacitance change rate are small, which makes it a high-voltage capacitor dielectric. 2.3 Multilayer Ceramic CapacitorsMultilayer ceramic capacitors are the most widely used type of electronic component. They are stacked alternately in parallel with the internal electrode material and ceramic body and fired into a whole, also known as chip monolithic capacitors. It has the characteristic of small size, high specific volume and high precision. It can be mounted on a printed circuit board (PCB) and hybrid integrated circuit (HIC) substrates. It can effectively reduce the volume and weight of electronic information terminal products (especially portable products), and also improve product reliability. Multilayer ceramic capacitors conform to the IT industry's development direction of miniaturization, lightweight, high performance, and multifunction. The outline of the national vision goal for 2010 clearly puts forward that new components such as surface-mounted components should be the development focus of the electronic industry. It is not only simple packaging, good sealing, and can effectively isolate the opposite electrode. MLCC can store charge, block DC, filter merge, distinguish different frequencies and tune the circuit in the electronic circuit. It can partially replace organic film capacitors and electrolytic capacitors in high-frequency switching power supplies, computer network power supplies and mobile communication equipment. What's more, it can greatly improve the filtering performance and anti-interference performance of high-frequency switching power supplies. Ⅲ Characteristics3.1 Precision and ToleranceCeramic capacitors are currently available in two classes: class 1 and class 2. When high stability and low losses are needed, Class 1 ceramic capacitors are used. They are extremely precise, and the capacitance value remains constant regardless of applied voltage, temperature, or frequency. Within a total temperature range of -55 to +125 °C, the capacitance thermal stability of the NP0 series of capacitors is 0.54%. The nominal capacitance value's tolerances can be as poor as 1%. Class 2 capacitors have a large capacitance per volume and are used in less sensitive applications. Their thermal stability in the operating temperature range is usually 15%, and nominal value tolerances are about 20%.3.2 Size AdvantagesMLCC devices outclass other capacitors when high component packing densities are needed, as is the case in most modern printed circuit boards (PCBs). The “0402 multi-layer ceramic capacitor package” measures just 0.4 mm x 0.2 mm to demonstrate this point. There are 500 or more ceramic and metal layers in such a box. As of 2010, the minimum ceramic thickness was on the order of 0.5 microns.3.3 High Voltage and High PowerCeramic capacitors that are physically bigger and can withstand even higher voltages are known as power ceramic capacitors. These are much larger than the ones used on PCBs, and they have specialized terminals for connecting to a high-voltage supply safely. Ceramic capacitors with a power specification of much more than 200 volt-amperes can withstand voltages ranging from 2 kV to 100 kV. Printed circuit boards use smaller MLCCs that are rated for voltages ranging from a few volts to several hundreds of volts, depending on the application.Ⅳ Ceramic Dielectric TypesUnlike other capacitor types such as tantalum capacitors and electrolytic capacitors, ceramic capacitors may use a variety of dielectrics. These various dielectrics give capacitors very different properties, so in addition to deciding on a ceramic capacitor, a second decision about the type of dielectric may be needed. Popular ceramic capacitor dielectrics, such as C0G, NP0, X7R, Y5V, Z5U, and many others, are frequently listed in distributors' lists. However, determining which form is best necessitates a little more study. Ceramic Capacitor Dielectric ClassesSome industry organizations have identified a range of ceramic dielectric application classes to make selecting capacitors with the appropriate dielectric easier. These application groups divide the various ceramic capacitor dielectrics into separate classes based on the anticipated application. International bodies such as the IEC (International Electrotechnical Commission) and the EIA (Electronic Industries Alliance) have standardized these ceramic capacitor classes.Ⅴ Construction and Properties of Ceramic Capacitors5.1 Ceramic Disc CapacitorsCeramic disc capacitors are made by coating a ceramic disc on both sides with silver contacts. These devices can be constructed from several layers to achieve higher capacitances. Ceramic disc capacitors are usually through-hole components that have lost popularity due to their large scale. If capacitance values allow, MLCCs are used instead. Ceramic disc capacitors have capacitance values ranging from 10pF to 100pF and voltage ratings ranging from 16 volts to 15 kV and beyond. 