The introduction of grounding technology was originally a protective way to prevent electrical or electronic equipment from being struck by lightning. At the same time, it is also an effective means to protect personal safety. When the phase line (such as poor wire insulation, aging, etc.) touches the equipment shell for some reason, dangerous voltage will be generated on the equipment shell, thus the generated fault current will flow through the PE line to the ground, thus playing a protective role. With the development of electronic communication and other digital fields, only considering lightning protection and safety in the grounding system is far from meeting the requirements.
Electrical Grounding Explained | Basic Concepts
| 2.2 DC Power Supply Ground Analysis with Diagrams 2.3 Ground Bounce for Buck Converters |
The signal between each device needs a "ground" as the reference ground of the signal. Moreover, with the complexity of electronic equipment, the signal frequency is getting complicated. Therefore, in the grounding design, special attention must be paid to electromagnetic compatibility issues such as mutual interference between signals. Otherwise, improper grounding will seriously affect the reliability of system operation. Here the following are doubts that may arise in the power grounding.
Q1: What is the definition of grounding?
A: As for grounding concepts, to line engineers, the term usually means "reference point for line voltage". For system designers, it is often a cabinet or rack. For electrical engineers, it means green safety ground or connection to the earth. A more general definition is "A ground is a low impedance path for current to return to its source", and the key points are "low impedance" and "passage".
Q2: What are the common grounding symbols in circuit?
A:
PE, PGND, FG-protective ground or chassis
BGND or DC-RETURN-DC-48V (+24V) power supply (battery) return
GND: working ground
DGND: digital ground
AGND: analog ground
LGND: lightning protection ground
Q3: What is the appropriate grounding method?
A: There are many ways to ground, including single-point grounding, multi-point grounding and mixed types of grounding. Among them, the single is divided into series single-point grounding and parallel single-point grounding. Generally speaking, single-point grounding is used for simple circuits, while grounding distinction between different functional modules, and multi-point grounding or multi-layer boards (complete ground plane layer) are used in low-frequency (f10MHz) circuits.
Q4: Why should the analog ground and digital ground be separated?
A: Both the analog signal and the digital signal return to the ground, the digital signal changes fast with large noise, while the analog signal needs a clean ground reference to work. If the analog and digital grounds are mixed, noise can affect the analog signal.
According to the above mentioned, the analog ground and the digital ground should be processed separately, and then connected together through thin wires, or together at a single point. The general idea is to try to block the noise on the digital ground from flowing to the analog ground. Of course, this is not a very strict requirement that they must be separated, because it depends on the actual situation.
Q5: How to ground the signal on the board?
A: Under normal circumstances, it is best to use the nearest ground when designing, and after a complete multi-layer board design, it is very easy to ground common signals. The basic principle is to ensure the continuity of the traces and reduce number of vias, close to ground plane or power plane, etc.
Q6: How to ground the interface devices of the board?
A: Some single boards have external input and output interfaces, such as serial port connectors, network port connectors, etc, if they are not properly grounded, it will also affect normal work, such as network port interconnection errors, packet loss, etc., and will become an external source of electromagnetic interference, sending the noise inside the board to the outside. Generally speaking, an independent interface ground will be divided, and the connection with the signal ground will be connected by thin traces, and a o small resistance or 0ohm resistor can be connected in series. Thin traces can be used to block signal ground noise from passing to the interface ground. Similarly, the filtering of interface ground and interface power should also be carefully considered.
Q7: How to ground the shielding layer in the cable with shielding layer?
A: The layer of the shielded cable must be connected to the interface ground of the single board, not the signal ground. This is because there are various noises on the signal ground. If the shielding layer is connected to the signal ground, the noise voltage will drive the common mode current along the shielding. Therefore, cables with unreasonable design are generally the largest noise output source of electromagnetic interference.
In power supply design, safety is often in the first place, and the same is true in switching power supplies. Grounding can protect the personal safety of users and ensure the normal operation of power equipment. So what is the appropriate grounding method in switching power supplies? What are the common ground symbols in circuits? This article will popularize the grounding basic in DC power supplies.
DC-DC is a commonly used power supply circuit in electronic hardware design. It has high efficiency in realizing high input voltage and low output voltage. It is widely used, from power adapters, mobile phone chargers, and internal power conversion of electronic equipment to DC-DC circuits. Each semiconductor manufacturer has its own DC-DC chips, and also there are many optional chips. For a well-designed DC-DC circuit, not only the peripheral resistance, capacitance, but also the inductance parameters of the DC-DC circuit should be considered. There are also high requirements for the PCB layout design. This paper proposes a method to guide the grounding in the PCB layout from the perspective of the current flow in DC circuits.
Circuit grounding looks simple in a circuit schematic, but the actual characteristics of a circuit are determined by the layout of its PCB. And the analysis of the grounding point is very difficult, especially for the DC-DC converter circuit, the grounding point of the circuit will gather a large current that changes rapidly. When grounded nodes move, system performance suffers and the system radiates EMI. Here a good understanding of the physical nature of "ground" induced ground noise can provide an intuitive understanding of ground noise reduction problems.
The change of the transmission current in the ground loop will generate a magnetic field in the loop. The magnetic field strength is proportional to the current, and the magnetic flux is proportional to the product of the loop area and the magnetic field strength, which is expressed by the formula:
![]()

