FEATURES

8 TO 35 V OPERATION

5.1 V REFERENCE TRIMMED TO ± 1 %

100 Hz TO 500 KHz OSCILLATOR RANGE

SEPARATE OSCILLATOR SYNC TERMINAL

ADJUSTABLE DEADTIME CONTROL

INTERNAL SOFT-START

PULSE-BY-PULSE SHUTDOWN

INPUT UNDERVOLTAGE LOCKOUT WITH HYSTERESIS

LATCHING PWM TO PREVENT MULTIPLE PULSES

DUAL SOURCE/SINK OUTPUT DRIVERS

 

DESCRIPTION

The SG3525A series of pulse width modulator inte- grated circuits are designed to offer improved per- formance and lowered external parts count when used in designing all types of switching power sup- plies. The on-chip + 5.1 V reference is trimmed to ± 1 % and the input common-mode range of the error amplifier includes the reference voltage eliminating external resistors. A sync input to the oscillator al- lows multiple units to be slaved or a single unit to be synchronized to an external system clock. A single resistor between the CT and the discharge terminals provide a wide range of dead time ad- justment. These devices also feature built-in soft-start circuitry with only an external timing capacitor required. A shutdown terminal controls both the soft-start circu- ity and the output stages, providing instantaneous turn off through the PWM latch with pulsed shut- down, as well as soft-start recycle with longer shut- down commands. These functions are also control- led by an undervoltage lockout which keeps the out- puts off and the soft-start capacitor discharged for sub-normal input voltages. This lockout circuitry in- cludes approximately 500 mV of hysteresis for jitter- free operation. Another feature of these PWM cir- cuits is a latch following the comparator. Once a PWM pulses has been terminated for any reason, the outputs will remain off for the duration of the pe- riod. The latch is reset with each clock pulse. The output stages are totem-pole designs capable of sourcing or sinking in excess of 200 mA. The SG3525A output stage features NOR logic, giving a LOW output for an OFF state.


PIN CONNECTIONS

Figure-Pin-Configuration


ABSOLUTE MAXIMUM RATINGS

Symbol

Parameter

Value

Unit

Vi

Supply Voltage

40

V

VC

Collector Supply Voltage

40

V

IOSC

Oscillator Charging Current

5

mA

Io

Output Current, Source or Sink

500

mA

IR

Reference Output Current

50

mA

IT

Current through CT Terminal Logic Inputs

Analog Inputs

5

– 0.3 to + 5.5

– 0.3 to Vi

mA V V

Ptot

Total Power Dissipation at Tamb = 70 °C

1000

mW

Tj

Junction Temperature Range

– 55 to 150

°C

Tstg

Storage Temperature Range

– 65 to 150

°C

Top

Operating Ambient Temperature :  SG2525A

SG3525A

– 25 to 85

0 to 70

°C

°C


THERMAL DATA

Symbol

Parameter

SO16

DIP16

Unit

Rth j-pins

Thermal Resistance Junction-pins

Max

 

50

° C/W

Rth j-amb

Thermal Resistance Junction-ambient

Max

 

80

° C/W

Rth j-alumina

Thermal Resistance Junction-alumina (*)

Max

50

 

° C/W


BLOCK DIAGRAM

Figure-SG3525-Block-Diagram


ELECTRICAL CHARACTERISTICS

Symbol

 

Parameter

 

Test Conditions

SG2525A

SG3525A

 

Unit

Min.

Typ.

Max.

Min.

Typ.

Max.

REFERENCE SECTION

VREF

Output Voltage

Tj = 25 °C

5.05

5.1

5.15

5

5.1

5.2

V

DVREF

Line Regulation

Vi = 8 to 35 V

 

10

20

 

10

20

mV

DVREF

Load Regulation

IL = 0 to 20 mA

 

20

50

 

20

50

mV

DVREF/DT*

Temp. Stability

Over Operating Range

 

20

50

 

20

50

mV

*

Total Output Variation

Line, Load and Temperature

5

 

5.2

4.95

 

5.25

V

 

Short Circuit Current

VREF = 0 Tj = 25 °C

 

80

100

 

80

100

mA

*

Output Noise Voltage

10 Hz £f £ 10 kHz, Tj = 25 °C

 

40

200

 

40

200

mVrms

DVREF*

Long Term Stability

Tj = 125 °C, 1000 hrs

 

20

50

 

20

50

mV

OSCILLATOR SECTION * *

*, ·

Initial Accuracy

Tj = 25 °C

 

± 2

± 6

 

± 2

± 6

%

*, ·

Voltage Stability

Vi = 8 to 35 V

 

