ISO124U Product Overview

ISO124U Related Video Introduction

ISO124U CAD Models

ISO124U Pin Configuration

ISO124U Simplified Schematic

ISO124U Block Diagram

ISO124U Features

ISO124U Applications

ISO124U Package Dimensions

ISO124U Datasheet

ISO124U Specifications

ISO124U Manufacturer

Using Warning

ISO124U FAQ

 

ISO124U Product Overview

A unique duty cycle modulationdemodulation approach is used in the ISO124U, a precision isolation amplifier. Digitally, the signal is sent over a capacitive barrier with a 2-pF difference. Digital modulation provides excellent reliability and good high-frequency transient immunity across the barrier since the barrier properties have no impact on the signal integrity. The plastic body of the package has embedded pieces of both barrier capacitors.

 

Using the ISO124U is simple. There are no additional parts needed for functioning. The important requirements are 0.010% maximum nonlinearity, 50-kHz signal bandwidth, and 200-µV/°C VOS drift. The ISO124U device is an excellent option for a variety of applications thanks to its quiescent currents of ±5 mA on VS1 and ±5.5 mA on VS2, as well as its ±4.5 V to ±18 V power supply range.

 

The ISO124U is available in 16-pin PDIP and 28-lead SOIC plastic surface-mount packages.

 

Video Description: We will understand basic operation of Isolation Amplifier. Types of Isolation Amplifier. Application of Isolation Amplifier.

 

ISO124U CAD Models

 

 

Figure: PCB Symbol

 

 

 

Figure: Footprint

 

 

Figure: 3D Models

 

ISO124U Pin Configuration

 

 

Figure: Pin Configuration

Pin Number Pin Name Description
28 Gnd 1 High-side ground reference
14 Gnd 2 Low-side ground reference
27 VIN High-side analog input
13 VOUT Low-side analog output
1 +VS1 High-side positive analog supply
2 –VS1 High-side negative analog supply
15 +VS2 Low-side positive analog supply
16 –VS2 Low-side negative analog supply

ISO124U Simplified Schematic

 

 

Figure: Simplified Schematic

 

ISO124U Block Diagram

 

Figure: Block Diagram

 

ISO124U Features

  • Bipolar Operation: VO = ±10 V
  • Packages: PDIP-16 and SOIC-28
  • Ease of Use: Fixed Unity Gain Configuration
  • Supply Range: ±4.5-V to ±18-V
  • 100% Tested for High-Voltage Breakdown
  • Rated 1500 Vrms
  • High IMR: 140 dB at 60 Hz
  • Maximum Nonlinearity: 0.010%

 

ISO124U Applications

  • Industrial Process Control:

– Transducer Isolator, Isolator for Thermocouples, RTDs, Pressure Bridges, and Flow Meters, 4-mA to 20-mA Loop Isolation

  • Ground Loop Elimination
  • Motor and SCR Control
  • Power Monitoring
  • PC-Based Data Acquisition
  • Test Equipment

 

ISO124U Package Dimensions

 

Figure: Package Dimensions

 

ISO124U Datasheet

You can download the datasheet from the link given below:

 

ISO124U Datasheet

 

ISO124U Specifications

Type Description
Category Integrated Circuits (ICs)
Linear
Amplifiers
Instrumentation, OP Amps, Buffer Amps
Mfr Texas Instruments
Series -
Package Tube
Product Status Active
Amplifier Type Isolation
Number of Circuits 1
Output Type -
Slew Rate 2V/μs
-3db Bandwidth 50 kHz
Voltage - Input Offset 20 mV
Current - Supply 5mA
Current - Output / Channel 15 mA
Voltage - Supply Span (Min) 9 V
Voltage - Supply Span (Max) 36 V
Operating Temperature -25°C ~ 85°C
Mounting Type Surface Mount
Package / Case 28-SOIC (0.295", 7.50mm Width), 8 Leads
Supplier Device Package 8-SOIC
Base Product Number ISO124

 

ISO124U Manufacturer

Texas Instruments Incorporated (TI) is an American technological business with its main office in Dallas, Texas. It creates and produces integrated circuits and semiconductors, which it then sells to producers and designers of electronics around the world. According to sales volume, it is one of the top 10 semiconductor businesses in the world. The company concentrates on creating embedded CPUs and analog circuits, which provide more than 80% of its sales. Calculators, microcontrollers, and multi-core processors are among the educational technology items that TI also makes using its digital light processing technology. As of 2016, the business had 45,000 patents worldwide.

 

Using Warning

Note: Please check their parameters and pin configuration before replacing them in your circuit.

 

ISO124U FAQ

What is the purpose of isolation amplifier?

In order to measure small signals while there is a high common mode voltage, isolation amplifiers are used.

 

What are the types of isolation amplifier?

There are three kinds of design methods are used in isolation amplifiers which include the following.

Transformer Isolation.

Optical Isolation.

Capacitive Isolation.

 

What is the difference between instrumentation amplifier and isolation amplifier?

The isolation amplifier's fundamental distinction from an instrumentation amplifier is. A differential stage is present in an instrumentation amplifier. An isolation amplifier has electrical isolation between its input, output, and power supply stages. The input stage of an instrumentation amplifier is present.

Kynix

Kynix was founded in 2008, specializing in the electronic components distribution business. We adhere to honesty and ethics as our business philosophy and have gradually established an excellent reputation and credibility in our international business. With the accurate quotation, excellent credit, reasonable price, reliable quality, fast delivery, and authentic service, we have won the praise of the majority of customers.

Join our mailing list!

Be the first to know about new products, special offers, and more.

Leave a Reply

We'd love to hear from you! Feel free to share your thoughts and comments below. Rest assured, your email address will remain private.

Name *
Email *
Captcha *
Rating:

Kynix

  • How to purchase

  • Order
  • Search & Inquiry
  • Shipping & Tracking
  • Payment Methods
  • Contact Us

  • Tel: 00852-6915 1330
  • Email: info@kynix.com
  • Follow Us

authentication

Kynix

© 2008-2026 kynix.com all rights reserve.