Figure 1. Right Hand Rule
Suppose there is a sudden break in the current loop, as shown in Figure 2. When the switch is turned off, the magnetic flux disappears, which will generate a large transient voltage along the wire. If part of the wire is a grounding return pin, the voltage referenced to the ground level will have a spike, resulting in a false signal in any circuit that uses that pin as a ground reference.

Figure 2. Function of Start Switch
The traces on the PCB circuit board are not ideal wires and have resistance. 1 ounce (oz) copper has a resistance of 500 microohms/square, so a 1 amp change in current will only produce a bounce voltage of 500uV/square -- the problem only exists if you use long thin traces or daisy chain grounds or Precision electronic circuits.
The best way to reduce ground bounce in a DC-DC switching circuit is to control the magnetic flux variation—minimizing current loop area and loop area variation. The principle of DC-DC circuit buck or boost is to use electronic switches to quickly switch to charge and discharge the energy storage element to achieve voltage conversion, and at the same time change the loop area of the current in the circuit, resulting in ground bounce and electromagnetic radiation.
In some cases, as shown in Figure, the current remains constant, while the switching causes a change in the loop area and therefore a change in the magnetic flux. In switching state 1, an ideal voltage source is connected to an ideal current source through an ideal conductor. In addition, current flows in a loop that includes a ground return.
In switch state 2, the same current flows in different paths when the switch changes position. The current source is DC and there is no change, but the loop area has changed. A change in the loop area means a change in the magnetic flux, so a voltage is generated. Because the ground loop is part of the change loop.

Figure 3. Figure Loop Area
In the case of switching changes, the loop area changes. Everywhere along the wire in the lower left, when the current I1 becomes 0, a voltage is generated where the magnetic field disappears.
The buck converter (step-down converter) circuit is very similar to the circuit structure in Figure 3 above, and the circuit of the step-down converter is simplified, as shown in Figure.

Figure 4. Step-down Converter Circuit
At high frequencies, a large capacitor such as the input capacitor Cin of the step-down converter can be regarded as a DC voltage source. Similarly, an inductor such as the output inductor LBuck can be regarded as a DC current source. These approximations help to visualize understanding and theoretical analysis.
As shown in Figure 5, when the switch alternates between the two positions, the change in the path through which the current flows causes a change in the magnetic flux. The large inductor LBuck keeps the output current approximately constant. Similarly, the large capacitor Cin holds the voltage approximately equal to Vin. Since the voltage across the input lead inductance does not change, the input current also remains approximately constant.

Figure 5. Effect of Switch on Loop Area
Although the input current and output voltage are essentially constant, when the switch is switched from position 1 to position 2, the total loop area rapidly changes by half. Loop area changes imply rapid changes in magnetic flux, causing ground bounce along the loop circuit.
In practice, a buck converter consists of a pair of semiconductor electronic switches, as shown in Figure 6. Although the complex procedure increases in each figure, the analysis method for ground bounce caused by changes in magnetic flux remains simple and intuitive.

Figure 6. Magnetic Flux Changes Cause Ground Bounce
The fact that changes in magnetic flux create voltages along the ground loop raises an interesting question: where is the real ground? Because ground bounce means that, to some ideal point called ground (that point needs to be defined), a bounce voltage is created on the ground return trace. In a power regulator circuit, the real ground should be connected to the low-voltage side of the load. After all, the purpose of a DC-DC converter is to provide a stable voltage and current to the load. All other points on the current loop are not true ground, but the part of ground loop.
Since the low-voltage end of the load is grounded and the change in the loop area is the cause of the ground bounce, then reducing the ground bounce and electromagnetic radiation, and optimizing the grounding of the circuit are to minimize the current loop area in the DC-DC circuit. Here is a way to optimize the layout. For example, the location of the input capacitor, output capacitor, and energy storage inductor reduces the current loop area. Figure shows how to carefully place the input capacitor Cin to reduce the loop area and ground bounce.