± 0.3

± 1

 

± 1

± 2

%

Df/DT*

Temperature Stability

Over Operating Range

 

± 3

± 6

 

± 3

± 6

%

fMIN

Minimum Frequency

RT = 200 KW CT = 0.1 mF

 

 

120

 

 

120

Hz

fMAX

Maximum Frequency

RT = 2 KW CT = 470 pF

400

 

 

400

 

 

KHz

 

Current Mirror

IRT = 2 mA

1.7

2

2.2

1.7

2

2.2

mA

*, ·

Clock Amplitude

 

3

3.5

 

3

3.5

 

V

*, ·

Clock Width

Tj = 25 °C

0.3

0.5

1

0.3

0.5

1

ms

 

Sync Threshold

 

1.2

2

2.8

1.2

2

2.8

V

 

Sync Input Current

Sync Voltage = 3.5 V

 

1

2.5

 

1

2.5

mA

ERROR AMPLIFIER SECTION (VCM = 5.1 V)

VOS

Input Offset Voltage

 

 

0.5

5

 

2

10

mV

Ib

Input Bias Current

 

 

1

10

 

1

10

mA

Ios

Input Offset Current

 

 

 

1

 

 

1

mA

 

DC Open Loop Gain

RL ³ 10 MW

60

75

 

60

75

 

dB

*

Gain Bandwidth Product

Gv = 0 dB Tj = 25 °C

1

2

 

1

2

 

MHz

*, ❚

DC Transconduct.

30 KW £ RL £ 1 MW Tj = 25 °C

1.1

1.5

 

1.1

1.5

 

ms

 

Output Low Level

 

 

0.2

0.5

 

0.2

0.5

V

 

Output High Level

 

3.8

5.6

 

3.8

5.6

 

V

CMR

Comm. Mode Reject.

VCM = 1.5 to 5.2 V

60

75

 

60

75

 

dB

PSR

Supply Voltage Rejection

Vi = 8 to 35 V

50

60

 

50

60

 

dB

 

Symbol

 

Parameter

 

Test Conditions

SG2525A

SG3525A

 

Unit

Min.

Typ.

Max.

Min.

Typ.

Max.

PWM COMPARATOR

 

Minimum Duty-cycle

 

 

 

0

 

 

0

%

·

Maximum Duty-cycle

 

45

49

 

45

49

 

%

·

Input Threshold

Zero Duty-cycle

0.7

0.9

 

0.7

0.9

 

V

Maximum Duty-cycle

 

3.3

3.6

 

3.3

3.6

V

*

Input Bias Current

 

 

0.05

1

 

0.05

1

mA

SHUTDOWN SECTION

 

Soft Start Current

VSD = 0 V, VSS = 0 V

25

50

80

25

50

80

mA

 

Soft Start Low Level

VSD = 2.5 V

 

0.4

0.7

 

0.4

0.7

V

 

Shutdown Threshold

To outputs, VSS = 5.1 V Tj = 25 °C

0.6

0.8

1

0.6

0.8

1

V

 

Shutdown Input Current

VSD = 2.5 V

 

0.4

1

 

0.4

1

mA

*

Shutdown Delay

VSD = 2.5 V Tj = 25 °C

 

0.2

0.5

 

0.2

0.5

ms

OUTPUT DRIVERS (each output) (VC = 20 V)

 

Output Low Level

Isink = 20 mA

 

0.2

0.4

 

0.2

0.4

V

Isink = 100 mA

 

1

2

 

1

2

V

 

Output High Level

Isource = 20 mA

18

19

 

18

19

 

V

Isource = 100 mA

17

18

 

17

18

 

V

 

Under-Voltage Lockout

Vcomp and Vss = High

6

7

8

6

7

8

V

IC

Collector Leakage

VC = 35 V

 

 

200

 

 

200

mA

tr*

Rise Time

CL = 1 nF, Tj = 25 °C

 

100

600

 

100

600

ns

tf*

Fall Time

CL = 1 nF, Tj = 25 °C

 

50

300

 

50

300

ns

TOTAL STANDBY CURRENT

Is

Supply Current

Vi = 35 V

 

14

20

 

14

20

mA


TEST CIRCUIT

Figure-SG3525-Test-Circuit

Parameter

Value

Input Voltage (Vi)

8 to 35 V

Collector Supply Voltage (VC)

4.5 to 35 V

Sink/Source Load Current (steady state)

0 to 100 mA

Sink/Source Load Current (peak)