5.2 Multi-layer Ceramic Capacitor (MLCC)MLCCs are made by combining finely ground granules of paraelectric and ferroelectric materials and layering the mixture with metal contacts alternately. Following the layering, the device is heated to a high temperature and the mixture sintered, yielding a ceramic substance with the desired properties. The capacitance of the resulting capacitor is increased by connecting several smaller capacitors in parallel. MLCCs are made up of 500 layers or more, with a minimum layer thickness of 0.5 microns. As technology advances, layer thickness decreases, allowing for higher capacitances in the same volume.Ⅵ Advantages and Disadvantages6.1 AdvantagesThe following are some of the benefits of using a ceramic capacitor:• This capacitor's physical structure is very compact.• It is well suited for the application of AC signals due to its non-polarized nature.• Signal interference suppression, such as radiofrequency suppression and electromagnetic interference suppression, is improved with these capacitors.• This capacitor is reasonably priced, and it can withstand voltages of up to 100 volts.6.2 DisadvantagesThe following are the drawbacks of using these capacitors:• The capacitance value of these capacitors is less than one microfarad.• These components are also responsible for the Microphonic effect in circuits.• It is unable to withstand high voltages. Since it can easily impact the dielectric present in it. As a consequence, there is a breakdown.Ⅶ Applications for Ceramic CapacitorsGiven that MLCCs are the most commonly manufactured capacitor in the electronics industry, it should come as no surprise that they have a wide range of applications. A resonant circuit in transmitter stations is an interesting high-precision, high-power application. High-voltage laser power supplies, power circuit breakers, and induction furnaces all use Class 2 high-power capacitors. Small-form SMD (surface mount) capacitors are commonly used in printed circuit boards, and capacitors the size of a grain of sand are used in high-density applications. They're also used in DC-DC converters, where high frequencies and high levels of electrical noise put a lot of strain on the components. Since ceramic capacitors are non-polarized and come in a wide range of capacitances, voltage ratings, and sizes, they can be used as a general-purpose capacitor. Ceramic disc capacitors, which are used throughout brush DC motors to reduce RF noise, are familiar to many hobbyists, especially in the field of robotics.Ⅷ How to read ceramic capacitor value?Ceramic capacitors normally have three digits for their values, such as 102, 103, and 101, and the values are in Pico farads. The numbering scheme is simple to understand if you note that picofarads, not microfarads, are used.The worth of a ceramic capacitor with three digits – ABC is AB*10^C Pico Farad. The digit 104 means 10*104pF = 100000pF = 100nF = 0.1uF if ABC is 104. The first two digits of the printed code correspond to the first two digits of the capacitor value, while the third digit indicates the number of zeroes that must be applied to convert the capacitor value to Pico Farad. If we calculate in Nano Farad for values ending with 4, then the reading becomes easy like 104 is 100nF. If we calculate in Nano Farad for values ending with 3, then the reading becomes easy like 103 is 10nF.Some ceramic capacitors are polarized, meaning they have both positive and negative terminals. The capacitor can be identified by its tolerance in addition to its capacitance value. There is many tolerance marking schemes in use, with one and two alphabets being the most common. You don't need to recall them unless you're dealing with a precise circuit. We only looked at ceramic capacitors in direct current (DC) circuits with voltages ranging from 12V to near zero in this short article. Hobbyists are familiar with this collection. It is also useful to be familiar with the tolerance marking scheme for professional purposes. Ⅸ How to Test Ceramic Disc CapacitorCeramic disc capacitors are units used in the computer industry to control voltage for various dielectric functions. Ceramic layers aim to dissipate heat generated by high voltage while also protecting the environment — both internal and external — from damage. Volumetric efficiency is inversely proportional to stability and accuracy with these capacitors, making testing difficult.Step 1 Ceramic capacitors must be tested since they will short out if they are exposed to high voltage. Your monitor can blink or go blank if this happens. This issue can be resolved by removing all of the ceramic capacitors. Ceramic capacitors, on the other hand, can be tested if you have the right tools. Step 2To measure a ceramic capacitor, use a wireless multimeter. The capacitor works properly