Figure 7. Reduce Ground Bounce
Capacitor Cin in Figure bypasses the high-side switch on the top layer of the PCB directly to both ends of the bottom low-side switch, thereby reducing the variation in loop area and isolating it from the ground return. When the switch switches from one state to another, from the bottom of Vin to the bottom of the load, there is no loop area change or switch current change. Therefore no ground bounce occurs in the ground loop.
Figure is an unreasonable PCB layout. When the high-side switch is turned on, the DC current flows along the red loop of the outer ring. When the low-side switch is turned on, the DC current flows along the blue loop. It can be seen that this circuit layout produces a large loop change when the switch changes, causing a change in the magnetic flux, resulting in ground bounce and electromagnetic radiation interference.

Figure 8. Unreasonable Layout
For the clarity, in single-layer PCB routing, even using a second-layer monolithic ground plane cannot solve the bounce caused by grounding. Figure 9 is a simple box to illustrate that the ground plane cannot solve the problem. Here we use a double layer PCB to add a bypass circuit at the top level power line vertical.

Figure 9. Ground Floor
In the Figure 9 (a), the ground plane is monolithic and uncut. The top layer print current flows through the capacitor, through the via, and to the ground plane. Because AC always flows along the path of least impedance, ground return current returns to the power source around the corners of its path. So when the amplitude or frequency of the current changes, the magnetic field of the current and its loop area change, thereby changing the magnetic flux. The regularity of current flow along the path of least impedance means that ground bounce can occur even with a monolithic ground plane - independent of its conduction.
In the Figure 9 (b), a properly cut ground plane limits the return current to minimize loop area, thus greatly reducing ground bounce. Any residual ground bounce voltage developed within the cut return line is isolated from the common ground plane.
The PCB layout in Figure 10 uses a double-layer PCB to mount the input capacitor and two switches on islands in the ground plane. This wiring doesn't have to be the best, but it works well and speaks to key points. It should be noted that the loop area surrounded by the red and blue currents is large, but the difference between the two loop areas is small. A small change in loop area means a small change in magnetic flux—small ground bounce. However, in general, keep the loop area small. Figure 10. is just to illustrate the importance of AC current path matching.

Figure 10. Converter Layout
Additionally, ground bounce along any ground loop is limited by ground cutting within ground loop islands where magnetic fields and loop areas vary. Also, it may appear at first glance that the input capacitance Cin is not located between the top-level high-side switch and the lower-level low-side switch shown in Figure 10. Although physical proximity can be fine, what really works is the electronic proximity achieved by minimizing the loop area.
A boost converter (step-down converter) is actually a reflection of a buck converter, as shown in Figure 11, where the output capacitor must be placed between the top high-side switch and the bottom low-side switch to minimize loop area change.

Figure 11. Changes in Loop Area
In the same way that a buck converter places Cvin at a critical position, a boost converter places Cvout at a key position.
The ground bounce voltage is mainly due to changes in the magnetic flux. In a DC-DC switching power supply, the magnetic flux variation is caused by switching the DC current at high speed between different current loop areas. But careful placement of the buck converter's input capacitors and the boost converter's output capacitors, and a good cut of the ground plane can isolate ground bounce. Pay attention to, it is important to be careful when cutting the ground plane to avoid increasing the loop area for other return currents in the circuit.
Another reasonable layout should place the real ground on the bottom layer connecting the load, which will not cause changes in loop area or current. Any other point related to conduction can be called "ground", but it's just a point along the return path.
If you follow the basic concepts, you will have a clear idea of what will cause ground bounce. Figure 12. shows that two conductors that are perpendicular to each other are not subject to the mutual influence of the magnetic field.

Figure 12. Two Conductors Perpendicular to Each Other
The magnetic field lines created around two parallel wires carrying equal currents in the same direction traditionally cancel each other out between the two wires, so the total energy stored by the two wires is less than the energy stored by one wire alone. Therefore, the inductance of PCB wide traces is smaller than that of narrow traces.

Figure 13. Two Parallel Wires with Current Flowing in Same Directions
The magnetic field lines generated around two equal conductors carrying equal currents in opposite directions cancel each other out of the two conductors, and strengthen between the two conductors. If the inner loop area is reduced, so does 4the total magnetic flux. This phenomenon can explain why the return current of the AC ground plane always flows under the trace conductors on the top layer of the bath.

Figure 14. Two Parallel Wires with Current Flowing in Opposite Directions
Figure 15. shows why corners add inductance. A straight wire only sees its own magnetic field, but at the corners, the magnetic field of a vertical wire is also visible. Therefore, the corners store more magnetic field energy, and their inductance is greater than that of straight wires.