0 to 400 mA

Reference Load Current

0 to 20 mA

Oscillator Frequency Range

100 Hz to 400 KHz

Oscillator Timing Resistor

2 KW to 150 KW

Oscillator Timing Capacitor

0.001 mF to 0.1 mF

Dead Time Resistor Range

0 to 500 W


PRINCIPLES OF OPERATION

Since both the compensation and soft-start terminals (Pins 9 and 8) have current source pull-ups, either can readily accept a pull-down signal which only has to sink a maximum of 100 µAto turn off the outputs. This is subject to the added requirement of discharging whatever external capacitance may be attached to these pins. An alternate approach is the use of the shutdown circuitry of Pin 10 which has been improved to enhance the available shutdown options. Activating this circuit by applying a positive signal on Pin 10 performs two functions : the PWM latch is immediately set providing the fastest turn-off signal to the outputs ; and a 150 µA current sink begins to discharge the external soft-start capacitor. If the shutdown command is short, the PWM signal is terminated without significant discharge of the soft-start capacitor, thus, allowing, for example, a convenient implementation of pulse-by-pulse current limiting.Holding Pin 10 high for a longer duration, however,will ultimately discharge this external capacitor, recycling slow turn-on upon release. Pin 10 should not be left floating as noise pickup could conceivably interrupt normal operation.

 

Figure-Oscillator-Schematic

 

Figure-SG3525-Output-Circuit

 

Figure-SG3525-001

 

OUTLINE AND MECHANICAL DATA

DIM.

mm

inch

MIN.

TYP.

MAX.

MIN.

TYP.

MAX.

A

 

 

1.75

 

 

0.069

a1

0.1

 

0.25

0.004

 

0.009

a2

 

 

1.6

 

 

0.063

b

0.35

 

0.46

0.014

 

0.018

b1

0.19

 

0.25

0.007

 

0.010

C

 

0.5

 

 

0.020

 

c1

45˚ (typ.)

D (1)

9.8

 

10

0.386

 

0.394

E

5.8

 

6.2

0.228

 

0.244

e

 

1.27

 

 

0.050

 

e3

 

8.89

 

 

0.350

 

F (1)

3.8

 

4

0.150

 

0.157

G

4.6

 

5.3

0.181

 

0.209

L

0.4

 

1.27

0.016

 

0.050

M

 

 

0.62

 

 

0.024

S

8˚(max.)

Figure-SG3525-SO16-Narrow

Figure-SG3525-SO16-Narrow-Dimensions

 

Datasheet PDF Download

You can download the datasheet the link given below.

SG3525-Datasheet


SG3525 FAQ

What does a pulse width modulator do?

Pulse width modulation turns a digital signal into an analog signal by changing the timing of how long it stays on and off. The term “duty cycle” is used to describe the percentage or ratio of how long it stays on compared to when it turns off.

 

What is pulse width modulator explain the types?

Pulse Width Modulation (PWM) is a fancy term for describing a type of digital signal. Pulse width modulation is used in a variety of applications including sophisticated control circuitry. A common way we use them here at SparkFun is to control dimming of RGB LEDs or to control the direction of a servo.

 

What is meant by pulse width?

From Wikipedia, the free encyclopedia. The pulse width is a measure of the elapsed time between the leading and trailing edges of a single pulse of energy. The measure is typically used with electrical signals and is widely used in the fields of radar and power supplies.

 

What is PWM in IOT?

Pulse Width Modulation (PWM) is a process of reducing distortion in a communication system. It is in use for encoding the amplitude of a signal into the tim of another signal for transmission.

 

What is unit of pulse width?

The basic unit of measure for PRF is hertz (Hz). Use PRF to report the number of pulses per second. Look at a 1 GHz clock signal as an example. The clock signal is a continuing stream of pulses at a PRF of 1 GHz.

 

Kynix

Kynix was founded in 2008, specializing in the electronic components distribution business. We adhere to honesty and ethics as our business philosophy and have gradually established an excellent reputation and credibility in our international business. With the accurate quotation, excellent credit, reasonable price, reliable quality, fast delivery, and authentic service, we have won the praise of the majority of customers.

Join our mailing list!

Be the first to know about new products, special offers, and more.

Leave a Reply

We'd love to hear from you! Feel free to share your thoughts and comments below. Rest assured, your email address will remain private.

Name *
Email *
Captcha *
Rating:

Kynix

  • How to purchase

  • Order
  • Search & Inquiry
  • Shipping & Tracking
  • Payment Methods
  • Contact Us

  • Tel: 00852-6915 1330
  • Email: info@kynix.com
  • Follow Us

authentication

Kynix

© 2008-2026 kynix.com all rights reserve.