when the voltage is constant. However, you won't be able to accurately calculate it if the ohmmeter's output and digital capacitance don't match the capacitor's voltage, so the second option is preferable. Step 3To locate the short circuit or assess cases where optical capacitance meters fail to produce shortened readings, use an analog insulation tester. In order to obtain a 12-volt output, set the analog meter to 10 Kohm. This phase is needed for the ceramic capacitor to be tested. You may also use both methods to improve measurement precision if you do want to stop removing the capacitor and test it aboard.Related recommendation: How to Test a Start Capacitor? How to Discharge a Capacitor? Ⅹ FAQ1. What is Ceramic Capacitor?A fixed value type of capacitor where the ceramic material within the capacitor acts as a dielectric is the Ceramic Capacitor. This capacitor consists of more alternating layers with ceramic and also a metal layer which acts as an electrode. The composition of this ceramic material in this capacitor tells about the electrical behavior along with its applications. We can define a ceramic capacitor as A fixed-value capacitor where the ceramic material acts as the dielectric. 2. What are the advantages of ceramic capacitors?Following are the advantages of ceramic capacitors:Manufacturing cost is lessHigh-frequency performance is exhibitedThe stability of the capacitor is dependent on the ceramic dielectric 3. What is the capacitance range for a ceramic capacitor?The typical capacitance range for a ceramic capacitor is 10 pF to 0.1 μF. 4. Can I replace all electrolytic capacitors with ceramic ones?If you can find ceramic capacitors of the correct value, you can certainly do this. Ceramic capacitors are more stable, have a longer useful lifetime, have higher voltage ratings and are not polarized. Be prepared to find that there will be a substantial size difference. 5. What are the differences between electrolytic, tantalum and ceramic capacitors?Ceramic capacitors don't have polarity, their terminals can be interchanged. They are suitable for both ac and dc. They don't have any chemical reaction involved in their work. They have a lesser capacity for the same given size. Electrolytic capacitors have polarity (i.e. they have fixed positive and negative terminal), Suitable for dc only. A chemical reaction involves the formation of aluminum oxide on the electrode. ( Consists of aluminum electrodes in a solution of Ammonium borate).Higher capacity. A tantalum electrolytic capacitor, a member of the family of electrolytic capacitors, is a polarized capacitor whose anode electrode (+) is made of tantalum on which a very thin insulating oxide layer is formed, which acts as the dielectric of the capacitor. A solid or liquid electrolyte that covers the surface of the oxide layer serves as the second electrode (cathode) (-) of the capacitor. 6. What is the time constant for the discharge of the capacitors in (figure 1)?figure 1The equivalent resistance:R= 2*1× 10∧3 = 2000 i©=> the time constant: T= R*C = 2000*1× 10∧-6 = 2×10∧-3s = 2ms 7. How do you read a ceramic capacitor value?The first two digits, in this case, the 10 give us the first part of the value. The third digit indicates the number of extra zeros, in this case, 3 extra zeros. So the value is 10 with 3 extra zeros, or 10,000. Ceramic disc capacitor codes are always measured in pico Farads or pF. 8. How can you tell if a ceramic capacitor is bad?Use the multimeter and read the voltage on the capacitor leads. The voltage should read near 9 volts. The voltage will discharge rapidly to 0V because the capacitor is discharging through the multimeter. If the capacitor will not retain that voltage, it is defective and should be replaced. 9. Do ceramic capacitors degrade over time?Among ceramic capacitors, the capacitance, especially of capacitors classified as a high dielectric constant (B/X5R, R/X7R characteristics), decreases over time. ... When the capacitor cools down below the Curie point, aging starts again. 10. How do you tell the positive and negative of a ceramic capacitor?In general, the ceramic capacitor has no positive and negative poles, and the capacity is generally small. It is often used for signal source filtering, and the polarity is only temporary behavior. This is a kind of non-polar electrolytic capacitor, so it is not polar.
kynix On 2020-12-08
Join our mailing list!
Be the first to know about new products, special offers, and more.
Feature Posts
How Resistors Work: From Basic Principles to Advanced Applications2025-07-30
DC Switching Regulators: Principles, Selection, and Applications2025-05-30
FPGA vs CPLD: In-depth Analysis of Architecture, Performance and Application2025-05-07
MOSFET Technology: Essential Guide to Working Principles & Applications2025-05-04
SMD Resistor: Types, Applications, and Selection Guide2025-04-30