Figure 15. Add Inductance at the Corners
Figure 16. shows that cutting the ground plane under the transmission line conductor increases the loop area by diverting the loop current, thereby increasing the loop size and contributing to ground bounce.

Figure 16. Return Current Flows Along the Path of Least Impedance

Figure 17. Effect of Component Orientation
Ground bounce has always been a potential problem. For monitors or TVs, it means the image is noisy, for audio equipment it means the noise floor. In digital systems, ground bounce can cause calculation errors -or even system crashes. Careful estimation of parasitic elements and simulation are effective methods for predicting the magnitude of ground bounce.
First, when designing the PCB, the low-voltage side of the load should be set to true ground. Then, replace the large inductors and capacitors with current and voltage sources to simplify the circuit dynamics. Observing the current loop under each switch combination, the loops should be made to overlap, and if this is not possible, an island should be carefully cut out in the ground plane to ensure that only islands of DC inflow and outflow are present.
In most cases, good grounding performance can be obtained with these efforts. If that doesn't work, the resistance of the ground plane should be considered first, then the displacement currents flowing across all switches and parasitic capacitors entering the return path. In short, no matter what circuit, the principle is the same, that is, to reduce the loop area and its difference when the switch changes.
1. Does power supply need to be grounded?
While it will likely be fine (I've run many computers in old houses that had no grounding), it's not advised. A static charge will build up, and depending on where it discharges may cause damage to the electronics.
2. What is the purpose of a ground wire?
The ground wire offers an additional path for the electrical circuit to flow into the earth so as to not endanger anyone working with the electricity nearby in the event of a short circuit. Without ground wire, your body could instead complete the ground path and may cause shock or electrocution.
3. Which wire is ground on power supply?
In a DC circuit, the convention in most of the world is that black is the “ground” and any other color carries a signal or power rail of some sort, with red and yellow being popular for power wiring, but it can really be any color on any particular connector. For example, for a typical PC “ATX” power supply.
4. What is the purpose of a ground?
Grounding gives electricity the most effective way to return to the ground via your electrical panel. A grounding wire gives an appliance or electrical device a safe way to discharge excess electricity.
5. Should you ground the negative of a DC power supply?
As long as both the negative terminal of the LED and the negative terminal of the battery both have good enough connections to ground then the ground will carry enough current between the two connection to complete the circuit and light the LED. The same applies in the mains electricity supply.
6. How do I know if my power supply is grounded?
Insert one probe of the circuit tester into the small slot and the other probe into the large probe. If the circuit tester lights up, you have power to the outlet. Now place one probe in the small slot and the other probe into the "U" shaped ground hole. The indicator should light up if the outlet is grounded.
7. Can you ground yourself by touching PSU?
It looks pretty, but it's impossible to ground yourself to a case that has no bare metal. Instead, I just installed my power supply and touched the ground prong every now and then. All that said, if all you're doing is touching a metal part on the computer, you aren't really grounding yourself.
8. Can I tie the neutral and ground together?
No, the neutral and ground should never be wired together. This is wrong, and potentially dangerous. When you plug in something in the outlet, the neutral will be live, as it closes the circuit. If the ground is wired to the neutral, the ground of the applicance will also be live.
9. What is ground in DC circuit?
Traditionally, "ground" is the lowest potential in a circuit, e.g. the minus side of a battery or DC supply.
10. What happens when electricity goes to ground?
The majority of the energy of the lightning discharge is dissipated in the air as it travels from the clouds to the ground through the air. The remainder is dissipated in the ground in the area surrounding the location of the strike, over a fairly short distance.
11. What is difference between earthing and grounding?
Earthing and grounding are similar terms. ... The main difference between earthing and grounding is that the earthing refers that the circuit is physically connected to the ground with Zero Volt Potential. But, grounding refers that the circuit is not physically connected to ground, but still has zero potential.
12. Does a DC power supply need a ground?
The answer comes from the NEC section 250.162, referring to the grounding of two-wire DC systems, which includes the 5V and 24V outputs, depending on your case. ... So, the short answer for a 24V DC system is no, the output is not required to be connected to ground.
13. How do you ground a DC power supply?
You ground the device by connecting a grounding cable to earth ground and then attaching it to the grounding point on the DC power supply. You must provide the grounding cables. The cable lug used on the grounding cable should have a #10 stud hole and accommodate a minimum of 12-AWG wire.
Ivy is a seasoned writer with over 6 years of experience in the semiconductor electronics industry. She possesses a wealth of knowledge in the field, coupled with cutting-edge creative concepts. Ivy is a distinguished author with unique insights and a remarkable writing style.