Phone

    00852-6915 1330

MAX31865AAP+ Converter: CAD Models, Datasheet, Features [FAQ]

  • Contents

Catalog

Product Overview

MAX31865AAP+ CAD Models

MAX31865AAP+ Pin Configuration

MAX31865AAP+ Block Diagram

MAX31865AAP+ Features

MAX31865AAP+ Applications

MAX31865AAP+ Datasheet

MAX31865AAP+ Specifications

MAX31865AAP+ Manufacturer

Using Warning

MAX31865AAP+ FAQ

 

Product Overview

The MAX31865 is an easy-to-use resistance-to-digital converter optimized for platinum resistance temperature detectors (RTDs). An external resistor sets the sensitivity for the RTD being used and a precision delta-sigma ADC converts the ratio of the RTD resistance to the reference resistance into digital form. The MAX31865’s inputs are protected against overvoltage faults as large as Q45V. Programmable detection of RTD and cable open and short conditions is included.

 

MAX31865AAP+ CAD Models

MAX31865AAP+ PCB Symbol

Figure: MAX31865AAP+ PCB Symbol

 

 

 MAX31865AAP+ Footprint

Figure: MAX31865AAP+ Footprint

 

 

 MAX31865AAP+ 3D Models

Figure: MAX31865AAP+ 3D Models

 

MAX31865AAP+ Pin Configuration

MAX31865AAP+ Pin Configuration

Figure: MAX31865AAP+ Pin Configuration

 

MAX31865AAP+ Block Diagram

MAX31865AAP+ Block Diagram

Figure: MAX31865AAP+ Block Diagram

 

MAX31865AAP+ Features

  • Integration Lowers System Cost, Simplifies Design Efforts, and Reduces Design Cycle Time
  • Simple Conversion of Platinum RTD Resistance to Digital Value
  • Handles 100Ω to 1kΩ (at 0°C) Platinum RTDs (PT100 to PT1000)
  • Compatible with 2-, 3-, and 4-Wire Sensor Connections
  • SPI-Compatible Interface
  • 20-Pin TQFN and SSOP Packages
  • High Accuracy Facilitates Meeting Error Budgets
  • 15-Bit ADC Resolution; Nominal Temperature Resolution 0.03125NC (Varies Due to RTD Nonlinearity)
  • Total Accuracy Over All Operating Conditions: 0.5NC (0.05% of Full Scale) max
  • Fully Differential VREF Inputs
  • 21ms (max) Conversion Time
  • Integrated Fault Detection Increases System Reliability
  • ±45V Input Protection
  • Fault Detection (Open RTD Element, RTD Shorted to Out-of-Range Voltage, or Short Across RTD Element)

 

MAX31865AAP+ Applications

  • Industrial Equipment
  • Medical Equipment
  • Instrumentation

 

MAX31865AAP+ Datasheet

You can download the datasheet from the link given below:

MAX31865AAP+ Datasheet

 

MAX31865AAP+ Specifications

Type Description
Category Integrated Circuits (ICs)
Power Management (PMIC)
Thermal Management
Mfr Analog Devices Inc./Maxim Integrated
Package Tube
Product Status Active
Function Temp Monitoring System (Sensor)
Accuracy ±0.5°C(Max)
Topology ADC (Sigma Delta), Comparator, Register Bank
Output Type SPI
Output Alarm No
Output Fan No
Voltage - Supply 3V ~ 3.6V
Operating Temperature -40°C ~ 125°C
Mounting Type Surface Mount
Package / Case 20-SSOP (0.209", 5.30mm Width)
Supplier Device Package 20-SSOP
Base Product Number MAX31865

 

MAX31865AAP+ Manufacturer

Analog Devices (NASDAQ: ADI) is a world leader in the design, manufacture, and marketing of a broad portfolio of high performance analog, mixed-signal, and digital signal processing (DSP) integrated circuits (ICs) used in virtually all types of electronic equipment. Since their inception in 1965, they have focused on solving the engineering challenges associated with signal processing in electronic equipment. Used by over 100,000 customers worldwide, their signal processing products play a fundamental role in converting, conditioning, and processing real-world phenomena such as temperature, pressure, sound, light, speed, and motion into electrical signals to be used in a wide array of electronic devices.

 

Using Warning

Note: Please check their parameters and pin configuration before replacing them in your circuit.

 

MAX31865AAP+ FAQ

What signal does a RTD use?

An RTD delivers a special type of input signal, much like a digital or analog signal. Just as you could input a digital or analog signal into a programmable logic controller (PLC), you can input an RTD into a PLC. This would allow for the PLC to monitor temperature through the RTD.

 

Is RTD active or passive?

An RTD is a passive device. It does not produce an output on its own. External electronic devices are used to measure the resistance of the sensor by passing a small electrical current through the sensor to generate a voltage.

 

Where is RTD used?

Sometimes referred to as resistance thermometers, RTDs are commonly used in laboratory and industrial applications because they provide accurate, reliable measurements across a wide temperature range.

 

Kynix

Kynix was founded in 2008, specializing in the electronic components distribution business. We adhere to honesty and ethics as our business philosophy and have gradually established an excellent reputation and credibility in our international business. With the accurate quotation, excellent credit, reasonable price, reliable quality, fast delivery, and authentic service, we have won the praise of the majority of customers.

Join our mailing list!

Be the first to know about new products, special offers, and more.

Leave a Reply

We'd love to hear from you! Feel free to share your thoughts and comments below. Rest assured, your email address will remain private.

Name *
Email *
Captcha *
Rating:

Kynix

  • How to purchase

  • Order
  • Search & Inquiry
  • Shipping & Tracking
  • Payment Methods
  • Contact Us

  • Tel: 00852-6915 1330
  • Email: info@kynix.com
  • Follow Us

authentication